11. TROUBLESHOOTING GUIDE
Here are some recommendations for solving urgent problems. If the trouble cannot be
solved, or if you have a problem other than those described hereunder, please contact
our technical service or your nearest dealer.
TROUBLE
CAUSES
REMEDY
Low surface quality (at
aluminum and similar
materials):
Rough surface,
Large chip,
Not homogenous surface,
Saw blade traces visible
Not cooling the saw blade
surfaces
Lubricating the saw blade cutting
surfaces,
Using of cooling liquid
Using of damaged or blunt
saw blade
Check the saw blade teeth.
Replace if necessary.
Saw blade moves to quick
The cutting speed is too high for
the material. Decrease the cutting
speed.
Motor does not work (Start
button is pressed, not
working)
No power supply to the
machine. Main Switch is in
“0” position.
The upper protective cover
or the front cover is open.
Check the electric cable
connections.
Check the electric power sockets.
Switch the Main Switch to “I”.
Close the upper cover and the
front cover.
Motor is working but the
pneumatic clamp pistons do
not work.
The air supply connections
are missing, or the air
pressure is below 4 Bar.
Check the air compressor
connections.
Adjust the air pressure between 6-
8 Bar on the conditioner.
The saw blade rotates in
reverse direction.
The electric connection,
the power cable or the
connection at the panel is
wrong.
Let the electric connections carry
out by a qualified electrician.
NOISE EMISSION
Material: Aluminum Extrusion 1,220 mm (l) x 70 mm (w) x 20 mm (h)
LWA: 96 dB (measured value)
K: 2 dB (tolerance at measuring) EN ISO 3744 Standard