Air vents in the lower kitchen cabinet
•
Normal operation of the induction cooking hob electronic components requires sufficient air
circulation.
Lower cabinet without an oven
•
There must be an opening with a height of
no less than 140 mm along the entire width
of the cabinet in the cabinet rear wall. In
addition, there should be an opening of at
least 6 mm in the front side, along the
entire width of the cupboard.
•
A horizontal partition panel should be
installed underneath the induction hob
along its entire length. There should be at
least 20 mm of clearance between the
lower end of the appliance and the
partition panel. Adequate ventilation
should be allowed from the rear side.
•
The hob is fitted with a fan located in its lower part. If there is a drawer underneath the countertop,
do not use it to store small objects or paper as these could, if sucked into the fan, damage the
fan and the cooling system. Moreover, do not use the drawer to store aluminium foil or flammable
substances or liquids (such as sprays). Keep such substances away from the cooking hob.
Danger of explosion! There should be at least 20 mm of clearance between the contents of the
drawer and the fan inlet vents.
Lower cabinet with an oven
•
Only install ovens with a cooling fan under
the induction hob. Before installing the
oven, the kitchen cabinet rear wall has to
be removed in the area of the opening for
installation. In addition, there should be an
opening of at least 6 mm in the front side,
along the entire width of the cabinet.
•
If other appliances are installed under the
induction cooking hob, we cannot
guarantee their correct operation.
47
Installation