5-16
Chapter 5: BIOS Setup
Parity [None]
A parity bit can be sent with the data bits to detect some transmission errors. [Mark]
and [Space] parity do not allow for error detection.
[None]
None
[Even]
parity bit is 0 if the num of 1’s in the data bits is even
[Odd]
parity bit is 0 if num of 1’s in the data bits is odd
[Mark]
parity bit is always 1
[Space]
parity bit is always 0
Stop Bits [1]
Stop bits indicate the end of a serial data packet. (A start bit indicates the beginning.)
The standard setting is 1 stop bit. Communication with slow devices may require more
than 1 stop bit.
Configuration options: [1] [2]
Flow Control [Hardware RTS/CTS]
Flow control can prevent data loss from buffer overflow. When sending data, if the
receiving buffers are full, a “stop” signal can be sent to stop the data flow. Once the
buffers are empty, a “start” signal can be sent to re-start the flow. Hardware flow
control uses two wires to send start/stop signals.
Configuration options: [None] [Hardware RTS/CTS]
VT -UTF8 Combo Key Support [Enabled]
This allows you to enable the VT -UTF8 Combination Key Support for ANSI/VT100
terminals.
Configuration options: [Disabled] [Enabled]
Recorder Mode [Disabled]
With this mode enabled only text will be sent. This is to capture Terminal data.
Configuration options: [Disabled] [Enabled]
Legacy OS Redirection Resolution [80x24]
This allows you to set the number of rows and columns supported on the Legacy OS.
Configuration options: [80x24] [80x25]
Putty Keypad [VT100]
This allows you to select the FunctionKey and Keypad on Putty.
Configuration options: [VT100] [LINUX] [XTERMR6] [SCO] [ESCN] [VT400]
Redirection After BIOS POST [Always Enable]
This setting allows you to specify if Bootloader is selected than Legacy console
redirection.
Configuration options: [Always Enable] [Bootloader]
Legacy Console Redirection Settings
Legacy Console Redirection Port [COM1]
Allows you to select a COM port to display redirection of Legacy OS and Legacy OPROM
Messages.
Configuration options: [COM1] [COM2]
Содержание RS720A-E9-RS24-E
Страница 1: ...2U Rackmount Server User Guide RS720A E9 RS24 E ...
Страница 10: ...x ...
Страница 24: ...Chapter 1 Product Introduction 1 14 ...
Страница 63: ...3 5 ASUS RS720A E9 RS24 E 3 3 Rail kit dimensions 589mm 43 6mm 900mm 43 6mm ...
Страница 64: ...Chapter 3 Installation Options 3 6 ...
Страница 66: ...Chapter 4 Motherboard Information 4 2 4 1 Motherboard layout ...
Страница 88: ...4 5 Motherboard layout revised motherboard ...
Страница 94: ...8 IPMI SW setting 3 pin IPMI_SW1 This jumper allows you to select which protocol in the GPU sensor to function ...
Страница 97: ...5 BMC LED BMCLED1 The BMC LED lights up to indicate that the on board BMC is functional ...
Страница 110: ...Chapter 4 Motherboard Information 4 46 ...
Страница 153: ...ASUS RS720A E9 RS24 E 6 9 6 Click Finish to complete the installation 5 Click Install to start the installation process ...
Страница 154: ...6 10 Chapter 6 Driver Installation ...
Страница 155: ...Appendix Appendix This appendix includes additional information that you may refer to when configuring the motherboard ...
Страница 156: ...A 2 Appendix KNPP D32 block diagram ...
Страница 162: ...A 8 Appendix ...