Astria MONTECITO MONTE Скачать руководство пользователя страница 18

CHIMNEY SUPPORT INSTALLATION

Universal Roof Support

This support has three possible uses:

1. For ASHT+

*

 / 

*

 and S-2100+

*

 / 

*

, it must be used 

on a roof to support the chimney.

2. It may be used on a floor, ceiling or roof above an offset to support 

the chimney above the offset.

3. It may be used on a floor, ceiling or roof as a supplementary sup-

port. 

Table 6 

 gives maximum height of supported chimney.

NOTE

:  For the AC

*

 chimney, a support section must be used every forty 

(40) feet (12 m) instead of the universal roof support (ST).

For roof support installation, refer to the instructions provided with the 

support.

UNIVERSAL OFFSET SUPPORT INSTALLATION

This support is used to support the chimney above an offset.  When 

the chimney offset is used to traverse a wall this support may be used 

on the wall to support the chimney.  The maximum heights are given in 

Table 6

.  For offset support installation, refer to the instructions provided 

with the support. 

CHIMNEY MODEL 

*

MAXIMUM HEIGHT OF 

SUPPORTED CHIMNEY

Offset Support

Roof Support

ASHT+ /  (6” dia).

28 feet (8.54 m)

29 feet (8.84 m)

S-2100+ /  (6” dia).

18 feet (5.49 m)

20 feet (6.1 m)

AC  (6” dia).

40 feet (12.19 m)

50 feet (15.20 m)

Table  6

CHIMNEY CHASE AND MULTIPLE TERMINATIONS

For the purpose of this manual, a chimney chase is considered a part of 

the chimney system rather than part of a building.  The termination must 

be placed a minimum of 18” (460 mm) above the chase.

For installations where more than one chimney is located in the same 

chase or within the same area, we suggest that their terminations be 

separated by at least 16” (410 mm) horizontally, and 18” (460 mm) verti

-

cally.  This separation is to prevent smoke migrating from one chimney 

to another (see 

Figure 30

).

Figure 30

CHIMNEY ADAPTOR 

*

 (S-2100+ / ) CANADA ONLY

The fireplace is normally supplied with a chimney adaptor suitable for 

the ASHT+

*

 / 

*

 chimney.  If you want to install a S-2100+

*

 

*

 chimney, an adaptor is available (6UCA

*

(

Figure 31

)

.  A 

separate starter section will also be required if AC

*

 chimney is installed.

Figure 31

Chimney Adaptor - 

Canada only

18” (460 mm)

16” (410 mm)

18” (460 mm)

18” (460 mm)

16” (410 mm)

*

Available from Security Chimneys™ 

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

18

Содержание MONTECITO MONTE

Страница 1: ...t of glass doors Install this fireplace in a square and plumb condition using shims as necessary at sides and or bottom Install the fireplace only as described in these instructions This installation...

Страница 2: ...ensure that the air inlet to the fireplace is free from debris and any other obstructions that can block the entrance of air WARNING Neither the manufacturer nor the seller warrants smoke free operat...

Страница 3: ...e kit Required Order Separately See Page 20 UZY5 blower included in the fireplace VRUW Blower Speed Control included Outside air kit Included w Fireplace OPTIONAL EQUIPMENT Additional Equipment option...

Страница 4: ...g 10 to 20 minutes after reloading depending on the heat and on the moisture content of the wood Onceyouhavereachedthedesiredtemperature the air boost can be closed and the primary air set to a medium...

Страница 5: ...ces tar and other organic vapors which combine with expelled moisture to form creosote The creosote vapors condense in the relatively cool chimney flue of a slow burning fire As a result creosote resi...

Страница 6: ...door seal Close the door on the paper in at least eight points It is normal to feel only a slight amount of friction The door gasket does not need to be tight in all areas since a small amount of leak...

Страница 7: ...er the entire width of the fireplace The combustible floor in front of the fireplace mustbecoveredwithanon combustiblemate rial tile marble stone etc See Figures 7B Cold climate INSTALLATIONS Climates...

Страница 8: ...strations and photo graphs are not to scale consult installation instructions Product designs materials dimensions specifications colors and prices are subject to change or discontinuance without noti...

Страница 9: ...tside Walls Of Chase Solid Continuous Surface Outside Base Insulation Thermal Barrier 8 Level 7 2 1 m Min 6 8 2 m Min 8 2 4 m Level 42 1067mm 2 X 3 Min 51mm x 76mm Rock Board or Other Noncombustible F...

Страница 10: ...ure 12 Fireplace Blower The fireplace comes equipped with a heat acti vated blower It is located in the bottom of the fireplace towards the back It uses 120V and must be connected to the main electric...

Страница 11: ...a 5 diameter flexible pipe for the complete run up to thirty 30 feet and a 6 diameter pipe for a run of up to forty 40 feet The duct system must be installed respecting the following 1 Removetheplates...

Страница 12: ...hen offsets are used the pipe may not penetrate a ceiling or floor unless it is running vertical no 30 offsets Outside Intake Screw Opening Facing Down Wall Aluminum Tape Plastic Cover Insulation Flex...

Страница 13: ...oofs place the flashing under the upper shingles and on top of the lower shingles Nail the flashing to the roof using roofing nails 6 Place the spacers and the storm collar over the flashing and tight...

Страница 14: ...ne up the center of the hole Cut a hole for the chimney in the ceiling floor Frame this hole as described previously refer to section Chimney Instal lation Instructions 5 From below install a firestop...

Страница 15: ...22 mm 6 1 8 156 mm 11 280 mm 14 1 8 359 mm 16 7 8 429 mm 18 7 16 468 mm 23 584 mm 26 3 16 665 mm B 27 11 16 703 mm 33 1 2 851 mm 50 7 8 1292 mm 62 1 2 1588 mm 72 5 8 1845 mm 78 7 16 1992 mm 95 3 4 243...

Страница 16: ...bustible wall with the chimney at a 30 or 45 angle an angled firestop or wall radiation shield must be installed Only one is required NOTE 45 angle for Canada only RSMI45 In cold climate locations cli...

Страница 17: ...glass are maintained at hot temperatures see Refueling For Best Performance To clean the glass there are a number of specially designed cleaners Your authorized IHP dealer can recommend a suit able c...

Страница 18: ...CHIMNEY Offset Support Roof Support ASHT HT6103 6 dia 28feet 8 54m 29feet 8 84 m S 2100 HT6000 6 dia 18feet 5 49m 20feet 6 1 m AC 6 dia 40feet 12 19m 50feet 15 20 m Table 6 CHIMNEY CHASE AND MULTIPLE...

Страница 19: ...nry chimney 2 In the middle of the oval drill a hole in the masonry chimney at 30 3 Increase the size of the hole until a 30 Tubinox liner elbow can be easily slipped through 4 Slide the liner down fr...

Страница 20: ...7B26ZE45 H8949 Telescopic length 8 dia 15 to 26 7B26ZLA H8950 Adjustable length 8 dia 2 5 7B26ZL2A H8951 Length two 2 feet 8KL2 H8954 Length one 1 feet 8KL1 H8953 Wall radiation shield 8 I D 7B26ZR H...

Страница 21: ...ron Log Retainer Supports Grate 2 PR SR2324 Cast Iron Log Retainer Bar PR SR2323 Gasket Kit Glass 69 1 x 5 16 steel and cast doors PR SR1823H Gasket Kit Steel Door Frame 73 5 8 dia PR SR1685D Gasket K...

Страница 22: ...Steel Chimney 6 I D and 8 O D Double Wall Stainl Steel Listed to CAN UCL S604 and UL 103HT Description Part Cat No Lengths and Misc Chimney Components 8 length 6 Dia 6L8 6L8 12 length 6 Dia 6L12 6L12...

Страница 23: ...escription Cat Part No 6 Length 6 Dia 6LL6 6LL6 12 Length 6 Dia 6LL12 6LL12 24 Length 6 Dia 6LL24 6LL24 36 Length 6 Dia 6LL36 6LL36 48 Length 6 Dia 6LL48 6LL48 Adjustable Length 7 to 11 6 Dia 6L7A 6L7...

Страница 24: ...24 NOTES...

Страница 25: ...inder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves inserts and high efficiency EPA fireplaces are approved for burning dry s...

Страница 26: ...dealer for any questions or concerns Replacement parts See Page 21 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through you...

Отзывы: