8
Connect Home & Limit Sensors
Connect Servo Motor and Drive.
ü
All cables should be connected with their own devices. (See the serial numbers)
ü
When you use only one Servo Axis, make sure to connect CN1 to SVCN1 on
OACIS
.
If the noise signal levels are high due to the unexpected electric interference,
it can work to clamp a ferrite with U, V and W wires together
.
SERVO MOTOR
SERVO DRIVE
V
W
B
U
M
POWER CABLE
SERVO MOTOR
0VDC
SERVO DRIVE
FERRITE
+24VDC
LIMIT SENSOR
(PROXIMITY SENSOR)
BROWN-24V
BROWN-24V
BLACK
-Sensing Signal
HOME SENSOR
(CONTACT SENSOR)
BLUE-0V
BLUE-HOME
Home sensor cable should be connected with power off.
LIMIT SENSOR
(PROXIMITY SENSOR)
HOME SENSOR
(CONTACT SENSOR)
Содержание OACIS-2XC
Страница 10: ...10...
Страница 12: ...12 Servo Drive...
Страница 20: ...20 Homing Select OPERATING tab on the Command window...