Asycube 240
Operating Manual
000.100.500
Version: A6
Asycube 240
17/52
Power connection
WARNING !
-
Before supplying power to the Asycube, check that your distribution voltage is the same as
the nominal voltage.
-
Never disconnect the power cables. Always turn the machine off and then cut the power
-
Use PELV (protected extra-low voltage) nominal voltage
Pin
Signal description
Cable
(option)
(1)
24VDC PELV
S-Power
1
(2)
0V GND S-Power
2
(3)
24VDC PELV
Power
3
(4)
0V GND Power
4
(5)
EARTH
PE
Connector type (on Asycube side) :
M16, 5 Poles, male
In case of all functions working
simultaneously
(vibration,
backlight,
outputs), the current increases to 8A.
Characteristic
Value
Voltage
+24V DC + 5%
Current Power
5A max.
Current S-Power
3A max.
Figure 2-9 : power connection
NOTE:
S-Power is the safety power for the backlight. Cutting this S-Power ensures that the
backlight stays OFF (e.g. to secure IR backlight danger).
The following connection schematic shows the way to connect the asycube depending if
your application requires using an external relay to ensure that the backlight is safely
switched off or not.
In any case, both “Power” and “S-Power” have to be supplied for using the backlight.