UK - Manual installation, use and maintenance.
210-0203_Libretto_SX-ind_ATI_2021-02_GB.docx
11
Ed 2021-02
12.
INSTALLATION
OPERATION CARRIED OUT BY A QUALIFIED
Warning! The installation of the residential ventilation system must be performed only by qualified personnel in order to avoid
damage or injury.
Before installing the appliance, ensure that the nominal supply voltage is 220 / 240V - 50 / 60Hz.
Make sure that the electrical system is adapted to deliver, in addition to the operating current required by the unit, also
the necessary current for powering appliances and equipment already in use.
Make the electrical connections in accordance with national laws and regulations.
Upstream of the unit to provide a single-pole switch with a minimum distance of 3.5 mm contacts.
The installation of the device is divided into 6 distinct phases, listed below, to be followed with attention and respecting the
order.
1.
Positioning device
2.
fume extraction hood Installation
3.
Installing flue
4.
Water connections
5.
Connection gas circuit
6.
Electrical connection
You should always make the grounding of the unit. Check that the power cord is in perfect condition. Under no circumstances
must repair the cable, possibly damaged, with tape or clamps. If the power cord is damaged, it must be replaced by service
agent or a similarly qualified person in order to avoid a hazard.
Incorrect installation can cause damage to people and things for which the manufacturer can not be held responsible.
13.
POSITIONING APPARATUS
The location of the device must be chosen bearing in mind the maximum length allowed for each type of discharge, gas and
electrical connection. The device has been designed to have the water connections, electrical and gas to the right of the
appliance and the flue above: it is recommended to place the heater in such a way as to facilitate the installation and
maintenance operations.
Since the C-type unit, this unit can be installed in any type of local, without any limitation on aeration conditions and volume of
the room.
Refer to the clearances required as in the figure below.
The front and right of the appliance must be easily accessible, in order to facilitate proper installation and periodic maintenance.
To prevent possible infiltration of water during a thunderstorm, we recommend a slight downward slope of the drain pipe and
air suction.
IMPORTANT:
FOLLOW THE EXTENT TO INSTALL NATIONAL STANDARDS.