![Astria Fireplaces MAGNIFLAME24EN Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/astria-fireplaces/magniflame24en/magniflame24en_installation-and-operation-instructions-manual_2990869029.webp)
Astris.us.com
900741-01D
29
WIRING DIAGRAM
Burner 2
Pilot
Thermocouple Ground -
Connector to Chassis
Ground or Valve Body
VCS-ECOMODPVI
(Main Module)
On/Off (Brown)
Optional: Hi/Lo (Blue)
Learn (Black)
Valve
Safety Operator
Optional
Fixed
Outlet
MOTOR
COMM
POWER
SWITCHES
BA
TT
.
V
S
I
V
ariable Main Outlet
Pilot Outlet
Thermocouple - To “S”
Terminal on Main Module
Main Burner
Battery
Pack
(Primary or
Backup)
Dry -
Contact
Switches
“–”
“+”
To Pilot
Igniter
From Pilot
Thermocouple
Regulator
Inlet
Gas Valve
Valve
Step
Motor
Black
Red
Ig
n
it
e
r
-
F
ro
m
“
I”
Terminal on Main Module
Cont.
S M T W T F S
AM
PM
ROOM
SET
P1
A
P1
P2
P2
Pilot
:
ON THERMO OFF
°
u
°
PROGRAM
MODE/SET
Remote
Control
Figure 40 - Wiring Diagram
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors