Power connection
2.4.2.
WARNING !
-
Before supplying power to the Asycube, check that your distribution voltage is the same
as the nominal voltage.
-
Never disconnect the power cables. Always turn the machine off and then cut the power
-
Use PELV (protected extra-low voltage) nominal voltage
Pin
Signal description
(1)
24VDC PELV
S-Power
(2)
0V GND S-Power
(3)
24VDC PELV
Power
(4)
0V GND Power
(5)
EARTH
Connector type (on asycube side) :
M16, 5 Poles, male
In case of all functions working
simultaneously (vibration, backlight,
outputs), the current increases to 8A.
Characteristic
Value
Voltage
+24V DC + 5%
Current Power
5A
Current S-Power
3A
Figure 2-9 : power connection
WARNING !
-
S-Power is the safety power. This 24V is the power supply of backlight and digital
outputs. Cutting this 24V permits to be sure that the backlight and the outputs
stay OFF (e.g. to secure IR backlight danger). As a consequence, you must get a
24V signal on the S-Power to be able to use the backlight.