3-28
Chapter 3: BIOS setup
Chapter 3
CPU Fan Min. Duty Cycle(%) [20]
Use the <+> and <-> keys to adjust the minimum CPU fan duty cycle. The values range from 0%
to 100%. When the CPU temperature is under 40ºC, the CPU fan will operate at the minimum
duty cycle.
Chassis1/2 Q-Fan Control [Enabled]
[Disabled]
Disables the Chassis1/2 Q-Fan control feature.
[Enabled]
Enables the Chassis1/2 Q-Fan control feature.
Chassis1/2 Fan Speed Low Limit [600 RPM]
This item appears only when you enable the
Chassis1/2 Q-Fan Control
feature and allows
you to disable or set the chassis1/2 fan warning speed.
Configuration options: [Ignore] [200 RPM] [300 RPM] [400 RPM] [500 RPM] [600 RPM]
Chassis1/2 Fan Profile [Standard]
This item appears only when you enable the
Chassis1/2 Q-Fan Control
feature and
allows you to set the appropriate performance level of the chassis1/2 fan.
[Standard] Sets to [Standard] to make the chassis fan automatically adjust depending
on the chassis temperature.
[Silent]
Sets to [Silent] to minimize the fan speed for quiet chassis fan operation.
[Turbo]
Sets to [Turbo] to achieve maximum chassis fan speed.
[Manual] Sets to [Manual] to assign detailed fan speed control parameters.
The following four items appear only when you set
Chassis1/2 Fan Profile
to [Manual].
Chassis1/2 Upper Temperature [70]
Use the <+> and <-> keys to adjust the upper limit of the chassis temperature. The values range
from 40ºC to 90ºC.
Chassis1/2 Fan Max. Duty Cycle(%) [100]
Use the <+> and <-> keys to adjust the maximum chassis fan duty cycle. The values range
from 20% to 100%. When the chassis temperature reaches the upper limit, the chassis fan will
operate at the maximum duty cycle.
Chassis1/2 Lower Temperature [40]
Displays the lower limit of the chassis temperature.
Chasis1/2 Fan Min. Duty Cycle(%) [60]
Use the <+> and <-> keys to adjust the minimum chassis fan duty cycle. The values range from
0% to 100%. When the chassis temperature is under 40ºC, the chassis fan will operate at the
minimum duty cycle.
Anti Surge Support [Enabled]
This item allows you to enable or disable the Anti Surge function.
Configuration options: [Disabled] [Enabled]
Содержание P8Z77-V LE V3
Страница 1: ...Motherboard P8Z77 V LE ...
Страница 49: ...ASUS P8Z77 V LE 2 29 Chapter 2 A B C 4 5 3 ...
Страница 51: ...ASUS P8Z77 V LE 2 31 Chapter 2 To uninstall the CPU heatsink and fan assembly 2 A B B A 1 ...
Страница 52: ...2 32 Chapter 2 Hardware information Chapter 2 1 2 3 To remove a DIMM 2 3 4 DIMM installation B A A ...
Страница 55: ...ASUS P8Z77 V LE 2 35 Chapter 2 2 3 6 ATX Power connection 1 2 OR OR ...
Страница 56: ...2 36 Chapter 2 Hardware information Chapter 2 2 3 7 SATA device connection 2 OR 1 ...
Страница 64: ...2 44 Chapter 2 Hardware information Chapter 2 ...
Страница 156: ...A 6 Appendices Appendices ...