MAINTENANCE
Once a faulty CP is identified, it can be replaced using the procedures in
“Reseating and Replacing Circuit Packs” under “Routine Maintenance. ”
Refer to the information in “Circuit Pack LEDs” under the “General
Maintenance Information” to understand the meaning of the CP LEDs.
.
If the Error Log notes an error related to the touch-tone receivers, the
receivers are performing below system requirements.
Touch-tone receiver problems are due to a faulty Service Circuit (ZTN85 or
ZTN131 [R3]) or Tone Detector (TN748). Replace the faulty CP.
Frontplane Ribbon Connector Trouble (Release 1 Only)
The frontplane ribbon connector is a flat cable connecting the Call Processor
and Memory CPs at their front edges.
To reattach or replace this cable, follow these steps:
1.
Remove power from the system.
2. Pull the exposed tab on the cable from one of the CPs. This
exposes a second tab at the other end of the cable.
3. Pull the second tab to remove the cable entirely.
4.
Replace the cable in the reverse manner. (The cable is keyed for
correct placement.)
Power Supply Trouble
If a major malfunction occurs, the system may activate the 109 Emergency
Transfer Unit. With this condition, the system may be nonfunctional, even
though the green LEDs on CPs in the other cabinets remain lighted. Failure
of the power supply in a cabinet containing only port CPs (Cabinet 2 or 3) will
shut down all devices connected to that cabinet but will not shut down the
entire system.
Check the green LED on PS (visible through the fan slots on the front door).
If extinguished, PS is shut down.
Remove ac power from the cabinet for
about 3 minutes. Turn on ac power. Green LED lighted, PS overheated (fan
defective), or current overload. Check all boards in cabinet for problems.
4-64
Содержание Network Adapter 25
Страница 1: ...AT T AT T System 25 Installation and Maintenance Manual 555 540 103 B November 1995 ...
Страница 18: ...APPENDIX F Administration Error Messages GLOSSARY I N D E X F 1 G 1 I 1 viii ...
Страница 29: ...INSTALLATION NOTE 9 WIDE MOUNTING CENTERS ARE 8 1 2 APART FLANGES OVERLAPPED Figure 2 1 10B ETU 2 5 ...
Страница 31: ...INSTALLATION MOUNTING CENTERS WHEN FLANGES ARE OVERLAPPED Figure 2 2 617A Panel 2 7 ...
Страница 33: ...INSTALLATION Z21OA1 ADAPTER Y ADAPTER WP90851 L1 858A ADAPTER Figure 2 3 SIP Adapters 2 9 ...
Страница 50: ...INSTALLATION Figure 2 10 Three Cabinet System Front View With Covers Removed 2 26 ...
Страница 51: ...INSTALLATION Figure 2 11 Position of Shorting Plugs on CPU Memory Circuit Pack 2 27 ...
Страница 72: ...INSTALLATION UPPER ADAPTER MOUNTING CLIP Figure 2 18 Mounting Adapters ...
Страница 85: ...INSTALLATION 2 61 ...
Страница 92: ...INSTALLATION 2 68 ...
Страница 103: ...INSTALLATION Figure 2 32 10B Emergency Transfer Unit 2 78 ...
Страница 104: ...INSTALLATION Figure 2 33 Emergency Transfer Unit Connections 2 79 ...
Страница 109: ...INSTALLATION Figure 2 35 Attendant Console With DXS Console 2 84 ...
Страница 146: ...INSTALLATION 2 119b This page intentionally left blank November 1995 ...
Страница 153: ...INSTALLATION This page intentionally left blank 2 124b November 1995 ...
Страница 156: ...Figure 2 57 278A Adaptor Plug Positions for Connecting TN763 Circuit Pack to Paging System 2 127 ...
Страница 223: ...MAINTENANCE Figure 4 2 Clearing Supply Troubles Sheet 1 of 2 4 47 ...
Страница 224: ...MAINTENANCE Figure 4 2 Clearing Power Supply Troubles Sheet 2 of 2 ...
Страница 225: ...MAINTENANCE Figure 4 3 Clearing CO Trunk Troubles 4 49 ...
Страница 226: ...MAINTENANCE Figure 4 4 Clearing 4 Wire Tie Trunk Troubles Sheet 1 of 4 4 50 ...
Страница 227: ...MAINTENANCE Figure 4 4 Clearing 4 Wire Tie Trunk Troubles Sheet 2 of 4 4 51 ...
Страница 228: ...MAINTENANCE Figure 4 4 Clearing 4 Wire Tie Trunk Troubles Sheet 3 of 4 4 52 ...
Страница 229: ...MAINTENANCE Figure 4 4 Clearing 4 Wire Tie Trunk Troubles Sheet 4 of 4 4 53 ...
Страница 231: ...Figure 4 6 Clearing Tie Trunk Troubles Sheet 1 of 5 4 55 ...
Страница 232: ...MAINTENANCE 6 7 8 9 10 Figure 4 6 Clearing Tie Trunk Troubles Sheet 2 of 5 4 56 ...
Страница 233: ...MAINTENANCE Figure 4 6 Clearing Tie Trunk Troubles Sheet 3 of 5 4 57 ...
Страница 234: ...MAINTENANCE Figure 4 6 Clearing Tie Trunk Troubles Sheet 4 of 5 4 58 ...
Страница 235: ...MAINTENANCE Figure 4 6 Clearing Tie Trunk Troubles Sheet 5 of 5 4 59 ...
Страница 236: ...MAINTENANCE Figure 4 7 Clearing Paging Equipment Troubles ...
Страница 250: ...MAINTENANCE Figure 4 9 System Cabinet Backplane Wiring Side Sheet 2 of 2 4 74 ...
Страница 251: ...MAINTENANCE Figure 4 10 TDM Signal Designations on Cabinet Backplane 4 75 ...
Страница 252: ...MAINTENANCE Figure 4 11 Power Designations on Cabinet Backplane 4 76 ...
Страница 263: ...MAINTENANCE Figure 4 12 Clearing Virtual Facilities Troubles Sheet 1 of 3 ...
Страница 264: ...MAINTENANCE Figure 4 12 Clearing Virtual Facilities Troubles Sheet 2 of 3 4 87 ...
Страница 265: ...MAINTENANCE Figure 4 12 Clearing Virtual Facilities Troubles Sheet 3 of 3 4 88 ...
Страница 271: ...MAINTENANCE Figure 4 13 Clearing Switched Loop Attendant Console Troubles Sheet 1 of 5 ...
Страница 272: ...MAINTENANCE 4 13 Clearing Switched Loop 2 of 5 Console Troubles Sheet 4 95 ...
Страница 273: ...MAINTENANCE Figure 4 13 Clearing Switched 3 of 5 Loop Attendant Console Troubles Sheet 4 96 ...
Страница 274: ...MAINTENANCE 4 13 Clearing Switched 4 of 5 Console Troubles 4 97 ...
Страница 305: ...APPENDIX C System Additions or Changes Figure C 1 Typical System 25 Port Circuit Pack C 4 November 1995 ...
Страница 321: ...APPENDIX E Administration Codes and Data This page is intentionally blank E 2 b ...
Страница 341: ...APPENDIX E Administration Codes and Data Table E J MET Set Button Defaults Cannot be changed E 22 ...