PN0108 User Manual
70
Administrator Login Failure
If you are unable to perform an Administrator login (because the Username and
Password information has become corrupted, or you have forgotten it, for
example), you can clear the login information with the following procedure:
1. Power off the PN0108 and remove its cover.
2. Short the jumper labeled J4.
3. Power on the switch.
4. Wait 5 seconds, then power off the switch.
5. Remove the jumper cap from J4.
6. Close the housing and start the PN0108 back up.
After you start back up, you can use the default Username and Password to
log in (see page 70).