Astria MONTECITO MONTE Скачать руководство пользователя страница 21

CLEARANCE TO COMBUSTIBLES

The following clearances meet the minimum requirements for a safe 
installation;

Side wall: 

17” (324 mm) measured from the fireplace side

Ceiling:

  6’ 8”  (2,032 mm) measured from the base of the fireplace

Fireplace enclosure

  Bottom:  0”
  Side:  0” to spacer
  Back:  0” to spacer

  Top:  Do not fill the space above the fireplace with any material  
  (Except the wood framing.  See 

Page 9, Figure 8

)

Chimney:

  2” (50 mm)

Mantel:

  42”  (1067 mm) measured from the base of the fireplace.

Montecito™ Replacement Parts

Description

Part/Cat. No.

Blower (heat activated on/off pre-wired), UZY5

UZY5

Blower motor speed control (wall mount), VRUW

VRUW

Snap Disc, Blower 

VTU

Baffle refractory (2 pieces)

PR-ISO2205

Back refractory

PR-SR2618

Right side refractory

PR-SR2619D

Left side refractory

PR-SR2619G

Bottom refractory

PR-SR2201

Front refractory, right side

PR-SR2202D

Front refractory, left side

PR-SR2202G

Door handle

PR-SR1787

Hinge Assembly, Fireplace and Door

PR-SR2395TCE

Decorative Screw Caps, Black (2)

PR-SACMEFBK

Decorative Screw Caps, Brushed Nickel (2)

PR-SACMEFBN

Ceramic glass panel

PR-SR2222-1

Secondary air tube

PR-SR2271

Cast-iron Log Retainer Supports - Grate (2)

PR-SR2324

Cast Iron Log Retainer Bar

PR-SR2323

Gasket Kit, Glass, 

69” (1 x 5/16”) (steel and cast doors)

PR-SR1823H

Gasket Kit, Steel Door Frame, 

73” (5/8” dia.)

PR-SR1685D

Gasket Kit, Cast Door Frame, 

73” (5/8” dia.)

PR-SR1823G

Touch-up Paint, Aerosol, Black Metallic SBMB6309

H8159

Touch-up Paint, Charcoal (for hammered steel facade)

PR-P6201

Coupler, Outside Air (connects UZI to fireplace)

UZIAD

Coupler for AC Chimney (connects ACZI to fireplace)

H3274

Blower 250 CFM for central forced air kit, BISZY

BISZY

Blower variable speed control with decorative wall plate 

for (BISZY), VRUW

VRUW

Thermo-disk, on/off blower control (for BISZY), VTU

VTU

Blower to flexible pipe adaptor, BISAVF

BISAVF

Backdraft damper, BISBD

BISBD

Fireplace to Flex adaptor and 2 clamps, BISAF

BISAF

SPECIFICATIONS

REPLACEMENT PARTS LIST

Cat. No.

Model

H4841

Montecito

Product Reference Information

Weight

300 lbs

Height

36”

Width

36”

Depth

24-1/2”

Firebox W x H x D - measured in front

22” x 11-3/4” x 12”

Chimney Weight ASHT (6” dia)

6.25 lb per linear foot

Chimney Weight AC (6” dia.)

3.25 lb per linear foot

Chimney weight S-2100+ (6” dia.)

10.8 lb per linear foot

Contact an IHP dealer to obtain any of these parts. Never use substitute 

materials not approved by IHP. Use of non-approved parts can result 

in poor performance and safety hazards.

21

Содержание MONTECITO MONTE

Страница 1: ...t of glass doors Install this fireplace in a square and plumb condition using shims as necessary at sides and or bottom Install the fireplace only as described in these instructions This installation...

Страница 2: ...ensure that the air inlet to the fireplace is free from debris and any other obstructions that can block the entrance of air WARNING Neither the manufacturer nor the seller warrants smoke free operat...

Страница 3: ...e kit Required Order Separately See Page 20 UZY5 blower included in the fireplace VRUW Blower Speed Control included Outside air kit Included w Fireplace OPTIONAL EQUIPMENT Additional Equipment option...

Страница 4: ...g 10 to 20 minutes after reloading depending on the heat and on the moisture content of the wood Onceyouhavereachedthedesiredtemperature the air boost can be closed and the primary air set to a medium...

Страница 5: ...ces tar and other organic vapors which combine with expelled moisture to form creosote The creosote vapors condense in the relatively cool chimney flue of a slow burning fire As a result creosote resi...

Страница 6: ...door seal Close the door on the paper in at least eight points It is normal to feel only a slight amount of friction The door gasket does not need to be tight in all areas since a small amount of leak...

Страница 7: ...er the entire width of the fireplace The combustible floor in front of the fireplace mustbecoveredwithanon combustiblemate rial tile marble stone etc See Figures 7B Cold climate INSTALLATIONS Climates...

Страница 8: ...strations and photo graphs are not to scale consult installation instructions Product designs materials dimensions specifications colors and prices are subject to change or discontinuance without noti...

Страница 9: ...tside Walls Of Chase Solid Continuous Surface Outside Base Insulation Thermal Barrier 8 Level 7 2 1 m Min 6 8 2 m Min 8 2 4 m Level 42 1067mm 2 X 3 Min 51mm x 76mm Rock Board or Other Noncombustible F...

Страница 10: ...ure 12 Fireplace Blower The fireplace comes equipped with a heat acti vated blower It is located in the bottom of the fireplace towards the back It uses 120V and must be connected to the main electric...

Страница 11: ...a 5 diameter flexible pipe for the complete run up to thirty 30 feet and a 6 diameter pipe for a run of up to forty 40 feet The duct system must be installed respecting the following 1 Removetheplates...

Страница 12: ...hen offsets are used the pipe may not penetrate a ceiling or floor unless it is running vertical no 30 offsets Outside Intake Screw Opening Facing Down Wall Aluminum Tape Plastic Cover Insulation Flex...

Страница 13: ...oofs place the flashing under the upper shingles and on top of the lower shingles Nail the flashing to the roof using roofing nails 6 Place the spacers and the storm collar over the flashing and tight...

Страница 14: ...ne up the center of the hole Cut a hole for the chimney in the ceiling floor Frame this hole as described previously refer to section Chimney Instal lation Instructions 5 From below install a firestop...

Страница 15: ...22 mm 6 1 8 156 mm 11 280 mm 14 1 8 359 mm 16 7 8 429 mm 18 7 16 468 mm 23 584 mm 26 3 16 665 mm B 27 11 16 703 mm 33 1 2 851 mm 50 7 8 1292 mm 62 1 2 1588 mm 72 5 8 1845 mm 78 7 16 1992 mm 95 3 4 243...

Страница 16: ...bustible wall with the chimney at a 30 or 45 angle an angled firestop or wall radiation shield must be installed Only one is required NOTE 45 angle for Canada only RSMI45 In cold climate locations cli...

Страница 17: ...glass are maintained at hot temperatures see Refueling For Best Performance To clean the glass there are a number of specially designed cleaners Your authorized IHP dealer can recommend a suit able c...

Страница 18: ...CHIMNEY Offset Support Roof Support ASHT HT6103 6 dia 28feet 8 54m 29feet 8 84 m S 2100 HT6000 6 dia 18feet 5 49m 20feet 6 1 m AC 6 dia 40feet 12 19m 50feet 15 20 m Table 6 CHIMNEY CHASE AND MULTIPLE...

Страница 19: ...nry chimney 2 In the middle of the oval drill a hole in the masonry chimney at 30 3 Increase the size of the hole until a 30 Tubinox liner elbow can be easily slipped through 4 Slide the liner down fr...

Страница 20: ...7B26ZE45 H8949 Telescopic length 8 dia 15 to 26 7B26ZLA H8950 Adjustable length 8 dia 2 5 7B26ZL2A H8951 Length two 2 feet 8KL2 H8954 Length one 1 feet 8KL1 H8953 Wall radiation shield 8 I D 7B26ZR H...

Страница 21: ...ron Log Retainer Supports Grate 2 PR SR2324 Cast Iron Log Retainer Bar PR SR2323 Gasket Kit Glass 69 1 x 5 16 steel and cast doors PR SR1823H Gasket Kit Steel Door Frame 73 5 8 dia PR SR1685D Gasket K...

Страница 22: ...Steel Chimney 6 I D and 8 O D Double Wall Stainl Steel Listed to CAN UCL S604 and UL 103HT Description Part Cat No Lengths and Misc Chimney Components 8 length 6 Dia 6L8 6L8 12 length 6 Dia 6L12 6L12...

Страница 23: ...escription Cat Part No 6 Length 6 Dia 6LL6 6LL6 12 Length 6 Dia 6LL12 6LL12 24 Length 6 Dia 6LL24 6LL24 36 Length 6 Dia 6LL36 6LL36 48 Length 6 Dia 6LL48 6LL48 Adjustable Length 7 to 11 6 Dia 6L7A 6L7...

Страница 24: ...24 NOTES...

Страница 25: ...inder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves inserts and high efficiency EPA fireplaces are approved for burning dry s...

Страница 26: ...dealer for any questions or concerns Replacement parts See Page 21 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through you...

Отзывы: