QSG_ERD620_421.00_EN_01 / 2020-09-09
8
/
48
Indirect measurement
The indirect measurement (also called recovery mode or under bell) allows a considerable
gain in time as the flow which enters into the device is already stabilized.
The test pressure is first applied to the input of the part under test
1
and then to the
device
2
. The output of the device
2
is vented to the atmosphere.
This method allows to test the parts at a higher pressure test (up to 2 MPa).
1
Part under test
2
Device
Depending on the part type, it may be possible to use a bell (ex: shower head where
it is impossible to recover the flow other than through the use of a bell). This method can
only be used if the recovery of the flow is easy.
PRINCIPLE OF A CYCLE
The measurement cycle is made of 4 main phases: fill, stabilization, test, dumping.
A Pressure auto zero additional phase
0
can be placed at the start or at the end of a cycle,
depending on the requirement of the operator.
0
Pressure auto zero phase (optional)
1
Flow auto zero (0.8s) + Pressure up
time
2
Flow auto zero (0.8s) + Step time
3
Pressure down time
0
Pressure auto zero phase (optional)
1
Pressure up time
2
Step time
3
Pressure down time