Manual, F/T Sensor, Serial Axia
Document #9610-05-Serial Axia-05
Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 • Tel:+1 919.772.0115 • Fax:+1 919.772.8259 •
49
5.6 Peak Reset Command: “peak reset”
The highest and lowest values of F
x
\ F
y
\ F
z
\ T
x
\ T
y
\ T
z
that occurred for a run-time and all-time can be
set to the following values by using the “peak reset” command.
“peak reset” command format:
user:
peak reset
response:
F/T Units RunPeak- AllPeak-
--- ----- -------- -------- -------- --------
Fx N 2147.484 -2147.484 -750.000 750.000
Fy N 2147.484 -2147.484 -750.000 750.000
Fz N 2147.484 -2147.484 -1350.000 1350.000
Tx Nm 2147.484 -2147.484 -30.000 30.000
Ty Nm 2147.484 -2147.484 -30.000 30.000
Tz Nm 2147.484 -2147.484 -30.000 30.000
5.7 Save All Command: “saveall”
The “saveall” command records all values that remain through a power cycle to NVM.
“saveall” command format:
user:
saveall
response:
Parameters saved to NVM bank 0
Parameters saved to NVM bank 1
5.8 Set Command: “set”
The “set” command reports all parameters. In some cases, the user can also write these parameters. These
parameters are listed in
“set” command format:
user:
set
response:
Field
Value
-----
-----
serialNum
FT22835
partNum
SI-500-20
calFamily
NET
...
To read a stored parameter in NVM for a field from
For example:
user:
set cpf
response:
Field
Value
-----
-----
cpf
100000