UK - Manual installation, use and maintenance.
210-0203_Libretto_SX-ind_ATI_2021-02_GB.docx
15
Ed 2021-02
AKIT21 and AKIT24 diaphragm mounting
AKIT22 diaphragm assembly
According to the model of the appliance and the length of the suction pipe, install the diaphragm shown in the table.
AKIT21
AKIT22
AKIT24
1 m
2 m
3 m
1 m
2 m
3 m
4 m
5 m
6 m
1 m V
1 m H +
1 m V
1 m H +
2 m V
1 m H +
3 m V
1 m H +
4 m V
SX160
Ø84
Ø86
-
Ø40
Ø42
Ø44
Ø44
Ø44
no
Ø82
Ø82
Ø82
Ø82
Ø84
SX220
Ø82
Ø86
-
Ø42
Ø46
Ø46
Ø48
Ø50
no
Ø82
Ø84
Ø84
Ø90
Ø92
SX300
Ø82
Ø86
-
Ø45
Ø45
Ø45
Ø45
Ø45
no
Ø82
Ø84
Ø83
Ø84
Ø84
SX400
-
-
-
Ø48
Ø48
Ø52
Ø56
Ø56
no
no
no
no
no
no
SX600
Ø82
Ø86
-
Ø44
Ø44
Ø44
Ø44
Ø44
no
Ø78
Ø78
Ø80
Ø80
Ø80
SX800
Ø82
Ø82
-
Ø38
Ø38
Ø40
Ø40
Ø50
Ø58
Ø78
Ø80
Ø80
Ø82
Ø82
AKIT25, AKIT26 diaphragm mounting
AKIT25
AKIT26
1 m
2 m
3 m
4 m
5 m
6 m
+ 1.5m
H + 5m
V
+ 3m H
+ 5m V
+ 6m H
+ 1m V
+ 6m H
+ 2m V
+ 6m H
+ 3m V
+ 6m H
+ 4m V
+ 6m
H +
5m V
SX160
Ø44
Ø44
Ø46
Ø44
Ø44
Ø48
Ø48
Ø48
Ø48
Ø48
Ø48
Ø48
Ø48
SX220
Ø46
Ø46
Ø48
Ø48
Ø48
Ø48
Ø48
Ø48
Ø52
Ø52
Ø52
Ø52
Ø52
SX300
Ø48
Ø48
Ø50
Ø50
Ø50
Ø50
Ø50
Ø52
Ø52
Ø52
Ø52
Ø52
Ø52
SX400
Ø50
Ø50
Ø50
Ø52
Ø52
Ø54
Ø54
Ø54
Ø54
Ø54
Ø54
Ø54
Ø54
SX600
Ø42
Ø42
Ø42
Ø44
Ø44
Ø44
Ø44
Ø44
Ø44
Ø44
Ø44
Ø44
Ø44
SX800
Ø38
Ø38
Ø40
Ø42
Ø42
Ø44
Ø44
Ø44
Ø44
Ø44
Ø44
Ø44
Ø44
IMPORTANT:
DURING THE INSTALLATION OF THE KIT AKIT24, AKIT25,
AKIT26, THE SPECIAL CONDENSATE DRAIN CONNECTION
MUST BE CONNECTED TO A CLEAR WATER DRAIN.
At the end of the operation, carefully check all the seals of the
ducts for the evacuation of the combustion products and the
air intake.