DIAGNOSTIC TOOL
The red light in the reset button is able to indicate the type of error. The light switches on intermittently according to the type of
burner ignition impediment, with a series of pulses and a pause of 2s between one series and the next.
ERROR DIAGNOSTIC TABLE
Type of signal
Mistake
0 ON
There are no errors
2 ON ••
The ignition cycle does not occur due to failure to close the pressure switch
3 ON •••
The ignition cycle does not occur due to a glued pressure switch (closed without fan)
Steady on
Water heater blocked due to burner ignition failure
To solve problems related to intermittent signals, check the fan and pressure switch. To unblock the appliance from the fixed
light, check the gas and / or burner circuit and press the reset button for 2 seconds to unlock the appliance and repeat the
ignition cycle.