6
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
General Information
900355-00, 06/2016
Innovative Hearth Products
Montebello
®
ST Direct-Vent Gas Fireplaces
APPLIANCE INSTALLATION, SERVICE, AND MAINTENANCE NOTICES
WARNING
Improper installation, adjustment, alteration, service or maintenance can cause injury or prop-
erty damage. Refer to this manual. For assistance or additional information consult a quali-
fied installer, service agency or the gas supplier.
AVERTISSEMENT
Une installation, un réglage,une modification, une réparation ou un entretien mal effectué
peut causer des dommages matériels ou des blessures. Voir la notice de l’utilisateur qui ac-
compagne l’appareil. Pour de l’aide ou des renseignements supplémentaires, consultez un
installateur, un technicien agréé ou le fournisseur de gaz.
Only trim kit(s) supplied by the manufacturer shall be used in the installation of this fireplace.
Seules des portes certifiées pour cet appareil doivent être utilisées.
These appliances must not be connected to a chimney or flue serving a separate solid fuel burn-
ing appliance.
Any change to this appliance and/or its operating controls is dangerous. Improper installation
or use of this appliance can cause serious injury or death from fire, burns, explosion or carbon
monoxide poisoning.
CARBON MONOXIDE POISONING: Early signs of carbon monoxide poisoning are similar to the
flu with headaches, dizziness and/or nausea. If you have these signs, obtain fresh air immedi-
ately. Turn off the gas supply to the appliance and have it serviced by a qualified professional,
as it may not be operating correctly. Some people are more affected by carbon monoxide than
others, including pregnant women, people with heart or lung disease or anemia, those under
the influence of alcohol, and those at high altitudes.
Turn off gas and electrical power to the appliance and allow it to cool before cleaning or servic-
ing the appliance.
If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier
for this appliance.
Si l’écran est endommagé, il doit être remplacé par celui fournit par le fabricant de cet
appareil.
For use with barrier Part No. J7422. Follow installation instructions.
Reinstall any barrier removed before operating the appliance. The barrier is designed to re-
duce the risk of burns from hot glass. Do not operate the appliance without the barrier installed.