PN0108 User Manual
50
Manual Setup
Windows NT, 2000, XP, and Server 2003 can be manually configured for safe
shutdown and rebooting instead of using the
Power Monitor
utility. The
following sections explain the procedures involved.
Windows 2000 / XP / Server 2003:
To set up Windows 2000, XP, or Server 2003 for safe shutdown and rebooting,
do the following:
1. Go to the Control Panel; open
Power Options
; open the
UPS
page; in the
Details panel, click
Select
. A dialog box similar to the one below appears:
a) For the COM port entry, select the COM port on the computer that the
Safe Shutdown Cable is plugged into.
b) Match the other options to the values shown in the figure above.