Digital input 1 and 2
2.4.5.
A standard M8 three-pins male cable
enables to read two different signal , it
must be connected as follows :
Pin
Signal
(1)
+24VDC
OUT
(sensor
power supply)
(3)
0V GND
(4)
Input (+24VDC)
Connector type (on asycube side) :
M8, 3P, female
Figure 2-12 : Digital input
Digital output for hoppers 1 and 2
2.4.6.
A standard M8 four-pins male cable
enables to transmit digital output signal
and analog output signal to hopper. It
must be connected as follows :
Pin
Signal
Hopper
(1)
0V GND
Analog Output 1
(2)
0…10VDC
(3)
0V GND
Digital Output 1
(4)
+24VDC
Connector type (on asycube side) :
M8, 4P, female
Figure 2-13 : Digital output for hoppers