background image

Max/Min Button

When taking a measurement, press this button once to enter “Max Mode”. In this mode, the 
multimeter will capture the highest reading it records. Press this button again to enter “Min Mode” 
which will capture the lowest reading it records. 

Press and hold this button to exit the Max/Min Modes.

Range Button

AC/DC Voltage, AC Current, and Resistance can all be measured in both Auto and Manual 
ranging. The multimeter will come set to Auto, but if you desire to select the range manually, 
press the Range Button repeatedly to find the desired range. Beware of selecting a range too 
low, as it will Overload the device and the multimeter will not give a reading. 

Press and hold the Range Button to return back to Auto Ranging. 

Relative Button

When taking measurements, you can utilize the Relative Button to get more accurate readings 
by removing the resistance of the test leads, for example. To activate this function, simply press 
the Relative Button. A small triangle (delta symbol) will appear on the display and the reading 
should change to zero. 

Press the Relative Button again to exit relative mode.

Hz/Duty Button

When using the Hz/Duty Cycle function on the multimeter, quickly switch between functions by 
pressing this button. You can also switch to measuring Hz while measuring other functions, like 
Voltage, for example, by pressing this button during measurement. 

Clamp Meter Attachment (Not Included)

Use a clamp meter attachment to measure currents, use the COM terminal for the black lead 
from the clamp meter and the Input terminal for the red lead from the clamp meter.

Multi-Function Socket (Included)

Use the multi-function socket to measure both Capacitors and Transistors. Be sure to correctly 
insert the multi-function socket into the COM and INPUT. the negative terminal on the multi-
function socket on the left side and the positive on the right side. 

DETAILED SPECIFICATIONS

Accuracy is guarantied for 1 year 23°C±5°C less than 80%RH

Содержание True RMS 6000

Страница 1: ...xposed metal Check the test leads for continuity Do not apply more than the rated voltage as marked on the Meter between the terminals or between any terminal and grounding The manual rotary switch sh...

Страница 2: ...en it has not been used for some time Replace the battery as soon as leaking appears A leaking battery will damage the Meter ELECTRICAL SYMBOLS AC Alternating Current Low Battery DC Direct Current Dio...

Страница 3: ...requency Yes Safety Compliances EN 61010 1 CAT III 600V CATII 1000V DC Voltage 600mV6 0 8 5 V 60V 600V 0 8 3 1000V 1 5 AC Voltage 600mV 1 2 8 6V 60V 600V 1 2 6 750V 1 2 8 Temperature 40 C 1370 C 40 F...

Страница 4: ...MULTIMETER DIAGRAM 1 Magnetic Hanger 2 LCD Screen 3 Function Buttons 4 Rotary Function Switch 5 10A Terminal 6 A mA Terminal 7 COM Terminal 8 INPUT Terminal 9 Silicone Sleeve 10 Multi Function Socket...

Страница 5: ...elative Mode GETTING TO KNOW YOUR DEVICE Select Button When using the rotary switch to select a multimeter function use the Select Button to further select the function This applies only to multifunct...

Страница 6: ...leads for example To activate this function simply press the Relative Button A small triangle delta symbol will appear on the display and the reading should change to zero Press the Relative Button a...

Страница 7: ...ection 600V DC AC RMS Max Input voltage 600V DC Measure DCV 1000V under CATII AC Voltage Auto ranging Range Resolution Accuracy 600mV 0 1mV 1 2 of rdg 8dgts 6V 1mV 60V 10mV 1 2 of rdg 6dgts 600V 100mV...

Страница 8: ...nge Resolution Accuracy 600 A 0 1 A 6000 A 1 A 60mA 10 A 600mA 100 A 0 8 of rdg 5dgts 6A 1mA 10A 10mA 1 5 of rdg 3dgts Overload Protection mA Jack F0 4A 600V fuse 10A Jack F10A 600V fuse Max Input Cur...

Страница 9: ...6000 A 1 A 60mA 10 A 600mA 100 A 1 5 of rdg 8dgts 10A 100mA 2 0 of rdg 10dgts Overload Protection mA jack F0 4A 600V fuse 10A jack F10A 600V fuse Max Input Current mA jack 400mA 10A jack 10A For meas...

Страница 10: ...A 2 5 10 200A 1mV 1A Diode and Continuity Range Introduction Remark The approximate forward voltage drop will be displayed Open circuit voltage about 1 5V The built in buzzer will sound if the resista...

Страница 11: ...UT jack 2 Set the function switch to V or V range Choose either Auto or Manual range using the Range Button 3 In manual range if the voltage magnitude to be measured is unknown beforehand select the h...

Страница 12: ...ce Measurement 1 Connect the black test lead to the COM jack and the red test lead to the INPUT jack 2 Set the function switch to range 3 Select either Auto or Manual range with the Range button In ma...

Страница 13: ...socket of the adapter 4 Read the LCD display for the approximate hFE value Temperature Measurement 1 Set the function switch to C F range 2 Use the Select Button to choose either Celsius or Fahrenhei...

Страница 14: ...clamp 5 The results will be displayed on the LCD display Note a Each time a measurement is taken make sure that only one cable is clamped and is in the center of the clamp jaws b The clamp can only t...

Страница 15: ...ion Socket DISPOSAL OF THIS ARTICLE If you at some point intend to dispose of this article please keep in mind that many of its components consist of valuable materials which can be recycled Please do...

Отзывы: