Astris.us.com
900741-01D
28
SPECIFICATIONS
MAGNIFLAME24EP AND
MAGNIFLAME30EP
• Rating (Variable): 31,000/39,000 Btu/Hr
• Type Gas: Propane/LP
• Ignition: Electronic
• Manifold Pressure: 8.0" W.C.
• Inlet Gas Pressure (in. of water):
Max - 14" W.C., Min* - 11" W.C.
*For purpose of input adjustment
MAGNIFLAME24EN AND
MAGNIFLAME30EN
• Rating (Variable): 28,000/38,000 Btu/Hr
• Type Gas: Natural
• Ignition: Electronic
• Manifold Pressure: 4.5" W.C.
• Inlet Gas Pressure (in. of water):
Max - 10.5" W.C., Min* - 5" W.C.
*For purpose of input adjustment
LOGS
• If you remove logs for cleaning, refer to
Installing
Logs, Embers and Volcanic Stone
,
Page 16
, to
properly replace logs.
• Replace log(s) if broken or chipped (dime-sized
or larger).
MAIN BURNER
Periodically inspect all burner fl ame holes with appli-
ance running. All slotted burner fl ame holes should be
open with fl ame present. All round burner fl ame holes
should be open with a small blue fl ame present. Some
burner fl ame holes may become blocked by debris or
rust, with no fl ame present. If so, turn off appliance and
let cool. Remove blockage, blocked burner fl ame holes
will create soot.
Figure 39 - Pilot Inlet Air Hole (Your pilot may
vary from pilot shown)
Pilot Air
Inlet Hole
Pilot Assembly
CLEANING AND MAINTENANCE
Continued
Figure 38 - Injector Holder On Outlet Burner
Tube
Burner Tube
Injector
Holder
Primary Air
Inlet Holes
4. Check injector holder located at end of burner
tube again. Remove any large particles of dust,
dirt, lint or pet hair with a soft cloth or vacuum
cleaner nozzle.
5. Blow air into the primary air holes on the injec-
tor holder.
6. In case any large clumps of dust have now been
pushed into the burner repeat steps 3 and 4.
Clean pilot assembly also. Additional cleaning may
be needed for proper pilot operation based on use/
lack of use. A yellow tip on the pilot fl ame may
indicate dust and dirt in the pilot assembly. There
is a small pilot air inlet hole about from where the
pilot fl ame comes out of pilot assembly
(see
Figure
39
).
With unit off, lightly blow air through air inlet
hole. You may blow through a drinking straw if
compressed air is not available.
WARNING: The injector holders
(air shutters) are not adjustable. Do
not move injector holders from their
original positions.