VI-GAS CONNECTION
Gas connections of the device;
should be performed by an expert technician.
The person to carry out the gas connection should perform the connection in accordance with
the rules specified by the local energy supplying company in relative country.
Attention
; maximum gas pressure that may be applied while the device is running is 50 mbar.
There may be gas leakage risk at pressures more than 50mbar. In such cases
the device
may fail and fall outside the scope of the warranty.
Gas inlet is on the right side from frontal view.
See Page 7 (Image -3)
If you plan to use LPG tube hose connection to the device is required. As shown in Image -3.
(hose inlet is supplied with the device)
Image -3
VII- OPERATION
- Pilot operation
Turn the gas control knob to pilot position and press for 10-15 seconds. Start the pilot fire by
striking the igniter and the pilot is ignited when pilot fire burns for 20-25 seconds. Then remove your finger
from the gas tap and start using the device. When the pilot fire is extinguished repeat the whole process
from the beginning.
- Ignition
Normal Fire:
Low Fire:
- Turning Off
Press on the gas tap and turn the knob to “ ● “ position.
NOTE
You may check whether the device is ignited or not
from the loop hole while the device is operating.
In addition, when the igniter is not in use, you may check
from the loop hole and fire using spirit stick.