background image

ASUS TS100-E8-PI4

This chapter includes the motherboard layout 
and  brief  descriptions  of  the  jumpers  and 
internal connectors.

Chapter 3

Motherboa

rd Info

Содержание TS100E8PI4

Страница 1: ...Pedestal Server TS100 E8 PI4 User Guide ...

Страница 2: ...ption of business and the like even if ASUS has been advised of the possibility of such damages arising from any defect or error in this manual or product Specifications and information contained in this manual ae furnished for informational use only and are subject to change at any time without notice and should not be construed as a commitment by ASUS ASUS assumes no responsibility or liability ...

Страница 3: ... LEDs 1 8 Chapter 2 Hardware setup 2 1 Chassis cover 2 2 2 1 1 Removing the side cover 2 2 2 1 2 Reinstalling the side cover 2 3 2 2 Central Processing Unit CPU 2 4 2 2 1 Installing the CPU 2 4 2 2 2 Installing the CPU heatsink and fan 2 7 2 2 3 Uninstalling the CPU heatsink and fan 2 8 2 3 System memory 2 9 2 3 1 Overview 2 9 2 3 2 Memory Configurations 2 9 2 3 3 Installing a DIMM 2 10 2 3 4 Remo...

Страница 4: ...program 4 7 4 2 1 BIOS menu screen 4 8 4 2 2 Menu bar 4 8 4 2 3 Menu items 4 9 4 2 4 Submenu items 4 9 4 2 5 Navigation keys 4 9 4 2 6 General help 4 9 4 2 7 Configuration fields 4 9 4 2 8 Pop up window 4 9 4 2 9 Scroll bar 4 9 4 3 Main menu 4 10 4 3 1 System Date 4 10 4 3 2 System Time 4 10 4 4 Advanced menu 4 11 4 4 1 CPU Configuration 4 12 4 4 2 PCH IO Configuration 4 15 4 4 3 SATA Configuratio...

Страница 5: ... 2 5 1 1 RAID definitions 5 2 5 1 2 Installing hard disk drives 5 3 5 1 3 Setting the RAID mode in BIOS 5 3 5 1 4 RAID configuration utilities 5 3 5 2 Intel Rapid Storage Technology enterprise SATA Option ROM Utility 5 4 5 2 1 Creating a RAID set 5 5 5 2 2 Deleting a RAID set 5 7 5 2 3 Resetting disks to Non RAID 5 8 5 2 4 Exiting the Intel Rapid Storage Technology enterprise SATA Option ROM utili...

Страница 6: ...he RAID controller driver 6 4 6 2 Management applications and utilities installation 6 6 6 3 Running the Support DVD 6 6 6 4 Installing the LAN driver 6 14 6 5 Installing the VGA driver 6 19 6 6 Installing the Intel C22x MEI NULL HECI driver 6 22 6 7 Installing the Intel I210 Gigabit Adapter driver 6 24 ASUS contact information A 1 ...

Страница 7: ... harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment to an outlet on a circuit different from that to which the rec...

Страница 8: ...efore operating the server carefully read all the manuals included with the server package Before using the server make sure all cables are correctly connected and the power cables are not damaged If any damage is detected contact your dealer as soon as possible To avoid short circuits keep paper clips screws and staples away from connectors slots sockets and circuitry Avoid dust humidity and temp...

Страница 9: ...r commitment to the highest standards for protecting our environment We believe in providing solutions for you to be able to responsibly recycle our products batteries other components as well as the packaging materials Please go to http csr asus com english Takeback htm for detailed recycling information in different regions Australia statement notice From 1 January 2012 updated warranties apply ...

Страница 10: ...that you have to perform when installing or removing system components 3 Chapter 3 Motherboard information This chapter includes the motherboard layout and brief descriptions of the jumpers and internal connectors 4 Chapter 4 BIOS information This chapter tells how to change system settings through the BIOS Setup menus and describes the BIOS parameters 5 Chapter 5 RAID configuration This chapter p...

Страница 11: ...ying to complete a task CAUTION Information to prevent damage to the components when trying to complete a task IMPORTANT Instructions that you MUST follow to complete a task NOTE Tips and additional information to help you complete a task Typography Bold text Indicates a menu or an item to select Italics Used to emphasize a word or a phrase Key Keys enclosed in the less than and greater than sign ...

Страница 12: ...xii ...

Страница 13: ...ASUS TS100 E8 PI4 This chapter describes the general features of the server including sections on front panel and rear panel specifications Chapter 1 Product introduction ...

Страница 14: ...ure below With the correct serial number of the product ASUS Technical Support team members can then offer a quicker and satisfying solution to your problems Model Name TS100 E8 PI4 Chassis ASUS T11 Pedestal Chassis Motherboard ASUS P9D X MR Server Board Component 1 x 300W Single Power Supply 1 x 120mm x 25mm System Fan 4 x SATA Cables 8 x HDD plastic rails 2 pcs per HDD 1 x Front I O Board FPB R9...

Страница 15: ...B Expansion Slots Total PCI PCI X PCI E Slots 6 Slot Type 1 x PCI E x16 Gen3 x16 link 1 x PCI E x8 Gen2 x4 link 3 x PCI 32 bit 33 MHz 1 x MIO slot Storage Intel C222 4 x SATA 3Gbps ports 2 x SATA 6Gbps ports Intel Rapid Storage Technology Enterprise RSTe supports software RAID 0 1 10 5 Windows HDD Bays I internal A or S hot swappable 4 x Internal 3 5 inch HDD Bays Networking LAN 2 x Intel I210AT c...

Страница 16: ... 5 6 6 2 6 3 64 bit Ubuntu 12 04 64 bit Anti virus Software Optional Anti Virus CD Pack Management Solution Software ASUS ASWM Enterprise Dimension HH x WW x DD 436 8 mm x 200 mm x 478 8 mm Net Weight Kg CPU DRAM HDD not inclu ded 15 Kg Power Supply 300W Bronze 80PLUS Single Power Supply Power Rating 100 127 220 240 Vac 6 3A 60 50Hz Class I Environment Operation temperature 10 C 40 C Non operation...

Страница 17: ...two USB ports are located on the front panel The drive bays power and reset buttons LED indicators CD DVD ROM drive and USB 2 0 ports are located on the front panel For future installation of 5 25 inch devices two drive bays are available Refer to section 1 7 1 Front panel LEDs for the LED descriptions Reset button HDD access LED Power LED USB 2 0 ports Optical drive Empty 5 25 inch bays Power but...

Страница 18: ...d rear I O ports expansion slots a chassis lock a vent for the system fan and power supply module 300W Bronze Single power supply Power connector Expansion slots USB 2 0 ports Serial port VGA port Gigabit LAN port 1 Chassis lock 120mm x 25mm system fan PS 2 keyboard mouse port Gigabit LAN port 2 USB 3 0 ports ...

Страница 19: ...s on the front or rear panel if you need to use a floppy disk or a optical disc WARNING HAZARDOUS MOVING PARTS KEEP FINGERS AND OTHER BODY PARTS AWAY Turn off the system power and detach the power supply before removing or replacing any system component 1 Power supply unit 2 120mm x 25mm system fan 3 ASUS P9D X MR Server Board 4 Expansion card locks 5 Optical drive 6 2 x 5 25 inch drive bays 7 Fro...

Страница 20: ...HDD Access LED OFF Blinking No activity Read write data into the HDD HDD Access LED Power LED 1 7 2 Rear panel LEDs SPEED LED ACT LINK LED SPEED LED ACT LINK LED ACT LINK LED SPEED LED Status Description Status Description OFF No link OFF 10 Mbps connection GREEN Linked ORANGE 100 Mbps connection BLINKING Data activity GREEN 1 Gbps connection ...

Страница 21: ...ASUS TS100 E8 PI4 This chapter lists the hardware setup procedures that you have to perform when installing or removing system components Chapter 2 Hardware setup ...

Страница 22: ...hat can cause injury such as the CPU fan rear fan and other sharp edged parts The images of the barebone server shown in this section are for reference purposes only and may not exactly match the model you purchase 2 Slide the side cover for about half an inch toward the rear until it is disengaged from the chassis 3 Carefully lift the side cover and set it aside 1 1 2 To remove the side cover 1 R...

Страница 23: ... 1 Match and insert the lower sliding edge of the side cover to the corresponding chassis edge 2 Position the side cover to the chassis 4 Drive in the two screws you removed earlier to secure the side cover 3 Slide the side cover toward the front panel until it snaps in place 4 4 3 1 ...

Страница 24: ... is on the socket and the socket contacts are not bent Contact your retailer immediately if the PnP cap is missing or if you see any damage to the PnP cap socket contacts motherboard components ASUS will shoulder the cost of repair only if the damage is shipment transit related Keep the cap after installing the motherboard ASUS will process Return Merchandise Authorization RMA requests only if the...

Страница 25: ... tab 3 Lift the load lever until the load plate is completely lifted Load plate 4 Position the CPU above the socket ensuring that the gold triangle mark is on the bottom left corner of the socket then fit the CPU notches to the socket s alignment keys The CPU fits in only one orientation DO NOT force the CPU into the socket to prevent bending the pins on the socket and damaging the CPU Gold triang...

Страница 26: ...from the CPU socket Retention tab Load lever 7 Apply some Thermal Interface Material to the exposed area of the CPU that the heatsink will be in contact with ensuring that it is evenly spread in a thin layer Some heatsinks come with pre applied Thermal Interface Material If so skip this step The Thermal Interface Material is toxic and inedible DO NOT eat it If it gets into your eyes or touches you...

Страница 27: ...ocket is incompatible with the LGA775 and LGA1366 sockets in size and dimension Orient the heatsink and fan assembly such that the CPU fan cable is closest to the CPU fan connector To install the CPU heatsink and fan 1 Place the heatsink on top of the installed CPU making sure that the four fasteners match the holes on the motherboard 2 Push down two fasteners at a time in a diagonal sequence to s...

Страница 28: ...g this connector 2 2 3 Uninstalling the CPU heatsink and fan To uninstall the CPU heatsink and fan 1 Disconnect the CPU fan cable from the connector on the motherboard 2 Rotate each fastener counterclockwise 3 Pull up two fasteners at a time in a diagonal sequence to disengage the heatsink and fan assembly from the motherboard A A B B A A B B 4 Carefully remove the heatsink and fan assembly from t...

Страница 29: ... DIMM sockets 2 3 2 Memory Configurations You may install 2 GB 4 GB 8GB Unbuffered with ECC DDR3 DIMMs into the DIMM sockets using the memory configurations in this section UDIMM DIMM Slot Per Channel DIMM Populated per Channel DIMM Type Speed Rank per DIMM 2 1 Unbuffered DDR3 ECC 1333 1600 Single Rank Dual Rank 2 2 Unbuffered DDR3 ECC 1333 1600 Single Rank Dual Rank Always install DIMMs with the ...

Страница 30: ... socket Unlocked retaining clip DIMM notch 2 1 DIMM slot key 1 Press the retaining clip outward to unlock the DIMM 2 Remove the DIMM from the socket 1 2 Removing a DIMM from a single clip DIMM socket To install two or more DIMMs refer to the user guide bundled in the motherboard package Refer to the user guide for qualified vendor lists of the memory modules Support the DIMM lightly with your fing...

Страница 31: ... panel cover To remove the front panel cover 1 Locate the three hooked tabs on the chassis side rail 2 Release the hooked tabs and take off the front panel cover 2 4 2 Reinstalling the front panel cover To reinstall the front panel cover 1 Hook the other side of the front panel cover to the chassis 2 Swing the front panel cover and snap it back into place ...

Страница 32: ...ew driver to bend and remove the metal cover to avoid physical injury Ensure to unplug the power cable before installing or removing any system components Failure to do so may cause damage to the motherboard and other system components The system comes with three 5 25 inch drive bays located on the upper front part of the chassis An optical drive that comes standard optional with the system packag...

Страница 33: ...ug from the power supply to the power connector on the back of the drive 9 Follow the instructions on the previous section to reinstall the front panel cover 4 Insert the drive into the bay 5 Slide the bay lock to the right until it clicks in place 6 Push the bay lock latch down to secure the drive in place 7 8 6 5 ...

Страница 34: ...all a Serial ATA hard disk drive 1 Attach the bundled plastic HDD rails and secure it with four 4 screws 2 Carefully insert the HDD with the plastic HDD rails assembly all the way into the drive bay 3 Connect the SATA cable to the HDD SATA connector 4 Connect a power plug from the power supply to the power connector on the back of the drive 2 3 4 ...

Страница 35: ...system components 2 7 1 Installing an expansion card To install an expansion card 1 Before installing the expansion card read the documentation that came with it and make the necessary hardware settings for the card 2 Lay the system on its side on a flat stable surface 4 Push the expansion card to the left 5 Remove the metal slot cover opposite the slot where you wish to install an expansion card ...

Страница 36: ...Hardware setup 2 16 7 Restore the expansion card lock to its original position A light click indicates that the card is locked in place Ensure that the total power consumption of your system does not exceed 300W ...

Страница 37: ...vers for the expansion card These IRQs are usually available for ISA or PCI devices Standard Interrupt assignments IRQ Priority Standard function 0 1 System Timer 1 2 Keyboard Controller 2 Programmable Interrupt 3 11 Communications Port COM2 4 12 Communications Port COM1 5 13 6 14 Floppy Disk Controller 7 15 8 3 System CMOS Real Time Clock 9 4 ACPI Mode when used 10 5 IRQ Holder for PCI Steering 1...

Страница 38: ...he system fan 1 Unplug the system fan cable from the REAR_FAN1 connector on the motherboard 3 Remove the system fan and then set it aside 2 Locate and remove four system fan screws at the rear panel Keep the screws for late use Hold the system fan with one hand while removing the system fan screws Follow the previous instructions in reverse if you want to reinstall the system fan ...

Страница 39: ...tailed information on the connectors Standard cables connected to the motherboard 1 24 pin ATX power connector from power supply to motherboard 2 8 pin ATX 12V power connector from power supply to motherboard 3 System fan connector from system fan to motherboard 4 SATA conectors system default from motherboard to SATA devices 5 USB connectors from motherboard to front I O board 6 System panel conn...

Страница 40: ...Chapter 2 Hardware setup 2 20 ...

Страница 41: ...ASUS TS100 E8 PI4 This chapter includes the motherboard layout and brief descriptions of the jumpers and internal connectors Chapter 3 Motherboard Info ...

Страница 42: ...Chapter 3 Motherboard information 3 2 3 1 Motherboard layout ...

Страница 43: ...2 Hard disk activity LED connector 4 pin HDLED1 3 8 3 USB 2 0 connector 10 1 pin USB78 10 1 pin USB1011 A Type USB9 3 8 4 Thermal sensor cable connectors 3 pin TR1 3 9 5 CPU front and rear fan connectors 4 pin FRNT_FAN1 REAR_FAN1 CPU_FAN1 FRNT_FAN2 FRNT_FAN3 3 9 6 Serial General Purpose Input Output connector 6 1 pin SGPIO1 3 10 7 Serial port connectors 10 1 pin COM2 3 10 8 Trusted Platform Module...

Страница 44: ...e computer and unplug the power cord 2 Move the jumper cap from pins 1 2 default to pins 2 3 Keep the cap on pins 2 3 for about 5 10 seconds then move the cap back to pins 1 2 3 Plug the power cord and turn ON the computer 4 Hold down the Del key during the boot process and enter BIOS setup to re enter data Except when clearing the RTC RAM never remove the cap on CLRTC jumper default position Remo...

Страница 45: ...to enable or disable the onboard VGA controller Set to pins 1 2 to activate the VGA feature 3 LAN controller setting 3 pin LAN_SW1 LAN_SW2 These jumpers allows you to enable or disable the onboard Intel I210AT Gigabit LAN controllers Set to pins 1 2 to activate the Gigabit LAN feature ...

Страница 46: ...become corrupted 4 Intel C222 SATA port S W RAID setting 3 pin RAID_SEL1 This jumper allows you to select the Serial ATA RAID configuration utility to use when you create disk arrays Place the jumper caps on pins 1 2 if you want to use the LSI Logic Embedded SATA RAID Setup Utility default otherwise place the jumper caps on pins 2 3 to use the Intel Rapid Storage Techonology IRST ...

Страница 47: ...ported by the Intel C222 chipset these connectors are for the Serial ATA signal cables for Serial ATA hard disk drives that allows up to 6Gb s or 3Gb s of data transfer rate If you installed Serial ATA hard disk drives you can create a RAID 0 RAID 1 RAID 10 or RAID 5 configuration The actual data transfer rate depends on the speed of Serial ATA hard disks installed ...

Страница 48: ...ard The read or write activities of any device connected to the SATA or SAS add on card causes the front panel LED to light up 3 USB 2 0 connector 10 1 pin USB78 10 1 pin USB1011 A Type USB9 These connectors are for USB 2 0 ports Connect the USB module cables to connectors USB78 These USB connectors comply with USB 2 0 specification that supports up to 480 Mbps connection speed ...

Страница 49: ...fan connectors 4 pin FRNT_FAN1 REAR_FAN1 CPU_FAN1 FRNT_FAN2 FRNT_FAN3 The fan connectors support cooling fans Connect the fan cables to the fan connectors on the motherboard ensuring that the black wire of each cable matches the ground pin of the connector DO NOT forget to connect the fan cables to the fan connectors Insufficient air flow inside the system may damage the motherboard components The...

Страница 50: ...Storage Technology Enterprise SGPIO interface that controls the LED pattern generation device information and general purpose data 7 Serial port connectors 10 1 pin COM2 These connectors are for the serial COM2 port Connect the serial port module cable to one of these connectors then install the module to a slot opening at the back of the system chassis ...

Страница 51: ...stem which can securely store keys digital certificates passwords and data A TPM system also helps enhance network security protects digital identities and ensures platform integrity 9 SATA DOM power connector 4 pin PWR3 This 4 pin connector is for 5V power of certain SATA DOM Disk on Module device when using an appropriate cable ...

Страница 52: ...ntil the connectors completely fit DO NOT forget to connect the 24 pin and the 8 pin power plugs otherwise the system will not boot up Use of a power supply unit PSU with a higher power output is recommended when configuring a system with more power consuming devices The system may become unstable or may not boot up if the power is inadequate This motherboard supports ATX2 0 PSU or later version E...

Страница 53: ...KER This 4 pin connector is for the chassis mounted system warning speaker The speaker allows you to hear system beeps and warnings 4 Hard disk drive activity LED 2 pin HDLED This 2 pin connector is for the HDD Activity LED Connect the HDD Activity LED cable to this connector The IDE LED lights up or flashes when data is read from or written to the HDD 5 Power button soft off button 2 pin PWRSW Th...

Страница 54: ...trusion detection feature for chassis with intrusion sensor or microswitch When you remove any chassis component the sensor triggers and sends a high level signal to these leads to record a chassis intrusion event The default setting is short CASEOPEN and GND pin by jumper cap to disable the function 4 Locator LED 2 pin AUX_LOCLED1 and 2 pin AUX_LOCLED2 These leads are for the Locator LED1 and LED...

Страница 55: ...ASUS TS100 E8 PI4 This chapter tells how to change the system settings through the BIOS Setup menus Detailed descriptions of the BIOS parameters are also provided Chapter 4 BIOS setup ...

Страница 56: ...atically recover the BIOS It resets the system when the BIOS recovery finished DO NOT shut down or reset the system while recovering the BIOS Doing so would cause system boot failure The recovered BIOS may not be the latest BIOS version for this motherboard Visit the ASUS website at www asus com to download the latest BIOS file Save a copy of the original motherboard BIOS file to a bootable USB fl...

Страница 57: ...Left Right Switch Enter Choose q Exit FS0 System Volume Information DIR P9D X Bios DIR Windows DIR P9D X Bios Current Platform Platform P9D X Version 0060 Build Date 12 03 2013 New Platform Platform P9D X Version 0077 Build Date 01 31 2013 The succeeding BIOS screens are for reference only The actual BIOS screen displays may not be the same as shown To update the BIOS using EzFlash Utility 1 Inser...

Страница 58: ...DATER utility BUPDATER exe from the ASUS support website at support asus com to the bootable USB flash disk drive you created earlier 3 Boot the system in DOS mode then at the prompt type BUPDATER i filename CAP where filename is the latest or the original BIOS file on the bootable USB flash disk drive then press Enter A BUPDATER i file name CAP 7 Reboot the system when the update process is done ...

Страница 59: ... the DOS prompt after the BIOS update process is completed 4 Reboot the system from the hard disk drive The BIOS update is finished Please restart your system C ASUSTek BIOS Update for DOS V1 06 09 08 04 Current ROM Update ROM Note Writing BIOS FLASH TYPE MXIC 25L1605A PATH BOARD P9D X MR VER 0201 DATE 12 01 2013 BOARD P9D X MR VER 0202 DATE 12 09 2013 WARNING Do not turn off power during flash BI...

Страница 60: ...to run this program Press Del during the Power On Self Test POST to enter the Setup utility otherwise POST continues with its test routines If you wish to enter Setup after POST restart the system by pressing Ctrl Alt Del or by pressing the reset button on the system chassis You can also restart by turning the system off then back on Do this last option only if the first two failed The Setup progr...

Страница 61: ...nu bar press the right or left arrow key on the keyboard until the desired item is highlighted 4 2 1 BIOS menu screen Version 2 15 1236 Copyright C 2013 American Megatrends Inc Aptio Setup Utility Copyright C 2013 American Megatrends Inc Main Advanced Event Logs Boot Monitor Security Tool Exit Set the Date Use Tab to switch between Data elements Select Screen Select Item Enter Select Item Change O...

Страница 62: ...en are the navigation keys for the BIOS setup program Use the navigation keys to select items in the menu and change the settings 4 2 6 General help At the top right corner of the menu screen is a brief description of the selected item 4 2 7 Configuration fields These fields show the values for the menu items If an item is user configurable you can change the value of the field opposite the item Y...

Страница 63: ...day numeric value yyyy year numeric value 4 3 2 System Time Allows you to set the system time to hh mm ss Where hh hour numeric value mm minutes numeric value ss seconds numeric value Aptio Setup Utility Copyright C 2013 American Megatrends Inc Main Advanced Event Logs Boot Monitor Security Tool Exit Set the Date Use Tab to switch between Data elements BIOS InformationBIOS Vendor American Megatren...

Страница 64: ...A Configuration USB Configuration NCT6779D Super IO Configuration Intel Server Platforms Services Onboard LAN Configuration MIO Card Configuration Serial Port Console Redirection APM Network Stack Intel RC Drivers Version Details Aptio Setup Utility Copyright C 2013 American Megatrends Inc Main Advanced Event Logs Boot Monitor Security Tool Exit PCI PCI X and PCI Express Settings CPU Configuration...

Страница 65: ...Package C state undemotion Disabled C state Pre Wake Enabled CFG lock Enabled Package C State limit AUTO LakeTiny Feature Disabled Intel TXT LT Support Disabled Select Screen Select Item Enter Select Item Change Opt F1 General Help F2 Previous Values F5 Optimized Defaults F10 Save Exit ESC Exit Navigate to the second page of the screen to see the rest of items in this menu by pressing the Up or Do...

Страница 66: ...d Disabled Adjacent Cache Line Prefetch Enabled Allows you to enable or disable the Mid Level Cache L2 prefetching of adjacent cache lines Configuration options Enabled Disabled CPU AES Enabled Allows you to enable or disable the CPU Advance Encryption Standard instructions Configuration options Disabled Enabled Boot performance mode Turbo Performance This item allows you to select the performance...

Страница 67: ... Disabled Enabled C1 state auto undemotion Enabled Allows you to enable or disable the Un demotion from C1 Configuration options Disabled Enabled C3 state auto undemotion Enabled Allows you to enable or disable the Un demotion from C1 Configuration options Disabled Enabled Package C state demotion Disabled Allows you to enable the Package C state undemotion Configuration options Disabled Enabled C...

Страница 68: ... Mode Auto EHCI1 Enabled EHCI2 Enabled USB Ports Per Port Disable Control Disabled XHCI Mode Auto Allows you to set the mode of operation of the xHCI controller Configuration options Auto Enabled Disabled EHCI1 EHCI2 Enabled Allows you to control the USB EHCI USB 2 0 functions One EHCI controller must always be enabled Configuration options Disabled Enabled USB Ports Per Port Disable Control Disab...

Страница 69: ... Inc Advanced SATA Controller s Enabled SATA Mode Selection AHCI S M A R T Status Check Enabled Serial ATA Port 0 HardDisk 250 0GB Software Preserve SUPPORTED Port 0 Enabled Hot Plug Enabled SATA Device Type Hard Disk Drive Spin Up Device Disabled Serial ATA Port 1 HardDisk 250 0GB Software Preserve SUPPORTED Port 1 Enabled Hot Plug Enabled SATA Device Type Hard Disk Driver Spin Up Device Disabled...

Страница 70: ... SUPPORTED Determines how SATA controller s operate 4 4 4 System Agent SA Configuration This allows you to change System Agent parameters VT d Enabled This allows you enable or disable the VT d function on MCH Configuration options Enabled Disabled Aptio Setup Utility Copyright C 2013 American Megatrends Inc Advanced System Agent Bridge Name Haswell System Agent RC Version 1 0 0 0 VT d Capability ...

Страница 71: ...harge tRASmin 24 Memory Frequency Limiter Auto Memory Scrambler Enabled Memory Remap Enabled GDXC Support Disabled Maximum Memory Frequency Selections in MHz Memory Frequency Limiter Auto This allows you to set the memory frequency in MHz Configuration options Auto 1333 1600 Memory Scrambler Enabled This allows you to enable or disable the Memory Scrambler support Configuration options Enabled Dis...

Страница 72: ...oad RT32 Image Enabled Allows you to enable or disable the RT32 Image Loading Configuration Options Disabled Enabled PCI Express Settings Allows you to change the settings of the PCI Express Devices Aptio Setup Utility Copyright C 2013 American Megatrends Inc Advanced Set the ASPM Level Force L0s Force all links to L0s State AUTO BIOS auto configure DISABLE Disables ASM PCI Express Device Register...

Страница 73: ...4 5 Enabled Allows you to enable or disable the PCIE slots Configuration Options Disabled Enabled Aptio Setup Utility Copyright C 2013 American Megatrends Inc Advanced PCIE Slot Configuration PCIE4 Not Present PCIE4 Option Rom Enabled PCIE5 Not Present PCIE5 Option Rom Enabled Enabled Disabled PCIE4 Option Rom ...

Страница 74: ...disable the support for legacy USB devices Setting to Auto allows the system to detect the presence of USB devices at startup If detected the USB controller legacy mode is enabled If no USB device is detected the legacy USB support is disabled Configuration options Disabled Enabled Auto USB3 0 Support Enabled Enables or disables the USB3 0 XHCI controller support Configuration options Disabled Ena...

Страница 75: ...lue Configuration options 10 sec 20 sec 30 sec 40 sec Device power up delay Auto This allows you to set the maximum time the device will take before it properly reports itself to the Host Controller Configuration options Auto Manual Enable Hibernation Enabled Allows you to enable or disable the Hibernation feature OS S4 sleep state Configuration options Disabled Enabled ACPI Sleep State Both S1 an...

Страница 76: ...OM1 and the Serial Port 2 COM2 Serial Port Enabled Allows you to enable or disable the serial port COM 1 2 Configuration options Enabled Disabled Change Settings Auto This item only appears when you set the Serial Port to Enabled This item allows you to select the serial port base address Configuration options Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 10 11 12 IO 2F8h IRQ 3 4 5 6 7 10 11 12 IO 3E8h...

Страница 77: ...ode Configuration options STD Printer mode SPP Mode EPP 1 9 and SPP Mode EPP 1 7 and SPP Mode ECP Mode ECP and EPP 1 9 Mode ECP and EPP 1 7 Mode 4 4 11 IntelServer Platform Services This item displays the information of the Intel Server Platform Services configured in the system Aptio Setup Utility Copyright C 2013 American Megatrends Inc Advanced Intel Sever Platform Services Configuration ME BIO...

Страница 78: ...0 LAN Disable Enable Onboard LAN Configuration INTEL I210 LAN1 MAC 00 E0 18 10 18 E8 INTEL I210 LAN2 MAC 00 E0 18 10 18 E9 INTEL I210 LAN1 Enable Enabled INTEL I210 LAN1 OpROM PXE INTEL I210 LAN2 Enable Enabled INTEL I210 LAN2 OpROM PXE 4 4 13 MIO Card Configuration This item allows you to set MIO Card configuration settings MIO Card Type ALC 892 Allows you to select the MIO card type Configuratio...

Страница 79: ...e user is using will exchange data Both computers should have the same or compatible settings Terminal Type VT UTF8 Allows you to set the terminal type VT100 ASCII char set VT100 Extends VT100 to support color function keys among others VT UTF8 Uses UTF8 encoding to map Unicode chars onto 1 or more bytes ANSI Extended ASCII char set Bits per second 57600 Selects serial port transmission speed The ...

Страница 80: ... to select the FunctionKey and Keypad on Putty Configuration options VT100 LINUX XTERMR6 SCO ESCN VT400 Redirection After BIOS POST Bootloader This setting allows you to specify if Bootloader is selected than Legacy console redirection Configuration options Always Enable Bootloader Serial Port for Out of Band Management Windows Emergency Management Services EMS Settings The following items only ap...

Страница 81: ...When set to Enabled the items RTC Alarm Date Days and Hour Minute Second becomes user configurable where you can set values EUP Ready Disabled This item allows you to switch off some power at S5 to get the system ready for EuP requirement Configuration options Enabled Disabled 4 4 15 Runtime Error Logging Support Aptio Setup Utility Copyright C 2013 American Megatrends Inc Advanced Runtime Error L...

Страница 82: ...abled Enables or disables the Ipv6 PXE Boot Support If disabled Ipv6 PXE boot option will not be created Configuration options Disable Enable 4 4 18 Intel RC Drivers Version Detail This item displays the Version String for the Intel RC Drivers 4 4 17 Network Stack Aptio Setup Utility Copyright C 2013 American Megatrends Inc Advanced Network stack Disable Enable Disable the network stack Pxe and UE...

Страница 83: ...o select the options for reaction when the event logs are full Configuration options Do Nothing Erase Immediately Change Smbios Event Log Settings Change this to enable or disable all features of Smbios Event Logging during boot Enabling Disabling Options Smbios Event Log Enabled Erasing Settings Erase Event Log No When Log is Full Do Nothing NOTE All values changed here do not take effect until c...

Страница 84: ... the GA20 can be disabled using BIOS services When set to Always disabling of GA20 is not allowed Configuration options Upon Request Always Option ROM Messages Force BIOS Allows you to set the display mode for Option ROM Configuration options Force BIOS Keep Current Number of seconds to wait for setup activation key 65535 0xFFFF means indefinite waiting Boot Configuration Setup Prompt Timeout 1 Bo...

Страница 85: ... is pressed by the user Normal Seek remote boot image once then stop Boot Option Priorities These items specify the boot device priority sequence from the available devices The number of device items that appears on the screen depends on the number of devices installed in the system Network Device BBS Priorities Hard Drive BBS Priorities This allows you to set the order of the legacy devices in th...

Страница 86: ...the system can boot to Configuration options UEFI and Legacy Legacy only UEFI only Launch PXE OpROM policy Legacy only This option allows you to control the execution of UEFI and Legacy PXE OpROM Configuration options Do not launch UEFI only Legacy only Legacy first UEFI first Launch Storage OpROM policy Legacy only This option allows you to control the execution of UEFI and Legacy Storage OpROM C...

Страница 87: ...BAT The onboard hardware monitor automatically detects the voltage output through the onboard voltage regulators Fan Speed Control Generic Mode Allows you to configure the ASUS Smart Fan feature that smartly adjusts the fan speeds for more efficient system operation Configuration options Low Speed Mode Generic Mode High Speed Mode Full Speed Mode Whisper Generic High Speed Full Speed Aptio Setup U...

Страница 88: ...ss Enter 3 Confirm the password when prompted To change an administrator password 1 Select the Administrator Password item and press Enter 2 From the Enter Current Password box key in the current password then press Enter 3 From the Create New Password box key in a new password then press Enter 4 Confirm the password when prompted To clear the administrator password follow the same steps as in cha...

Страница 89: ... from the Warning message window then press Enter Secure Boot Menu This item allows you to customize the Secure Boot settings Secure Boot Control Enabled This item allows you to enable or disable the Secure Boot flow control Configuration options Disabled Enabled Secure Boot Mode Standard This item allows you to select the mode of the Secure boot to change Execution policy and Secure Boot Key mana...

Страница 90: ...n Security Violation Install Factory default Secure Boot Keys when System is in Setup Mode Aptio Setup Utility Copyright C 2013 American Megatrends Inc Security Factory Default Key Provisioning Disabled Install All Factory Default Keys Platform Key PK NOT INSTALLED Set new PK Delete PK Key Exchange Key Database KEK NOT INSTALLED Set new KEK Delete KEK Append Var to KEK Authorized Signature Databas...

Страница 91: ... appears Select Yes to save changes and exit Start EzFlash utility Allows you to run the Start EzFlash utility For more information see section 4 1 2 ASUS EzFlash utility 4 9 Tool menu The Tool menu items allow you to configure options for special functions Select an item then press Enter to display the submenu Press ENTER to run the utility to select and update BIOS Start EzFlash Aptio Setup Util...

Страница 92: ...lts This option allows you restore or load the default values for all the setup options When you select this option or if you press ENTER a confirmation window appears Select Yes to apply the default values or press Esc to exit Launch EFI Shell from filesystem device This option allows you to launch the EFI Shell application shellx64 efi from one of the available filesystem devices Select Yes to p...

Страница 93: ...ASUS TS100 E8 PI4 This chapter provides instructions for setting up creating and configuring RAID sets using the available utilities Chapter 5 RAID configuration ...

Страница 94: ...reases fault tolerance to the entire system Use two new drives or use an existing drive and a new drive for this setup The new drive must be of the same size or larger than the existing drive RAID 10 is data striping and data mirroring combined without parity redundancy data having to be calculated and written With the RAID 10 configuration you get all the benefits of both RAID 0 and RAID 1 config...

Страница 95: ...ou can create a RAID set using the utilities embedded in each RAID controller For example use the Intel Rapid Storage Technology enterprise SATA Option ROM Utility if you installed Serial ATA hard disk drives on the Serial ATA connectors supported by the Intel C222 chipset 5 1 2 Installing hard disk drives The motherboard supports Serial ATA for RAID set configuration For optimal performance insta...

Страница 96: ... 2 During POST press Ctrl I to display the utility main menu Before you proceed ensure that you have installed the Serial ATA hard disk drives and have set the correct SATA mode in the BIOS setup You can refer to sections 5 1 2 Installing hard disk drives and 5 1 3 Setting the RAID mode in BIOS for more information ESC Exit ENTER Select Menu Select Intel R Rapid Storage Technology enterprise SATA ...

Страница 97: ...ter when you are done ESC Previous Menu ENTER Select Change Intel R Rapid Storage Technology enterprise SATA Option ROM 3 6 0 1023 Copyright C 2003 12 Intel Corporation All Rights Reserved CREATE VOLUME MENU HELP Name RAID Level Disks Strip Size Capacity Syne Create Volume Enter a unique volume name that has no special characters and is 16 characters or less Volume0 RAID0 Strips Select Disks 128KB...

Страница 98: ...gher stripe size for multimedia computer systems used mainly for audio and video editing 7 In the Capacity field item key in the RAID volume capacity that you want to use and press Enter The default value field indicates the maximum allowed capacity 8 Press Enter to start creating the RAID volume 9 From the following warning message press Y to create the RAID volume and return to the main menu or ...

Страница 99: ... to the utility main menu or press N to return to the DELETE VOLUME menu ESC Previous Menu Select Intel R Rapid Storage Technology enterprise SATA Option ROM 3 6 0 1023 Copyright C 2003 12 Intel Corporation All Rights Reserved DELETE VOLUME MENU HELP Deleting a volume will reset the disks to non RAID WARNING ALL DISK DATA WILL BE DELETED This does not apply to Recovery volumes DEL Delete Volume Na...

Страница 100: ...ace A small triangle before the Port number marks the selected drive Press Enter when you are done 3 Press Y in the confirmation window to reset the drive s or press N to return to the utility main menu Port Drive Model Serial Size Status 0 ST3300656SS HWAS0000991753TR 279 3GB Member Disk 1 ST3300656SS 37VN00009846RAJ1 279 3GB Member Disk Select the disks that should be reset Resetting RAID disk w...

Страница 101: ...A Hard Disk available the utility will prompt you to rebuild the RAID Press the up down arrow keys to select the destination disk then Press Enter to start the rebuilding process or press ESC to exit 5 2 4 Exiting the Intel Rapid Storage Technology enterprise SATA Option ROM utility To exit the utility 1 From the utility main menu select 4 Exit then press Enter 2 Press Y to exit or press N to retu...

Страница 102: ...ded during POST You may replace the disk drive and rebuild the RAID array To rebuild the RAID with a new hard disk 1 Remove the failed SATA hard disk and install a new SATA hard disk of the same specification into the same SATA Port Select a destination disk with the same size as the original hard disk 2 Reboot the system then follow the steps in section Rebuilding the RAID with other non RAID dis...

Страница 103: ...ay in the BIOS Set at least one of the arrays bootable to boot from the hard disk 1 Reboot the system and press Del to enter the BIOS setup utility during POST 2 Go to the Boot menu and select the boot option priority 3 Use up down arrow keys to select the boot priority and press Enter See the Boot menu section of Chapter 4 for more details 4 From the Exit menu select Save Changes Exit then press ...

Страница 104: ... Turn on the system to windows desktop 2 Click the Intel Rapid Storage Technology enterprise icon to display the main menu Your storage system is configured for data protection increased performance and optimal data storage capacity You can create additional volumes to further optimize your storage system To enter the Intel Rapid Storage Technology enterprise utility under Windows operating system...

Страница 105: ...me type and click Next 2 Key in a name for the RAID set then select the array disks 3 Select the Volume Size tab then drag the bar to set the volume size 4 Click Next If you do not want to keep the data on one of the selected disks select NO when prompted If you want to Enable volume write back cache or Initialize volume click Advanced ...

Страница 106: ... and size of the disks You can continue using other applications during this time 6 Wait until the process is completed then click OK when prompted You still need to partition your new volume using Windows Disk Management before adding any data The created RAID set is displayed in the Volumes list If you wish to change the settings go to Volume Properties ...

Страница 107: ...ize for server systems and a higher stripe size for multimedia computer systems used mainly for audio and video editing 3 You can also change the Name Select the new volume type and Select additional disks to include in the new volume if needed 4 Select the Data stripe size for the RAID array for RAID 0 10 and 5 only and click OK The available stripe size values range from 4 KB to 128 KB The follo...

Страница 108: ...proceed ensure that you back up all your important data from your hard drives To delete a volume 1 From the Volumes field in the utility main menu select the volume that you want to delete 2 From the Volume Properties field select Delete volume 3 Click Yes to delete the volume and return to the utility main menu or click No to return to the main menu ...

Страница 109: ...ences Allow you to set to show the notification area icon and show system information warning or errors here E Mail Preferences Allow you to set to sent e mail of the following events Storage system information Storage system warnings Storage system errors ...

Страница 110: ...5 18 Chapter 5 RAID configuration ...

Страница 111: ...ASUS TS100 E8 PI4 This chapter provides instructions for installing the necessary drivers for different system components Chapter 6 Driver installation ...

Страница 112: ...t You can create a RAID driver disk in DOS using the Makedisk application in the support DVD To create a RAID driver disk in DOS environment 1 Place the motherboard support DVD in the optical drive 2 Restart your computer 3 Enter the BIOS Setup 4 Select the optical drive as the first boot priority to boot from the support DVD Save your changes 5 Exit the BIOS Setup and restart your computer The fo...

Страница 113: ...ette into the disk drive and press Enter to write the image to the disk 11 Press any key to continue when prompted The Create Driver Diskette Menu appears after the creation of the diskette is finished To create a RAID driver disk in Windows environment 1 Start Windows 2 Place the motherboard support DVD into the optical drive 3 Go to the Make disk menu then select the type of RAID driver disk you...

Страница 114: ...lation To install the RAID controller driver when installing Windows Server 2008 OS 1 Boot the computer using the Windows Server 2008 OS installation disc Follow the screen instructions to start installing Windows Server 2008 2 When prompted to choose a type of installation click Custom advanced 3 Click Load Driver ...

Страница 115: ...board Support DVD into the optical drive Click Browse to continue 5 Locate the driver in the corresponding folder of the Support DVD and then click OK to continue 6 Select the RAID controller driver you need from the list and click Next 7 When the system finishes loading the RAID driver replace the motherboard Support DVD with the Windows Server installation disc Select the drive to install Window...

Страница 116: ...VD 1 The contents of the support DVD are subject to change at any time without notice Visit the ASUS website www asus com for the latest updates on software and utilities 2 The support DVD is supported on Windows Server 2008 R2 and Windows Server 2012 The support DVD that is bundled with your motherboard contains drivers management applications and utilities that you can install to maximize the fe...

Страница 117: ...le device drivers if the system detects installed devices Install the necessary drivers to activate the devices 6 3 2 Utilities menu tab The Utilities menu displays the software applications and utilities that the motherboard supports 6 3 1 Drivers menu tab ...

Страница 118: ...driver disks 6 3 3 MakeDisk menu tab Press the arrow down button in the lower part of the menu to view more items 6 3 4 Manual menu The Manual menu provides the link to the Broadcom NetXtreme II Network Adapter user guide You need an internet browser installed in your OS to view the User Guide ...

Страница 119: ...l the Intel chipset device software on the system You need to manually install the Intel chipset device software on a Windows Operating System To install the Intel chipset device software on Windows Server 2008 R2 1 Restart the computer 2 Log in with Administrator privileges 3 Insert the Motherboard Support DVD to the optical drive The support DVD automatically displays the Drivers menu if Autorun...

Страница 120: ... Driver installation 5 From the Intel Chipset Device Software click Next to start the installation 6 In the License Agreement window click Yes to continue 7 Read the Readme File information and click Next to continue ...

Страница 121: ...omputer select Yes I want to restart this computer now then click Finish to complete the installation 8 Click Install in the Windows Security window The Windows Security window may appear more than once and you may have to click Install several times to continue with the installation ...

Страница 122: ...Insert the Motherboard Support DVD to the optical drive The support DVD automatically displays the Drivers menu if Autorun is enabled in your computer If Autorun is NOT enabled in your computer browse the contents of the support DVD to locate the file ASSETUP EXE from the BIN folder Double click the ASSETUP EXE to run the support DVD 5 From the Intel Chipset Device Software click Next 6 In the Lic...

Страница 123: ...ASUS TS100 E8 PI4 6 13 7 Read the Readme File information and click Next to continue 8 When done click Finish to complete the installation ...

Страница 124: ...g system To install the LAN controller device on Windows Server 2008 R2 1 Restart the computer 2 Log in with Administrator privileges 3 Insert the Motherboard Support DVD to the optical drive The support DVD automatically displays the Drivers menu if Autorun is enabled in your computer If Autorun is NOT enabled in your computer browse the contents of the support DVD to locate the file ASSETUP EXE ...

Страница 125: ... for Intel R Network Connections 7 From the License Agreement window select I accept the terms in the license agreement then click Next 8 Select the drivers you want to install in the Setup Options window and click Next 9 From the Ready to Install the Program window click Install ...

Страница 126: ...ceed with the installation 4 Click Intel Network Connections Software on the Drivers menu to start the installation To install the LAN controller device on Windows Server 2012 1 Restart the computer 2 Log in with Administrator privileges 3 Insert the Motherboard Support DVD to the optical drive The support DVD automatically displays the Drivers menu if Autorun is enabled in your computer If Autoru...

Страница 127: ... Network Connections window click Install Drivers and Software 6 Click Next in the Welcome to the InstallShield Wizard for Intel R Network Connections window 7 Select the drivers you want to install in the Setup Options window and click Next ...

Страница 128: ...6 18 Chapter 6 Driver installation 8 Click Install to continue 9 When done click Finish to complete the installation ...

Страница 129: ...d Support DVD to the optical drive The support DVD automatically displays the Drivers menu if Autorun is enabled in your computer 4 From the Main Menu click ASPEED AST2300 AST1300 Display Driver on the Drivers tab to start the installation If Autorun is NOT enabled in your computer browse the contents of the support DVD to locate the file ASSETUP EXE from the BIN folder Double click the ASSETUP EX...

Страница 130: ...hapter 6 Driver installation 6 Key in a username and organization then click Next 7 Select Complete in the Setup Type window then click Next 8 Click Install to begin the installation 9 When done click Finish ...

Страница 131: ...ically displays the Drivers menu if Autorun is enabled in your computer 4 Click ASPEED AST2300 AST1300 Display Driver on the Drivers menu to start the installation If Autorun is NOT enabled in your computer browse the contents of the support DVD to locate the file ASSETUP EXE from the BIN folder Double click the ASSETUP EXE to run the support DVD 5 Click OK in the Driver Information window Wait fo...

Страница 132: ...trator privileges 3 Insert the motherboard system support DVD to the optical drive If Autorun is NOT enabled in your computer browse the contents of the support DVD to locate the file ASSETUP EXE from the BIN folder Double click the ASSETUP EXE to run the support DVD 4 Click Intel C22x MEI NULL HECI on the Drivers menu of the main screen to start the installation 5 From the Welcome to the Setup Pr...

Страница 133: ...ASUS TS100 E8 PI4 6 23 7 Click NEXT when the installation of driver is complete 8 Click Finish to complete the installation ...

Страница 134: ...ter 2 Log on with Administrator privileges 3 Insert the motherboard system support DVD to the optical drive If Autorun is NOT enabled in your computer browse the contents of the support DVD to locate the file ASSETUP EXE from the BIN folder Double click the ASSETUP EXE to run the support DVD 4 Click Intel I210 Gigabit Adapter Driver in the Drivers menu of the main screen to start the installation ...

Страница 135: ...E8 PI4 6 25 8 Click Install in the Ready to Modify the Program window to begin with the loading of the selected options 7 Select the options you want to install then click Next to continue 9 When done click Finish ...

Страница 136: ...n is NOT enabled in your computer browse the contents of the support DVD to locate the file ASSETUP EXE from the BIN folder Double click the ASSETUP EXE to run the support DVD 4 Click Intel I210 Gigabit Adapter Driver in the Drivers menu of the main screen to start the installation 5 Click Next to continue 6 From the Program Maintenance window select Modify then click Next 7 Select the options you...

Страница 137: ...ASUS TS100 E8 PI4 6 27 8 In the Ready to Modify the Program window click Install to load the options you selected 9 When done click Finish ...

Страница 138: ...6 28 Chapter 6 Driver installation ...

Страница 139: ...wan Address 15 Li Te Road Peitou Taipei Taiwan 11259 Telephone 886 2 2894 3447 Fax 886 2 2890 7798 E mail info asus com tw Web site http www asus com tw Technical Support Telephone 886 2 2894 3447 0800 093 456 Online Support http support asus com techserv techserv aspx ASUSTeK COMPUTER INC China Address No 508 Chundong Road Xinzhuang Industrial Zone Minhang District Shanghai China Telephone 86 21 ...

Страница 140: ... Str 21 23 D 40880 Ratingen Germany Fax 49 2102 959911 Web site http www asus de Online contact http www asus de sales Technical Support Telephone 49 1805 010923 Support Fax 49 2102 959911 Online support http support asus com techserv techserv aspx ASUS Czech Service s r o Europe Address Na Rovince 887 720 00 Ostrava Hrabová Czech Republic Telephone 420 596766888 Web site http www asus cz Technica...

Страница 141: ...t asus com techserv techserv aspx ASUS Polska Sp z o o Poland Address Ul Postępu 6 02 676 Warszawa Poland Web site http pl asus com Technical Support Telephone 48 225718033 Online Support http support asus com techserv techserv aspx ASK Service Russia and CIS Address г Москва ул Орджоникидзе д 10 Россия Telephone 495 640 32 75 Web site http ru asus com Technical Support Telephone 008 800 100 ASUS ...

Страница 142: ...A 4 Appendix ...

Отзывы: