Astria Fireplaces Sheridan18NM Скачать руководство пользователя страница 4

Astria.us.com

126810-01B

4

2.  Do not place propane/LP supply tank(s) inside 

any structure. Locate propane/LP supply 
tank(s) outdoors (propane/LP units only).

3.  If you smell gas

• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not 

use any phone in your building

• immediately call your gas supplier from 

a neighbor’s phone. Follow the gas sup-
plier’s instructions

• if you cannot reach your gas supplier, 

call the fi re department

4.  This heater shall not be installed in a 

bedroom or bathroom unless installed 
as a vented appliance. See 

Installing 

Damper Clamp Accessory for Vented 
Operation,

 

Page 13

.

5. 

WARNING: Before installing in a solid 
fuel burning fi replace, the chimney fl ue 
and  fi rebox must be cleaned of soot, 
creosote, ashes and loose paint by a 
qualifi ed chimney cleaner.

 Creosote will 

ignite if highly heated. A dirty chimney fl ue 
may create an distribute soot within the 
house. Inspect chimney fl ue for damage. 
If damaged, repair fl ue before operating 
heater.

6.  Do not burn solid fuel in a masonry or 

UL127 factory-built fi replace in which a 
vent-free room heater is installed.

7.  If fi replace has glass doors, never operate 

this heater with glass doors closed. If you 

operate heater with doors closed, heat 
buildup inside fi replace will cause glass to 
burst. Make sure there are no obstructions 
across openings of fi replace.

8.  To prevent the creation of soot, follow the 

instructions in 

Cleaning and Maintenance

Page 21

.

9.  Before using furniture polish, wax, carpet 

cleaner or similar products, turn heater 
off. If heated, the vapors from these prod-
ucts may create a white powder residue 
within burner box or on adjacent walls or 
furniture.

10. This heater needs fresh, outside air ven-

tilation to run properly. This heater has an 
oxygen depletion sensing (ODS) pilot light 
safety system. The ODS shuts down the 
heater if not enough fresh air is available. 
See 

Air for Combustion and Ventilation

Page 6

. If heater keeps shutting off, see 

Troubleshooting

Page 22

.

11.  Do not run heater

• where  fl ammable liquids or vapors are 

used or stored

• under dusty conditions

12. Do not use this heater to cook food or burn 

paper or other objects.

13. Do not use this room heater if any part 

has been under water. Immediately call a 
qualifi ed service technician to inspect the 
room heater and to replace any part of the 
control system and any gas control which 
has been under water. 

14. Do not operate heater if any log is broken. 

Do not operate heater if a log is chipped 
(dime-sized or larger). 

15. Turn heater off and let cool before servic-

ing or repairing. Make sure the selector 
switch is in the OFF position. Only a quali-
fi ed service person should install, service 
or repair heater.

16. Make sure selector switch is in the OFF 

position when you are away from home 
for long periods of time.

17. This heater does not need to be con-

nected to any external electrical source.

18. To prevent performance problems, do not 

use propane/LP fuel tank of less than 100 
lb. capacity (propane/LP units only).

19. Provide adequate clearances around air 

openings.

SAFETY

Continued

Installation and repair should be 
done by a qualifi ed service person. 
The appliance should be inspected 
before use and at least annually by 
a professional service person. More 
frequent cleaning may be required 
due to excessive lint from carpeting, 
bedding material, etc. It is imperative 
that control compartments, burners, 
and circulating air passageways of 
the appliance be kept clean.

1. WARNING: 

This appliance is only for 

use with the type of gas indicated on 
the rating plate. This appliance is not 
convertible for use with other gases. 

f i r e - p a r t s . c o m

Содержание Sheridan18NM

Страница 1: ...it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ventilation section on Page 6 of this manual Installation and Operation Instruc...

Страница 2: ...ANSI Z21 11 2 Exception DO NOT install this appliance in a factory built fireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs WARNING This i...

Страница 3: ...proper operation of this fireplace WARNING Do not allow fans to blow directly into the heater Avoid any drafts that alter burner flame patterns Ceiling fans can create drafts that alter burner flame...

Страница 4: ...utside air ven tilation to run properly This heater has an oxygen depletion sensing ODS pilot light safety system The ODS shuts down the heater if not enough fresh air is available See Air for Combust...

Страница 5: ...et assembly from carton NOTE Do not pick up assembly by logs This could damage heater Always handle assembly by grate CAUTION Donotremovethe data plates from the grate as sembly The data plates contai...

Страница 6: ...ill ensure proper venting of vented fuel burning appliances PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Com bustion and Ventilatio...

Страница 7: ...__ volume of space x 20 Maximum Btu Hr the space can support Example 2560 cu ft volume of space x 20 51 200 maximum Btu Hr the space can sup port 3 Add the Btu Hr of all fuel burning appliances in the...

Страница 8: ...he outdoors or spaces open to the outdoors These spaces include attics and crawl spaces Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of ve...

Страница 9: ...hing or other flammable objects are less than 42 from the front top or sides of the heater in high traffic areas in windy or drafty areas CAUTION This appliance cre ates warm air currents These cur re...

Страница 10: ...hood accessory 24 Model Only See Figure 5 for minimum clearances Figure 5 Heat Resistant Material Slate Marble Tile etc Above Fireplace Noncombustible Material Distance A Requirements for Safe Instal...

Страница 11: ...fireplace opening and mantel shelf If you do not meet the clearances listed below you will need a hood Determining Minimum Mantel Clearance If you meet minimum clearance between mantel shelf and top...

Страница 12: ...mbustible flooring see Figure 9 14 Min Combustible Material Noncombustible Material Hearth 5 Min Combustible Material NOTICE Surface temperatures ofadjacentwallsandmantelsbe comehotduringoperation Wal...

Страница 13: ...per open Installation instructions are included with clamp accessory See chart below for minimum permanent flue opening you must provide Attach damper clamp so the minimum permanent flue open ing will...

Страница 14: ...ne LP gas equipment shutoff valve test gauge connection sediment trap tee joint pipe wrench approved flexible gas line with gas connec tor if allowed by local codes provided For propane LP units the i...

Страница 15: ...old gas control with wrench when connecting it to gas piping and or fittings WARNING Testallgaspiping and connections internal and external to unit for leaks after installing or servicing Correct all...

Страница 16: ...gas valve located on or near gas meter for natural gas or using compressed air 3 Check all joints from gas meter to equip ment shutoff valve for natural gas or propane LP supply to equipment shutoff v...

Страница 17: ...tructions exactly a fire or explosion may result causing property damage per sonal injury or loss of life WARNING Damper handle will be hot if heater has been running NOTICE Duringinitialoperation of...

Страница 18: ...ntrol knob counterclockwise to the ON posi tion 10 Wait one minute and switch selector switch to the ON position to light burners 11 Set flame adjustment knob to any level between HI and LO 12 To leav...

Страница 19: ...cell for LCD both included Remote receiver requires 4 AA 1 5V alkaline batteries included Operating Frequency 303 875 MHz 1 After lighting let pilot flame burn for about one minute Turn control knob...

Страница 20: ...flame pattern and burner flame patterns often PILOT FLAME PATTERN Figure 20 shows a correct pilot flame pattern Figure 21 shows an incorrect pilot flame pat tern The incorrect pilot flame is not touch...

Страница 21: ...three months during operation and have heater inspected yearly by a qualified service person We also recommend that you keep the burner tube clean and free of dust and dirt We rec ommend using compres...

Страница 22: ...inched by any metal or tubing Keep igniter cable dry 3 Replace battery 4 Replace igniter cable 5 Replace electronic igniter 6 Replace pilot assembly When igniter button is pressed there is spark at OD...

Страница 23: ...eaning and Mainte nance Page 21 or re place ODS pilot assembly 6 Hand tighten until snug then tighten 1 4 turn more 7 Replace pilot assembly 8 Replace control valve Burner does not light after ODS pil...

Страница 24: ...ked by local natural or propane LP gas company 3 Observe minimum instal lation clearances see Pages 9 through 12 4 Clean burner see Clean ing and Maintenance Page 21 or replace burner orifice White po...

Страница 25: ...supply propane LP only 3 Gas leak See Warning statement at top of page 1 Open window to ventilate room Stop using odor causing products while heater is running 2 Refill supply tank pro pane LP only 3...

Страница 26: ...o low If so contact your local propane LP or natural gas supplier TECHNICAL SERVICE You may have further questions about instal lation operation or troubleshooting Please contact your IHP dealer for a...

Страница 27: ...4NM F0093 Sheridan24PM 7 20 3 6 9 4 6 1 25 8 5 23 24 10 11 25 21 12 13 16 10 6 14 2 15 18 17 22 19 Installed in BTB Models Only 17 Remote Control and Receiver WARNING Failure to po sition the parts in...

Страница 28: ...2 Valve LP 1 12 J5239 Valve Bracket 1 13 J4596 Electronic Igniter 1 14 J3840 Control Knob Extension 1 15 J3841 Control Knob Extension 1 16 J3656 Fan Switch 1 17 J4871 Remote Control and Receiver 1 18...

Страница 29: ...GA6050 For all models Helps deflect heat away from mantel or wall above fireplace Fits openings 28 to 48 wide DECORATIVE ASH BED CONTROL COVER KIT SIX PACK Cat No F1759 Model CDABKA 6 DECORATIVE ASH B...

Страница 30: ...ote is programmable for your convenience and has a large bright LCD Touch Screen for easy use MODE SET PROG ON OFF REMOTE AND RECEIVER WITH WHITE WALL PLATE Cat No F2236 Model RCKIT 4001 For all Remot...

Страница 31: ...o the Product will produce excessive temperatures and could result in a re hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided wit...

Страница 32: ...butor for fireplace code information Printed in U S A 2014 Innovative Hearth Products P N 126810 01 Rev B 05 2017 1508 Elm Hill Pike Suite 108 Nashville TN 37210 Astria us com Record the following imp...

Отзывы: