background image

Astria.US.com

127331-01A

14

POSSIBLE CAUSE

1. Buildup of dust or dirt on burner

1. At cold start; flame might not be too vis-

ible

2. Burner out of fuel

3. Fuel tank not fully engaged

4. Incorrect fuel is used

5. Shutoff plate not in the full open position

6. If re-lighting while burner is hot, fumes/

vapor accumulated around burner

1. Shutoff plate is not fully closed

2. Shutoff plate not properly closed allowing 

fumes/vapor to build up

1. Draft from air or fan

2. Burner running out of fuel

1. Battery power is low

2. Loose wire connections

REMEDY

1. Clean burner

1. Check for heat around burner area to 

make sure flame is present

2. Refill fuel tank

3. Check connection between fuel tank and 

fuel hose 

4. Use specified fuel. FP1 or FP2 Denatured 

Ethanol only

Note: You can purchase these types of 

ethanol fuel by contacting PHARMCO-

AAPER at 800-456-1017 or www.pharm-

coaaper.com

5. Slide shutoff plate fully open

6. Wait at least 10 minutes to allow fumes/

vapor to settle. Relight burner.

1. Slide shutoff plate evenly making sure 

plate is fully closed

2. Slide shutoff plate evenly making sure 

plate is fully closed

1. Remove or relocate fan away from appli-

ance

2. Refill fuel tank

1. Replace battery

2. Check and secure all wire connections 

(see To Relight  Appliance, page 11).

OBSERVED PROBLEM

Slight smoke or odor during  operation

Burner will not light

Flame will not extinguish when turned off

Sporadic or uneven flame

No spark on igniter

TROUBLESHOOTING

 WARNING: Turn off appliance and let cool before servicing. Only a qualified service person should service 

and repair appliance.

Note:

 All troubleshooting items are listed in order of operation.

Содержание london lights

Страница 1: ...is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ventilation section on page 5 of this manual WARNING If the information in these i...

Страница 2: ...en people with heart or lung disease or anemia those under the influence of alcohol and those at high altitudes Make certain you read and understand all warnings Keep this manual for reference It is y...

Страница 3: ...ot convertible for use with other gases 2 Always keep a fire extinguisher CLASS B near the appliance 3 Never refill appliance fuel reservoir when appliance is operating or still hot 4 This appliance s...

Страница 4: ...e vent ing There is no heat loss out a vent or up a chimney Heat is generated by real flames This appliance is designed for vent free operation It has been tested and approved to UL 1370 standard for...

Страница 5: ...u must provide additional fresh air See Ventilation Air From Outdoors page 6 If your home does not meet all of the three criteria above proceed to Determining Fresh Air Flow For Appliance Location Con...

Страница 6: ...nt openings one within 12 of the ceiling and one within 12 of the floor on the wall connecting the two spaces see options 1 and 2 Figure 2 You can also remove door into adjoining room see option 3 Fig...

Страница 7: ...CES WARNING Maintain the minimum clearances If you can provide greater clearances from floor ceiling and adjoining wall Carefully follow the instructions below This will ensure safe instal lation CLEA...

Страница 8: ...wn in this manual INSTALLING REMOVING HOOD 1 Loosen screws at top of face opening and slide hood through screws as shown in Figure 7 2 Tighten screws securing hood to fireplace 3 To remove reverse the...

Страница 9: ...Astria US com 127331 01A 9 INSTALLATION Continued 18 3 4 37 3 4 40 3 4 44 3 16 55 3 16 16 1 4 55 3 16 47 1 8 1 1 2 22 7 16 1 11 16 4 13 16 13 1 8 1 14 1 4 5 8 5 8 Figure 8 LONDON LIGHTS Dimensions...

Страница 10: ...Reservoir Figure 9 Filling the Fuel Tank Reservoir FILLING THE FUEL TANK RESERVOIR 1 Open bottom access panel Note Use the index finger of both hands when opening access panel by inserting them thru...

Страница 11: ...y periodically Replace battery if needed by unscrewing battery compartment cap see Figure 10 TO TURN OFF APPLIANCE 1 Slide shut off plate fully closed by pushing plate handle in com pletely and make s...

Страница 12: ...rd you Insert bottom flange of screen door into the retaining channel at the bottom of firebox see Figure 12 Make sure door is center with firebox opening 2 Tilt top of door up toward top of firebox 3...

Страница 13: ...Astria US com 127331 01A 13 CLEANING AND MAINTENANCE Continued Figure 14 Glass Nuggets Installation Nuggets Pan Burner Fuel Tray Access Door...

Страница 14: ...FP1 or FP2 Denatured Ethanol only Note You can purchase these types of ethanol fuel by contacting PHARMCO AAPER at 800 456 1017 or www pharm coaaper com 5 Slide shutoff plate fully open 6 Wait at leas...

Страница 15: ...so contact IHP at 1 800 655 2008 When calling please have your model and serial numbers of your ap pliance ready You can also visit our web site at Astria US com ACCESSORIES NOTICE All accessories ma...

Страница 16: ...yle 3 16 1 11 126478 01 Fuel Tank Release Rod 1 12 126480 01 External Retaining Ring 1 13 17373 Spring Tank Release 1 14 111733 01 Washer Black M6 1 15 127000 01 Fuel Supply Line 9 5 1 16 126474 01 Cl...

Страница 17: ...6 Screw 8 32 x 1 2 10 126559 01 Switch Momentary 1 11 126472 01 Bracket Spark Ignitor 1 12 11201 8 32 Hex Nut 2 13 125763 01 Bracket corner Wall 4 14 125813 02 Wall Side Porcelain 2 15 125814 01 Wall...

Страница 18: ...____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______...

Страница 19: ...produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product d d...

Страница 20: ...tion tag ____________________ Date Purchased _______________________ Keep receipt for warranty verification Innovative Hearth Products reserves the right to make changes at any time without notice in...

Отзывы: