2003
(TRIP_PRTY)(tr), MAJOR
TRIP: TDM Parity Error Detected On Channel <channel>
And Time Slot <integer>
This error should not be generated.
•
Call the NSSC or NSAC.
2004
(TRIP_OVFL)(tr), MAJOR
TRIP: Tip/Ring Event Lost, Base <device>, lines <integer>
Too many simultaneous events have occurred on the indicated boards
for the Voice System to process. DATA HAS BEEN LOST,
affecting service to callers on one or more channels. System load
may be too heavy.
•
If error continues, reboot the system.
2005
(TRIP_SBRK)(tr), MAJOR
TRIP: Break in <string> detected on channel <channel>
A gap has been detected during a coding or voice output session.
Either the customer-coded voice is incomplete or the voice that the
customer heard contained inappropriate silence.
This condition typically is related to excessive load on the system
controller. This error typically appears at the same time as errors 591
(VROP_PLAY_TMOUNT) or 592 (VROP_CODE_TMOUNT).
These indicate the same condition.
2009
(TRIP_CLIP), STATUS
This error indicates that the output signal level on a Tip/Ring
Channel approached the level deemed too loud for the Telephone
Network by the FCC. The output signal was thus interrupted until
the output signal level dropped below the threshold of
noncompliance.
A-36 APPENDIX: System Messages
Содержание 6386 WGS
Страница 1: ...AT T 999 500 355 Issue 1 July 1990 AUDIX Voice Power Installation and Maintenance Guide...
Страница 14: ......
Страница 37: ...FIGURE 2 19 Location of Memory SIMM Sockets on 6386 25 WGS Hardware Installation 2 23...
Страница 54: ...FIGURE 2 30 VDC600 Switch and Jumper Locations and Settings 2 40 Hardware Installation and Maintenance...
Страница 61: ...FIGURE 2 38 6386E 33 WGS System Module Back Panel Hardware Installation 2 47...
Страница 112: ......
Страница 124: ......
Страница 134: ......
Страница 205: ......
Страница 209: ......