Astris.us.com
900741-01D
34
TROUBLESHOOTING
Continued
OBSERVED PROBLEM
POSSIBLE CAUSE
REMEDY
Burner system shuts off. Control
module sounds 2 cycles of 3
beeps.
1. Faulty control module
1. Replace control module.
Burner system shuts off. Control
module sounds 2 cycles of 3
beeps.
1. Remote and control module not com-
municating properly
2. Faulty control module
1. Follow Pairing instructions on
Page 26
to re-pair remote to control module.
2. Replace control module
Burner system shuts off. Control
module sounds 20 beeps.
1. Loss of communication between control
module and remote after 18 minutes.
1. Either the remote is too far from the
burner system or the remote needs new
batteries. The remote should work within
20 feet of the burner system. If it does
not, replace the batteries in the remote
and battery supply box.
Burner system shuts off. Control
module sounds 1 long beep.
1. Control module is too hot
1. Check to see the fi replace size meets the
minimum requirements. Call technical
service.
Burner systems shuts off.
1. The SAFETY temperature setting in the
remote has shut the burner system off.
1. The remote includes a shut off that is
preset at 40C (104F). If the remote is
placed in a location that is at or above
this temperature it will shut the burner
system off. Placing the remote on a
mantel may result in this problem. If it
occurs, relocate the remote to a cooler
location.
Burner system lights or shuts
off without touching the remote.
1. More than one burner system is present
and operating on the same frequency.
1. Follow Pairing instructions on
Page 26
to re-pair remote to control module.