SAFETY

Continued

IMPORTANT: Read this owner’s 
manual carefully and completely 
before trying to assemble, operate or 
service this heater. Improper use of 
this heater can cause serious injury 
or death from burns, fi re, explosion, 
electrical shock and carbon monox-
ide poisoning.

 WARNING: Any change to this 

heater or its controls can be dan-
gerous.

 WARNING: Do not use a blower 

insert, heat exchanger insert or other 
accessory not approved for use with 
this heater. 

Carbon Monoxide Poisoning

: Early signs of 

carbon monoxide poisoning resemble the fl u, 
with headaches, dizziness or nausea. If you 
have these signs, the fi replace may not be 
working properly. Get fresh air at once! Have 
fi replace serviced. Some people are more af-
fected by carbon monoxide than others. These 
include pregnant women, people with heart 
or lung disease or anemia, those under the 
infl uence of alcohol and those at high altitudes.

Natural and Propane/LP gases

: Natural and 

Propane/LP gases are odorless. An odor-
making agent is added to these gases. The 
odor helps you detect a gas leak. However, the 
odor added to the gas can fade. Gas may be 
present even though no odor exists.
Make certain you read and understand all warn-
ings. Keep this manual for reference. It is your 
guide to safe and proper operation of this fi replace. 

WARNING: Do not allow fans to 

blow directly into the heater. Avoid 
any drafts that alter burner fl ame 
patterns. Ceiling fans can create 
drafts that alter burner fl ame  pat-
terns. Altered burner patterns can 
cause sooting.

Due to high temperatures, the ap-
pliance should be located out of 
traffi c and away from furniture and 
draperies.

Do not place clothing or other 
fl ammable material on or near the 
appliance. Never place any objects 
on the heater.

Heater base assembly becomes very 
hot when running heater. Children 
and adults should be alerted to the 
hazard of high surface temperature 
and should stay away to avoid 
burns or clothing ignition. Heater 
will remain hot for a time after shut-
down. Allow surface to cool before 
touching.

Young children should be care-
fully supervised when they are in 
the same room with the appliance. 
When using the hand-held remote 
accessory, keep selector switch in 
the OFF position to prevent children 
from turning on burners with remote.

WARNING: Do not place log 

scraps or volcanic stone on burner.

You must operate this heater with 
a fi replace doors or screen in place 
and fully closed. Unless provided 
by other means, screens shall have 
openings for introduction of com-
bustion air.

Keep the appliance area clear and 
free from combustible materials, 
gasoline and other fl ammable  va-
pors and liquids.

Solid-fuels shall not be burned in a 
fi replace in which an unvented room 
heater is installed.

f i r e - p a r t s . c o m

Содержание Sheridan18NM

Страница 1: ...it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ventilation section on Page 6 of this manual Installation and Operation Instruc...

Страница 2: ...ANSI Z21 11 2 Exception DO NOT install this appliance in a factory built fireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs WARNING This i...

Страница 3: ...proper operation of this fireplace WARNING Do not allow fans to blow directly into the heater Avoid any drafts that alter burner flame patterns Ceiling fans can create drafts that alter burner flame...

Страница 4: ...utside air ven tilation to run properly This heater has an oxygen depletion sensing ODS pilot light safety system The ODS shuts down the heater if not enough fresh air is available See Air for Combust...

Страница 5: ...et assembly from carton NOTE Do not pick up assembly by logs This could damage heater Always handle assembly by grate CAUTION Donotremovethe data plates from the grate as sembly The data plates contai...

Страница 6: ...ill ensure proper venting of vented fuel burning appliances PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Com bustion and Ventilatio...

Страница 7: ...__ volume of space x 20 Maximum Btu Hr the space can support Example 2560 cu ft volume of space x 20 51 200 maximum Btu Hr the space can sup port 3 Add the Btu Hr of all fuel burning appliances in the...

Страница 8: ...he outdoors or spaces open to the outdoors These spaces include attics and crawl spaces Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of ve...

Страница 9: ...hing or other flammable objects are less than 42 from the front top or sides of the heater in high traffic areas in windy or drafty areas CAUTION This appliance cre ates warm air currents These cur re...

Страница 10: ...hood accessory 24 Model Only See Figure 5 for minimum clearances Figure 5 Heat Resistant Material Slate Marble Tile etc Above Fireplace Noncombustible Material Distance A Requirements for Safe Instal...

Страница 11: ...fireplace opening and mantel shelf If you do not meet the clearances listed below you will need a hood Determining Minimum Mantel Clearance If you meet minimum clearance between mantel shelf and top...

Страница 12: ...mbustible flooring see Figure 9 14 Min Combustible Material Noncombustible Material Hearth 5 Min Combustible Material NOTICE Surface temperatures ofadjacentwallsandmantelsbe comehotduringoperation Wal...

Страница 13: ...per open Installation instructions are included with clamp accessory See chart below for minimum permanent flue opening you must provide Attach damper clamp so the minimum permanent flue open ing will...

Страница 14: ...ne LP gas equipment shutoff valve test gauge connection sediment trap tee joint pipe wrench approved flexible gas line with gas connec tor if allowed by local codes provided For propane LP units the i...

Страница 15: ...old gas control with wrench when connecting it to gas piping and or fittings WARNING Testallgaspiping and connections internal and external to unit for leaks after installing or servicing Correct all...

Страница 16: ...gas valve located on or near gas meter for natural gas or using compressed air 3 Check all joints from gas meter to equip ment shutoff valve for natural gas or propane LP supply to equipment shutoff v...

Страница 17: ...tructions exactly a fire or explosion may result causing property damage per sonal injury or loss of life WARNING Damper handle will be hot if heater has been running NOTICE Duringinitialoperation of...

Страница 18: ...ntrol knob counterclockwise to the ON posi tion 10 Wait one minute and switch selector switch to the ON position to light burners 11 Set flame adjustment knob to any level between HI and LO 12 To leav...

Страница 19: ...cell for LCD both included Remote receiver requires 4 AA 1 5V alkaline batteries included Operating Frequency 303 875 MHz 1 After lighting let pilot flame burn for about one minute Turn control knob...

Страница 20: ...flame pattern and burner flame patterns often PILOT FLAME PATTERN Figure 20 shows a correct pilot flame pattern Figure 21 shows an incorrect pilot flame pat tern The incorrect pilot flame is not touch...

Страница 21: ...three months during operation and have heater inspected yearly by a qualified service person We also recommend that you keep the burner tube clean and free of dust and dirt We rec ommend using compres...

Страница 22: ...inched by any metal or tubing Keep igniter cable dry 3 Replace battery 4 Replace igniter cable 5 Replace electronic igniter 6 Replace pilot assembly When igniter button is pressed there is spark at OD...

Страница 23: ...eaning and Mainte nance Page 21 or re place ODS pilot assembly 6 Hand tighten until snug then tighten 1 4 turn more 7 Replace pilot assembly 8 Replace control valve Burner does not light after ODS pil...

Страница 24: ...ked by local natural or propane LP gas company 3 Observe minimum instal lation clearances see Pages 9 through 12 4 Clean burner see Clean ing and Maintenance Page 21 or replace burner orifice White po...

Страница 25: ...supply propane LP only 3 Gas leak See Warning statement at top of page 1 Open window to ventilate room Stop using odor causing products while heater is running 2 Refill supply tank pro pane LP only 3...

Страница 26: ...o low If so contact your local propane LP or natural gas supplier TECHNICAL SERVICE You may have further questions about instal lation operation or troubleshooting Please contact your IHP dealer for a...

Страница 27: ...4NM F0093 Sheridan24PM 7 20 3 6 9 4 6 1 25 8 5 23 24 10 11 25 21 12 13 16 10 6 14 2 15 18 17 22 19 Installed in BTB Models Only 17 Remote Control and Receiver WARNING Failure to po sition the parts in...

Страница 28: ...2 Valve LP 1 12 J5239 Valve Bracket 1 13 J4596 Electronic Igniter 1 14 J3840 Control Knob Extension 1 15 J3841 Control Knob Extension 1 16 J3656 Fan Switch 1 17 J4871 Remote Control and Receiver 1 18...

Страница 29: ...GA6050 For all models Helps deflect heat away from mantel or wall above fireplace Fits openings 28 to 48 wide DECORATIVE ASH BED CONTROL COVER KIT SIX PACK Cat No F1759 Model CDABKA 6 DECORATIVE ASH B...

Страница 30: ...ote is programmable for your convenience and has a large bright LCD Touch Screen for easy use MODE SET PROG ON OFF REMOTE AND RECEIVER WITH WHITE WALL PLATE Cat No F2236 Model RCKIT 4001 For all Remot...

Страница 31: ...o the Product will produce excessive temperatures and could result in a re hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided wit...

Страница 32: ...butor for fireplace code information Printed in U S A 2014 Innovative Hearth Products P N 126810 01 Rev B 05 2017 1508 Elm Hill Pike Suite 108 Nashville TN 37210 Astria us com Record the following imp...