53

Continuous Pilot Ignition Switch

Fireplaces with an electronic gas valve have a continuous pilot ignition (CPI) controlled by the remote

This switch allows the pilot to be switched from intermittent mode to continuous mode:

•  Intermittent Mode—The pilot is extinguished when the fireplace is OFF.

•  Continuous Mode—The pilot stays ON when the fireplace is OFF.

In periods of extreme cold, condensation may form on the glass door when the fireplace is OFF and the pilot is in 

intermittent mode. Also, with the pilot in intermittent mode, the fireplace may 

cycle startup

 (i.e., the pilot and burner ignite, 

but the burner extinguishes and reignites several times until the flue reaches the temperature for proper drafting).

•  To save energy—switch to intermittent mode. 

•  For a standing pilot that will help prevent glass door condensation and cycle startup—switch to continuous mode.

NOTE: Continuous mode is indicated by a pilot that comes ON and remains lit when the fireplace is OFF.

Traditional Only: Installing the Firebox Liners

1. 

Remove the three (3) optional firebox liner panels from the packing materials if purchased.

2. 

Carefully position the rear panel, upper edge first, in the firebox against the rear wall.

3. 

While holding the rear panel, carefully position the left side panel in the firebox. 

4. 

Carefully position the right side panel in the firebox.

NOTE: Do not force the panels. Excessive force may cause breakage. If the panels are correctly positioned, they will 

fit snugly in place.

 

Contemporary Only: Installing the Glass Media

1. 

Install the glass media in the recessed area between the front and rear floors. See 

Figure 43B

 on 

Page 54

.

NOTE: 35” fireplaces require less than a full bag of glass media. 40” fireplaces require an entire bag of media.

2. 

Spread the glass media in a thin layer, evenly over the burner. CAUTION: Ensure the glass media does not fall 

inside the bracket or through the pilot hole 

(see

 

Figure 43B

 

on

 

Page 54).

NOTE: Do NOT mound the media.

Installing the Backup Batteries

With a battery backup, electronic fireplaces can automatically switch to battery power. In the event of a power outage, this 

allows ON/OFF operation (without blower functionality). Install new batteries before every burn season. 

1.  Open the lower control panel, and locate the battery holder 

(See Figure 39)

.

2.  Install four (4) AA batteries in the battery holder.

3.  Close the lower control panel.

Some parts have been removed for clarity

Figure 39 - Battery Holder (in control compartment)

Figure 40 - Switches (in control compartment)

Battery

Holder

Learn Switch is for programming the remote (see 

instructions provided with the remote control)

IPI Switch is for continuous pilot or standing pilot

Hi-Low Switch controls the main burner flame height

ON/OFF Switch turns the burner on and off

Содержание Scorpio Series

Страница 1: ...us ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L installationetl entretiendoiventêtreassuréspar un installateur ou un service d entretien qualifié ou par le fournisseur de gaz INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference Installateur Laissez cette notice avec l appareil Consommateur Conservez cette notice pour consul...

Страница 2: ...RE EL VIDRIO CALIENTE CAUSARÁ QUEMADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NIÑOS DEBEN NUNCA TOCAR EL VIDRIO L écran pare étincelles fourni avec ce foyer réduit le risque de brûlure en cas de contact accidentel avec la vitre chaude et doit être installé pour la protection Des enfants et Des personnes à risques Una barrera diseñada para reducir el riesgo de quemaduras desde la mirilla v...

Страница 3: ...s graves si se toca Mantenga a los niños alejados de la chimenea en funcionamiento Supervise en forma cercana a los niños en cualquier cuarto donde haya una chimenea funcionando para impedir el contacto con el vidrio Mantenga la ropa mobiliario gasolina y otros líquidos inflamables alejados de la chimenea Aún después de haber apagado el gas las superficies de la chimenea permanecen extremadamente ...

Страница 4: ...to Combustibles 15 Wall Finishes Surrounds Mantels 16 Installation Preparation 16 Installation Installation Sequence 17 Construct the Fireplace Framing 17 Prepare the Fireplace Top Spacers 19 Route the Gas Supply Line to the Fireplace 19 Determine Vent Setup in the Combination Venting Unit 20 Install Non Combustible Front Fireboard Standoff 20 Rough in the Electrical Supply if Needed 21 Place the ...

Страница 5: ... subir des brûlures s ils viennent en contact avec la surface chaude Il est recommandé d installer une barrière physique si des personnes à risques habitent la maison Pour empêcher l accès à un foyer ou à un poêle installez une barrière de sécurité cette mesure empêchera les tout petits les jeunes enfants et toute autre personne à risque d avoir accès à la pièce et aux surfaces chaudes 7 Tout écra...

Страница 6: ...angerous Improper installation or use of this appliance can cause serious injury or death from fire burns explosion or carbon monoxide poisoning CARBON MONOXIDE POISONING Early signs of carbon monoxide poisoning are similar to the flu with headaches dizziness and or nausea If you have these signs obtain fresh air immediately Turn off the gas supply to the appliance and have it serviced by a qualif...

Страница 7: ... combinations of fuels will degrade the performance of this system and may be dangerous Provide adequate clearances around air openings and adequate accessibility clearance for service and proper operation Never obstruct the front openings of the appliance These appliances are designed as supplemental heaters Therefore it is advisable to have an alternate primary heat source when installed in a dw...

Страница 8: ...n qualifié L appareil devrait faire l objet d une inspection par un technicien professionnel avant d être utilisé et au moins une fois l an par la suite Des nettoyages plus fréquents peuvent être nécessaires si les tapis la literie et cetera produisent une quantité importante de pous sière Il est essentiel que les compartiments abritant les commandes les brûleurs et les conduits de circulation d a...

Страница 9: ...n is provided on the valve stem see Figure 1A The inlet line gas pressure test point is shown in Figure 1B The control valves have a 3 8 10 mm NPT thread inlet and outlet side of the valve Propane tanks are at pressures that will cause damage to valve components Verify that the tanks have step down regulators to reduce the pressure to safe levels Some parts have been removed for clarity 1 8 Inlet ...

Страница 10: ...f altitude IN CANADA CAN CGA 2 17 M91 HIGH ALTITUDE THE CONVERSION SHALL BE CARRIED OUT BY A MANUFACTURER S AUTHORIZED REPRESENTATIVE IN ACCORDANCE WITH THE REQUIREMENTS OF THE MANUFACTURER PROVINCIAL OR TERRITORIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE CAN CGA B149 1 OR CAN CGA B149 2 INSTALLATION CODES COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS These appl...

Страница 11: ...floor on which fireplace rests if floor is above ground level Gas line holes and other openings should be caulked or stuffed with unfaced fiberglass insulation NOTE Do not use loose or blown in insulation in the cavity surrounding the fireplace If the fireplace is being installed on a cement slab in cold climates a sheet of plywood or other raised platform can be placed underneath to prevent condu...

Страница 12: ... conditioning ducting These direct vent fireplaces are uniquely suited for installations requiring a utility shelf positioned directly above the fireplace Utility shelves like these are commonly used for locating television sets and decorative plants Be aware that this is a heat producing fireplace Objects placed above the unit are exposed to elevated temperatures Do not insulate the space between...

Страница 13: ...to 18 12 7 0 ft 2 13 m 18 12 to 20 12 7 5 ft 2 29 m 20 12 to 21 12 8 0 ft 2 44 m 12 X Roof pitch is X 12 2 ft minimum 2 ft minimum Lowest discharge opening H H minimum height from roof to lowest discharge opening of vent Horizontal overhang Vertical wall Vent termination Storm collar Concentric vent pipe Flashing 1 26mm minimum clearance to combustibles TERMINATION HEIGHTS FOR VENTS ABOVE FLAT OR ...

Страница 14: ...to nonmechanical air supply inlet to building or the combustion air inlet to any other fireplace 6 150 mm for fireplaces 10 000 Btu h 3 kW 9 230 mm for fireplaces 10 000 Btu h 3 kW and 50 000 Btu h 15 kW 12 300 mm for fireplaces 50 000 Btu h 15 kW 6 150 mm for fireplaces 10 000 Btu h 3 kW 12 300 mm for fireplaces 10 000 Btu h 3 kW K Clearance to a mechanical air supply inlet 36 910 mm above if wit...

Страница 15: ... other combustible material other than wood flooring the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance Hearth Extension A hearth extension is not required with this fireplace If a hearth extension is used do not block the lower control compartment door Any hearth extension used is for appearance only and does not have to conform to standa...

Страница 16: ...indow sills mantels etc above the fireplace NOTE To avoid heat related finish damage we recommend the use of high temperature paint rated 175 F or higher on the underside of the mantel INSTALLATION PREPARATION The fireplace is shipped with all gas controls and components installed and pre wired Before installing the fireplace follow these steps 1 Remove the shipping carton and retain the front of ...

Страница 17: ...ge 40 Remote Control 15 Initialize the Remote Control System for the First Time Page 41 Finishing 16 Optional Install the Firebox Liners Page 43 17 Traditional Fireplaces Install the Logs Volcanic Stone and Glowing Embers Page 43 18 Contemporary Fireplaces Install Glass Media Page 43 19 Install the Glass Door Page 43 20 Adjust the Air Shutter to Ensure Proper Flame Appearance Page 43 21 Install th...

Страница 18: ...48 43 3 4 1111 18 447 28 1 4 717 C Minimum height of top vent installations E Minimum height of rear vent installations Minimum opening size additional 1 8 per side is recommended NOTE Framing specifications do NOT apply for flexible venting When using flexible venting refer to the kit requirements for framing specifications Vent Framing Top Vent with One 90 Elbow NOTE Dimension D is the required ...

Страница 19: ... of Gas Line Properly size and route the gas supply line from the supply regulator to the area where the appliance is to be installed per requirements outlined in the National Fuel Gas Code NFPA 54 latest edition USA or CAN CGA B149 1 latest edition Canada The gas supply line should not be connected to the appliance until step 12 Connect the Gas Line Page 39 NOTE All fireplaces are factory equippe...

Страница 20: ...enter bracket to the top center of the fireplace Step 3 Top of front fireboard standoff should be flush with top standoffs not shown Step 4 Fireboard standoff can be secured to the cap ture screwholes 4 Determining Vent Setup in the Combination Venting Unit Combination venting units are shipped with rear venting setup nearly ready for install If this is the type of vent you require remove all insu...

Страница 21: ...h framing 1 2 and 5 8 framing depths 2 Secure the fireplace to the side framing members using the unit s nailing flanges one top and bottom on each side of the fireplace front Figure 10 Use 8d nails or the equivalent Figure 10 Nailing Flanges Side framing Unit nailing flange no clearance to combustible framing is required VENT SYSTEM PREPARATION 8 Select a Horizontal or Vertical Vent System 1 With...

Страница 22: ...the unit in the inner fireplace collar The vent restrictor is held in place by friction Vent Restrictor with Horizontal Terminations When horizontally terminating a vent system with a vertical vent run up to 4 ft through an exterior wall no vent restrictor is required If installing more than 4 ft of vertical venting install the restrictor Figure 13 from inside or outside the unit in the inner fire...

Страница 23: ...option to install in tight and confined spaces or where the vent run made up of fixed length pieces develops a joint in a undesirable location or will not build up to the required length The SV4 5LA Telescopic Vent Section has an effective length of from 1 1 2 to 7 38 to 178 mm The SV4 5LA is fitted with a locking inclined channel end identical to a normal vent section component and a plain end wi...

Страница 24: ...3 465 38 75 0 0 0 0 10 10 69 5 75 0 0 0 2 0 2 475 5 39 625 0 1 0 0 10 11 73 5 6 125 1 0 0 2 0 3 480 40 1 1 0 0 10 12 79 5 6 625 0 1 0 2 0 3 492 41 1 0 1 0 10 12 81 6 75 0 0 0 1 1 2 499 5 41 625 0 0 0 1 10 11 91 5 7 625 0 0 2 0 1 3 504 42 1 0 0 1 10 12 93 7 75 0 0 0 0 2 2 511 5 42 625 0 0 0 0 11 11 97 5 8 125 1 0 0 0 2 3 520 5 43 375 0 2 0 1 11 14 103 5 8 625 0 0 0 3 0 3 531 44 25 0 2 2 0 11 15 108...

Страница 25: ...is specified in ANSI Z223 1 In Canada the current CAN CGA B149 1 installation code by major building codes Always consult your local codes for specific requirements A general guide to follow is the gas vent rule Table 6 The following figures and their associated vertical vent tables illustrate the various configurations that are possible for use with these fireplaces Secure Vent pipe is shown in t...

Страница 26: ...bove the ceiling level the firestop spacer must be installed on the bottom side of the ceiling If attic space is above the ceiling the firestop spacer must be installed on the top side of the joist Route the vent sections through the framed opening and secure the firestop spacer with 8d nails or other appropriate fasteners at each corner Remember to maintain 1 26 mm clearance to combustibles frami...

Страница 27: ... necessary Seal the top and both sides of the flashing with waterproof caulking 11 Install the storm collar Install the storm collar supplied with the flashing over the vent flashing joint Figure 21 Loosen the storm collar screw Slide collar down until it meets the top of the flashing Tighten the adjusting screw Apply non combustible caulking or mastic around the circumference of the joint to prov...

Страница 28: ...ARNING Do NOT join separate sections of concentric flexible vent pipe Figure 23 Top Vent Straight Table 16 Rear Vent One 90 Elbow Ceiling firestop spacer SV4 5VF When using Secure Flex use ceiling firestop spacer SF4 5VF 60 ft 18 3 m maximum H Maximum V Minimum feet meters feet meters 2 0 610 1 0 305 4 1 219 2 0 610 6 1 829 3 0 914 8 2 438 4 1 219 Ceiling firestop spacer SV4 5VF When using Secure ...

Страница 29: ...1 H Ceiling firestop spacer SV4 5VF H1 H 8 ft 2 4 m maximum H H1 20 ft 6 1 m maximum V V1 H H1 60 ft 18 3 m maximum Install the U shaped vent restrictor in any vent run with more than 6 ft of vertical rise See Page 22 for more information If 20 ft of H horizontal vent run is needed then 4 ft straight section minimum of V vertical vent will be required This table shows a 1 V to 5 H ratio For every ...

Страница 30: ...t Length on Pages 23 24 for more information Plan the venting so that a joint does not occur in the ceiling or roof joists Allow for elbows Figure 17 Page 23 Maintain the minimum clearances for combustibles Page 25 2 Frame the exterior wall opening Locate the center of the vent outlet on the exterior wall Table 10 Page 18 Cut and or frame an opening 10 1 2 x 12 1 8 267 x 308 mm inside dimensions a...

Страница 31: ...h the adaptor SV4 5RCH provided with the termination to the vent section or telescoping vent section elbow or fireplace collar Figure 25 12 Install the firestop spacer at the exterior wall When using the square termination install SV4 5HF Secure Vent SF4 5HF Secure Flex Firestop Spacer over the opening at the exterior side of the framing long side up with the 3 spacer clearance at the top Figure 2...

Страница 32: ...nstalling the Horizontal Termination NOTE To help minimize water infiltration install the firestop spacer SV4 5HF on the exterior side of the wall The firestop may be caulked with mill base caulk such as 10K81 or high temperature silicone Figure 26 Venting Connection and Exterior Wall Recessing of the Horizontal Termination H1968 Use silicone caulking to seal the top and sides of the termination u...

Страница 33: ...t SF4 5VF Secure Flex firestop spacer must be used any time vent pipe passes through a combustible floor or ceiling SV4 5HF Secure Vent SF4 5HF Secure Flex firestop spacer must be used any time vent pipe passes through a combustible wall WARNING Do not join separate sections of concentric flexible vent together Table 21 Rear Vent No Elbows See Table 20 as an aid in venting component selection for ...

Страница 34: ...cular range of exterior wall thicknesses If 25 ft of H horizontal vent run is needed then 5 ft minimum of V vertical vent will be required This table shows a 1 V to 5 H ratio For every 1 ft of V vertical you are allowed 5 ft of H horizontal run up to a maximum horizontal run of 25 ft 7 62 m When using Secure Flex use Ceiling Firestop Spacer SF4 5VF When using Secure Flex use Wall Firestop Spacer S...

Страница 35: ... wall firestop spacer SF4 5HF Wall firestop spacer SV4 5HF Ceiling firestop spacer SV4 5VF H V H1 H2 Table 27 Top Vent Three 90 Elbows H Maximum V Minimum feet meters feet meters 5 1 524 Elbow only 5 1 524 1 0 305 10 3 048 2 0 610 15 4 572 3 0 914 20 6 096 4 1 219 H H1 25 ft 7 62 m maximum V V1 H H1 60 ft 18 288 m maximum Install the U shaped vent restrictor in any vent run with more than 4 ft of ...

Страница 36: ...r collar to be covered by the flexible pipe and slide the flexible vent over the inner and outer adaptor collars NOTE Outer vent pipe is pulled away to show inner vent pipe details 1 3 4 44 mm flexible vent and adaptor outer collar overlap Adaptor SV4 5RF Attach adaptor to vent collar or Secure Vent sections 1 3 4 44 mm flexible vent and adaptor inner collar overlap Securing screws in three 3 plac...

Страница 37: ...re Flex vent has an longer center tube to improve ease of installation 12 Complete the Field Wiring CAUTION The ground supply lead must be connected to the wire attached to the green ground screw located on the outlet box see wiring diagrams Failure to do so will result in a potential safety hazard The appliance must be electrically grounded in accordance with local codes or in the absence of loca...

Страница 38: ...tlet Some Models MOTOR COMM 120 VAC 120 VAC POWER AUX LIGHTS WHITE RED WHITE BLACK GRAY BLACK MOTOR FAN G COMM SWITCHES Power Vent Models Only Green Draft Call Input BATT V S I White PV Call Proof Out Norm Open Draft SW Dry Contact Only Variable Main Outlet Pilot Outlet Thermocouple To S Terminal on Main Module Main Burner Battery Pack Primary or Backup Dry Contact Switches 7 5VDC 1 Amp Switching ...

Страница 39: ...ear the fireplace NOTE The supplied 15 ft of 6 conductor wire has one end of each conductor connected to the control circuit and the other end of each conductor placed loose inside the bottom compartment 7 After the wiring is complete replace the cover plate WARNING Electronic models of these appliances are equipped with a three prong grounding plug utilized in connecting the electronic components...

Страница 40: ...ply line The orientation of the shutoff valve should face the front Figure 31 illustrates two methods for connecting the gas supply A sediment trap is recommended to prevent moisture and debris in the gas line from damaging the valve Test Factory and Field Connections for Gas Leaks WARNING Never use an open flame to check for leaks Turn on gas supply and test for gas leaks using a gas leak test so...

Страница 41: ... Check the polarity of the batteries and insert them into the battery bay as indicated on the battery cover NOTE See Operation Instructions provided with the remote control Figure 33 Remote Control MODE Zone SET TEMP Zone ROOM TEMP Zone LIGHT Zone FLAME Zone TIME PROG Zone AUX Zone FAN Zone DOWN Button MODE SET Button UP Button MODE SET BACK Cont S M T W T F S AM PM ROOM SET P1 A B P2 P2 AUX P2 Pi...

Страница 42: ...FLAME Zone A Flame Icon and flame setting level number is displayed Program OFF LCD Displays MODE Zone OFF ROOM TEMP Zone Measured temperature is displayed SET TEMP Zone Blank LIGHT Zone LIGHT and light setting level is displayed FAN Zone Blank TIME PROG Zone Current day indicator current time and Program status P1 OFF or P2 OFF is displayed AUX Zone AUX and AUX setting is displayed FLAME Zone Bla...

Страница 43: ...on If the flame remains blue or if the flame is orange with evidence of sooting black tip the air shutter opening may need to be adjusted If the air shutter opening is closed too far sooting may develop Sooting is indicated by black puffs developing at the tips of very long orange flames Sooting results in black deposits forming on the logs fireplace inside surfaces and on exterior surfaces adjace...

Страница 44: ...ce Follow the lighting procedure on the lighting label in the control compartment or Pages 68 69 3 Allow the burner to operate for at least fifteen 15 minutes while observing the flame continuously to ensure that the proper flame appearance is achieved Figure 35 If the following conditions are present adjust accordingly If flame appears weak or sooty adjust the air shutter incrementally to a more ...

Страница 45: ...OTE All models must have a barrier installed prior to operation 1 Open the control compartment door Page 52 2 Hold the barrier in front of the glass door and slide it up into the slots above the glass door and under the hood 3 Slide the barrier bottom down into the slots below the glass door securing it in place 23 Install the Finishing Materials 1 Complete finished interior wall NOTE To install t...

Страница 46: ...iquettesurleboîtier de la télécommande Figure B Choisissez la langue qui est principalement parlée dans la résidence du propriétaire En cas de doute collez l étiquette en anglais 3 Si vous ne trouvez pas les étiquettes veuillez appelerInnovativeHearthProductsouvotredistribu teurInnovativeHearthProductslocalpourrecevoir gratuitement des étiquettes supplémentaires Étiquettes de remplacement n cat H8...

Страница 47: ...rizontal Riser Kit 36 see 750146M Cat No Model Description H6183 SV4 5HF5 Firestop Spacer 5 rigid H6184 SF4 5HF5 Firestop Spacer 5 flex H2246 SV4 5HF 10 Firestop Spacer Horizontal rigid 3 1 1 spacing 10 Pack H2247 SV4 5VF 10 Firestop Spacer Vertical rigid 1 1 1 spacing 10 Pack 96K92 SV4 5SP Support Plate 17M52 SV4 5HGS 1 Termination Guard Square 1 pack see 750109M 17M53 SV4 5HGS 12 Termination Gua...

Страница 48: ...for flex with 24 610 mm compressed flex 77L90 SFKIT36S Square Term for flex with 36 914 mm compressed flex 77L91 SFKIT48S Square Term for flex with 48 1219 mm compressed flex 91L66 SFGC4 6 Gear Clamp 4 5 114 mm for flex 6 pack 91L67 SFGC7 6 Gear Clamp 7 5 190 5 mm for flex 6 pack All compressed flex vents can be expanded up to two times Cat No Model Description 56L74 SFVT30 Vertical Termination fo...

Страница 49: ... installation de cette trousse L installation n est pas adéquate ni complète tant que le bon fonctionnement de l appareil converti n a pas été vérifié selon les instructions du fabricant fournies avec la trousse Le fournisseur de service qualifié ayant réalisé l installation assume les responsabilités liées à la conversion In Canada The conversion shall be carried out in accordance with the requir...

Страница 50: ...by carbon monoxide than others including pregnant women people with heart or lung disease or anemia those under the influence of alcohol and those at high altitudes NOTE Do not place furniture or other combustible materials within 36 of the front of viewing area s NOTE Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing i...

Страница 51: ...gneuse ment pour éliminer la poussière et les traces de graisseoud huile Collezl étiquettesurleboîtierde la télécommande Figure B Choisissez la langue qui est principalement parlée dans la résidence du propriétaire 3 Sivousnetrouvezpaslesétiquettes veuillezappeler Innovative Hearth Products ou votre distribu teur Innovative Hearth Products local pour recevoir gratuitement des étiquettes supplément...

Страница 52: ...om left screw Figure 37 inside the control compartment securing the control compartment door Retain the screw for later reinstallation 2 Position the left side door tab Figure 38 out of the tab groove and align it with the vertical slot Figure 37 Figure 37 Control compartment door slots Figure 38 Control compartment door tabs Vertical slot Screw hole Tab pivot hole Tab groove Door tabs 3 Lift the ...

Страница 53: ...anel carefully position the left side panel in the firebox 4 Carefully position the right side panel in the firebox NOTE Do not force the panels Excessive force may cause breakage If the panels are correctly positioned they will fit snugly in place Contemporary Only Installing the Glass Media 1 Install the glass media in the recessed area between the front and rear floors See Figure 43B on Page 54...

Страница 54: ...ne NOTE It is important to ensure proper log and or media placement per the manual when installing these units Verify pilot flame is not obstructed Ensure media does not fall inside the bracket or through the pilot hole in the floor see Figure 43B See Verifying Appliance Operation on Pages 40 41 Installing the volcanic stone and glowing embers 1 If necessary remove the glass door Pages 61 62 2 Spr...

Страница 55: ...ssary remove the glass door Pages 61 62 Locate the placement tabs Figure 44 2 Bend up the log placement tabs Figure 44 Place glowing embers see Figure 44 Figure 44 Locate the log placement tabs Figure 45 Place log 1 3 Align the notches in the left rear log 1 with the left rear locating tab Figures 44 and 45 4 Position the Rear Log 2 on the left front and right rear log placement locating tabs Figu...

Страница 56: ...n in Figure 48 7 Position the right top log 5 on the pin shown in Figure 48 and as shown in Figure 49 Installing the Scorpio 35 40 45 Series Driftwood Logs continued Figure 48 Place log 4 4 Pin for Log 5 5 6th Log will be placed on the grate Figure 49 Place log 5 8 Position the front ember log 6 on the grate called out in Figure 49 and as shown in Figure 50 6 Figure 50 Place log 6 ...

Страница 57: ...r Pages 61 62 Locate the placement tabs Figure 51 2 Bend up the log placement tabs Figure 51 Place glowing embers see Figure 51 3 Align the notches in the left rear log 1 with the left rear locating tab Figures 51 and 52 Catalog number for the entire set See Page 67 for ordering information 3 4 2 1 Figure 51 Locate the log placement tabs Figure 53 Place log 2 Figure 52 Place log 1 Figure 54 Place ...

Страница 58: ...Hearth Products Scorpio Series Direct Vent Gas Fireplaces 58 Installing the Scorpio 35 Series Charred Oak Logs continued 6 Position the Top Front Left Log 4 shown in Figure 55 on the landing area outlined in Figure 54 Figure 55 Place log 4 4 ...

Страница 59: ...og 5 Top Front Left Log Catalog number for the entire set See Page 67 for ordering information 3 2 5 4 1 1 2 3 Align the notches in the left rear log 1 with the left rear locating tab Figures 56 and 57 4 Position the Rear Log 2 on the left front and right rear placement locating tabs Figures 56 and 58 Figure 56B Locate log placement tabs 45 1 If necessary remove the glass door Pages 61 62 Locate t...

Страница 60: ...h on the bottom of the front right log 3 over the front right locating tab See Figures 56 and 60 6 Position the top front right log 4 as shown in Figure 61 on the landing outlined in Figure 60 4 Pin for Log 5 3 Landing for Log 4 Figure 59 Place log 5 7 Position the Top Front Left Log 5 shown in Figure 59 on the pin outlined in Figure 58 Figure 60 Place log 3 Figure 61 Place log 4 ...

Страница 61: ...talled AVERTISSEMENT Une barrière conçue pour réduire le risque de brûlure par le hublot chaude est fournie avec l appareil et doit être installé WARNING Do not operate appliance with the glass front removed cracked or broken AVERTISSEMENT Ne pas utiliser l appareil si le panneau frontal en verre n est pas en place est craqué ou brisé WARNING Any safety screen or guard removed for servicing the ap...

Страница 62: ...ats evenly as the door draws shut Securely fasten the two 2 latches beneath the firebox floor to the door V flange 4 Install the barrier 5 Close the control compartment door Removing the glass door 1 Open the control compartment door Page 52 NOTE If necessary remove the door and place it in a safe location for later reinstallation 2 Remove the barrier Place the barrier in a safe location for later...

Страница 63: ...enting system components However more frequent periodic inspections and cleanings should be performed by the homeowner NOTE Prior to the first use of the fireplace and each burn season and periodically during the burn season inspect the horizontal termination for debris such as bird nests leaves paper or branches Remove any items from the surfaces of the termination prior to use Also be aware of s...

Страница 64: ... paint brush Reinstalling the embers and logs Carefully follow the placement instructions Pages 54 61 All logs should fit onto the corresponding pins and or log stoppers This will ensure proper flame and safe combustion NOTE Improper positioning of logs can create carbon build up and will alter the performance of the fireplace Replacing the logs If the logs become damaged and need replacement use ...

Страница 65: ...Inspection Qualified Service Technician Perform the appropriate appliance inspection procedure detailed in this manual Replacing Glowing Embers Material Homeowner Qualified Services Technician Remove old ember materials and vacuum the glowing embers rockwool placement area Place new glowing embers as described in this document Maintenance Performed Periodically After the Burning Season Maintenance...

Страница 66: ...dels Cat No Model Description Used on F2224 BLKBP 35 Black Reflective 35 Models F2225 BLKBP 40 Black Reflective 40 Models F2226 BLKBP 45 Black Reflective 45 Models Cat No Model Description Used on F1827 MBLK35B Buff 35 Models F1825 ABLK35V Vintage Red F2188 BLK35OTR H Old Town Red Herringbone F1828 MBLK40B Buff 40 Models F1826 ABLK40V Vintage Red F2189 BLK40OTR H Old Town Red Herringbone F1889 MBL...

Страница 67: ... F2876 CHAROAK35SPO 35 Charred Oak Log Set F2877 CHAROAK40 45SPO 40 and 45 Charred Oak Log Set F2878 DFTWOOD35SPO 35 Driftwood Log Set F2879 DFTWOOD40 45SPO 40 and 45 Driftwood Log Set Charred Oak Logs Driftwood Logs Andiron Kit Traditional Models Cat No Model Description F2227 AKT DV4 Andiron Kit ACCESSORY COMPONENTS continued LOG SETS REQUIRED OPTION ...

Страница 68: ...ch has been under water Copreci Gas Valve Switches Electronic Pilot Assembly 3 Turn off all electric power to the appliance if service is to be performed Note The control may have a battery backup remove batteries if installed 4 Close the main line gas shut off valve 1 STOP Read the safety information above on this label 2 Read the Care and Operation manual including the section on Remote Control ...

Страница 69: ...IDIE NE LAISSEZ JAMAIS UN ENFANT DE TOUCHER LA VITRE L écran pare étincelles fourni avec ce foyer réduit le risque de brûlure en cas de contact accidentel avec la vitre chaude et doit être installé pour la protection Des enfants et Des personnes à risques Interupteurs Option Hi Lo MARCHE ARRÊT Option IPI Mode Intermittent Veilleuse Apprenez Quelques modèles Jaune Bleu Brun fil noir 1 ARRÊTEZ Lisez...

Страница 70: ...Air in the gas line Purge gas line of air call a service technician if required e Unit is not receiving power Replace unit battery backup 3 The main Burner comes on but then goes out a Gas is not reaching the fireplace Check the gas supply and gas shutoff valves b Loose wires to the valve or ignition module Check control compartment for any obviously loose wiring call a service technician if neces...

Страница 71: ...Gasket F2116 1 F2116 1 F2116 1 Porcelain Panel Right J7391 1 J7394 1 J7394 1 Porcelain Panel Left J7392 1 J7395 1 J7395 1 Porcelain Panel Rear J7393 1 J7396 1 J7398 1 Orifice Liquid Propane 19L52 1 99K79 1 39L10 1 Orifice Natural Gas 60J80 1 H3721 1 99K76 1 Orifice Holder H7257 1 H7257 1 H7257 1 Firebox Lamp bulb 25W H8438 1 H8438 1 H8438 1 Firebox Lamp Box H8991 1 H8991 1 H8991 1 Light Harness La...

Страница 72: ...J7956 1 Regulator Liquid Propane J7958 1 J7958 1 J7958 1 Regulator Natural Gas J7934 1 J7934 1 J7934 1 Ecoflow V Wire J7933 1 J7933 1 J7933 1 Ecoflow Control Module J7937 1 J7937 1 J7937 1 Ecoflow Touchscreen Remote control F2689 1 F2689 1 F2689 1 Ecoflow Remote wire harness F2690 1 F2690 1 F2690 1 Ecoflow Lights wire harness F2691 1 F2691 1 F2691 1 Ecoflow Battery backup wire harness F2692 1 F269...

Страница 73: ... fire flood or acts of God b damages caused by abuse negligence misuse or unauthorized alteration or repair of the Product affecting its stability or performance The Product must be subjected to normal use The Product is designed to burn either natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive te...

Страница 74: ... serial number Date fireplace was Installed Type of gas fireplace uses Dealer name IHP reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information Printed in U S A 2016 Innovative Hearth Products P N 900683 00 Rev C 05 2017 1508 Elm Hill Pike ...