17

REMOTE CONTROL OPERATION  

Continued

 MODE Zone: Blank
 ROOM TEMP Zone: Blank
 SET TEMP Zone: Blank
 LIGHT Zone: Blank
 FAN Zone: Blank
 TIME/PROG Zone: Day of Week, or Time of Day will Flash
 AUX Zone: Blank
 FLAME Zone: Blank

•  Temperatures may be displayed in degrees F (factory 

default) or degrees C. Press the up and down buttons 

simultaneously to change between degrees F. and C.

MODES OF OPERATION
Operation modes:

•  MANUAL OFF
•  MANUAL ON
The modes may be cycled in the order above by pressing the MODE 

Zone or the MODE/SET Button.

MANUAL OFF MODE

•  Transmits flame OFF command.
•  LCD Displays:

•  MODE Zone: OFF is displaye
•  ROOM TEMP Zone: Measured temperature is displayed
•  SET TEMP Zone: Blank
•  LIGHT Zone: LIGHT and light setting level is displayed
•  FAN Zone: Blank
•  TIME/PROG Zone: Current day indicator and current time 

is displayed

•  AUX Zone: Blank (AUX function is omitted on this control)
•  FLAME Zone: Blank

MANUAL ON MODE:

•  Transmits flame ON command
•  LCD Displays:

•  MODE Zone: ON is displayed
•  ROOM TEMP Zone: Measured temperature is displayed
•  SET TEMP Zone: Blank
•  LIGHT Zone: LIGHT and light setting level is displayed
•  FAN Zone: FAN and fan setting level is unused
•  TIME/PROG Zone: Current day indicator and current time 

is displayed

•  AUX Zone: Blank (AUX function is omitted on this control)
•  FLAME Zone: A&B Flame Icons and flame setting level 

numbers are displayed

THERMOSTAT Mode:

NOTE:

 THE FACTORY DEFAULT SETTING DISABLES THERMOSTAT 

MODE.

• 

Will cycle flame on and off based on room and set temperatures.  

Will transmit ON command if SET TEMP (+SWING) is higher 

than ROOM TEMP and will transmit OFF command if SET TEMP 

(-SWING) is lower than ROOM TEMP.

•  Built-in thermostat will measure room temperature.
•  All programming should be written for deg. F and converted to 

deg. C when selected.

• 

Temperatures may be displayed in degrees F (factory default) or 

degrees C.  Press the UP and DOWN Buttons simultaneously to 

change between degrees F and C.

• 

SET TEMP: While in THERMOSTAT mode, press the UP or DOWN 

Button to change the SET TEMP (45-90 deg. F, 7-32 deg. C); 

the new set temperature will automatically be accepted after 2 

seconds.  The factory default SET TEMP is 45 deg. F.

•  SWING Temperature: This model does not allow for SWING 

temperature adjustment.  This model utilizes thermostatic flame 

modulation that will modulation the main flame based on the 

difference between room temperature and set temperature:
o  Important - factory SWING TEMPERATURE setting is 2 

degrees. The thermostatic flame modulation feature will not 

allow this SWING to be changed.

EXAMPLE:
Set Temperature    

Room Temp. 

Flame Level

 

 

  74F 

 OFF

 

 

  73F 

 Level 

1

Set Temperature (72) 

72F 

 

Level 2 

 

 

  71F 

 Level 

3

 

 

  70F 

 Level 

4

 

 

  69F 

 Level 

5

 

 

  68F 

 Level 

6

 

 

  67F 

 Level 

7

• 

Manual Flame Adjustment while in THERMOSTAT mode: Flame-

A will be the only flame setting that is adjusted automatically.  

Flame-A and Flame-B may be manually adjusted while in thermo-

stat mode.  If Flame-A is manually adjusted while in thermostat 

mode, it will override the automatic flame setting until the flame 

cycles off, then back ON thermostatically; when the flame cycles 

ON again, automatic flame adjustment will resume (Flame-B 

setting will remain as-set by the user).  Automatic flame adjust-

ment will also resume if the operational mode is cycled out of, 

then back into THERMOSTAT mode or if the SET temperature 

is changed.

•  THERMOSTAT OFF LCD Displays:
o  MODE Zone: THERMO and OFF is displayed
o   ROOM TEMP Zone: Measured temperature is displayed
o  SET TEMP Zone: SET TEMP is displayed
o  LIGHT Zone: LIGHT and light setting level is displayed
o  FAN Zone: Blank
o  TIME/PROG Zone: Current day indicator and current time is 

displayed

o  AUX Zone: Blank (AUX function is omitted on this control)
o  FLAME Zone: Blank
•  THERMOSTAT ON LCD Displays:
o  MODE Zone: THERMO and ON are displayed
o   ROOM TEMP Zone: Measured temperature is displayed
o  SET TEMP Zone: SET TEMP is displayed

Содержание F1219

Страница 1: ...r adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ventilation section on page 5 of this manual WARNING If the information in these instructions is not followed...

Страница 2: ...ore trying to assemble operate or service this heater Improper use of this heater can cause serious injury or death from burns fire explo sion electricalshockandcarbonmonoxidepoisoning DANGER Carbon m...

Страница 3: ...replace is designed to be smokeless If logs ever appear to smoke turn off fireplace and call a qualified service person Note During initial operation slight smoking could occur due to log curing and f...

Страница 4: ...ASSACHUSETTS REQUIRE MENTS These appliances are approved for installation in the US state of Mas sachusetts if the following additional requirements are met Un vented Room Heaters shall be installed i...

Страница 5: ...gs exposed to the outside atmosphere have a continuous water vapor retarder with a rating of one perm 6 x 10 11 kg per pa sec m2 or less with openings gasketed or sealed and b weather stripping has be...

Страница 6: ...ortoadjoining room or add ventilation grills between rooms See Ventilation Air From Inside Building B Vent room directly to the outdoors See Ventilation Air From Outdoors C Install a lower Btu Hr fire...

Страница 7: ...moisture See Air for Combustion and Ventilation page 5 CHECK GAS TYPE Use the correct gas type natural or propane LP for your fire place If your gas supply is not correct do not install fireplace Cal...

Страница 8: ...ning 1 12 A 24 2 9 B 21 3 6 C 18 4 4 D 16 5 2 E 14 A B C D E 1 2 3 4 5 Wall Supplied firebox hood must be used at all times Note All vertical measurements are from top of fireplace hood opening to bot...

Страница 9: ...75 01_G 9 17 1 2 29 5 8 29 5 8 16 3 8 7 1 8 1 7 8 8 1 4 44 1 8 1 1 55 1 8 52 47 16 1 2 11 3 4 8 1 4 5 8 INSTALLATION Continued Figure 8 ParisLights43 Series Dimensions Gas Line Access Gas Line Access...

Страница 10: ...e LP supply This fireplace requires anexternalregulator notsupplied Installtheexternal regulatorbetweenthefireplaceandpropane LPsupply WARNING Never connect natural gas fireplace to private non utilit...

Страница 11: ...trap where trapped matter is not likely to freeze A sediment trap traps moisture and contaminants This keeps them from going into fireplace gas controls If sediment trap is not installed or is instal...

Страница 12: ...o gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Figure 13 2 Pressurize supply piping system by either openin...

Страница 13: ...uide screw the rear panel to the fireplace as shown in Figure 16 INSTALLING HOOD 1 Loosen screws at top of face opening and slide hood through screws as shown in Figure 17 2 Tighten screws securing ho...

Страница 14: ...place unscrew 4 corner brackets from the firebox top See Figure 21 2 Remove 2 side walls and then the rear wall Discard rear wall 3 Replace 2 side walls and reinstall the corner brackets Installing Ac...

Страница 15: ...l stay ON when the main burner shuts OFF Figure 26 Gas Module Right Side Figure 27 Gas Module Left Side Remote Control Feature The module has a built in remote control receiver that allows the user to...

Страница 16: ...lied with the unit into the battery compart ment It is recommended that ALKALINE batteries always be used for this product Be sure the batteries are installed with the and ends facing the correct dire...

Страница 17: ...default or degrees C Press the UP and DOWN Buttons simultaneously to change between degrees F and C SET TEMP While in THERMOSTAT mode press the UP or DOWN Button to change the SET TEMP 45 90 deg F 7 3...

Страница 18: ...e A icon and Flame A setting number will flash in the FLAME Zone LIGHT ADJUSTMENT Transmits a light setting command to the control module to adjust the light output level Available settings are 0 off...

Страница 19: ...liance requires 120V electricity for normal operation Control module should be plugged into electrical outlet located underneath firebox bottom Back up battery supply is available for power outages 1...

Страница 20: ...end using compressed air no greater than 30 PSI Your local computer store hardware store or home center may carry compressed air in a can If using compressed air in a can please follow the directions...

Страница 21: ...e running Some burner flame holes may become blocked by debris or rust with no flame present If so turn off fireplace and let cool Remove blockage Blocked burner flame holes will create soot BURNER FL...

Страница 22: ...V MAX 15 AMPS 110V POWER IPI I S MAX 15 AMPS To Rocker Switch To J Box To J Box Pilot Main HI LO DC Motor Drive Light Module Black Black Brown Red Orange Orange To Ground Igniter Sensor PILOT BATTERY...

Страница 23: ...t local propane LP gas company 3 Clean ODS pilot see Cleaning and Main tenance page 20 or replace ODS pilot assembly 4 Replace gas regulator 1 Contact local natural or propane LP gas company 2 Clean b...

Страница 24: ...ng while cooling 1 Burner orifice is clogged or damaged 2 Damaged burner REMEDY 1 Check burner for dirt and debris If found clean burner see Cleaning and Mainte nance page 20 1 Refer to Air for Combus...

Страница 25: ...y 3 Gas leak See Warning statement above 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak See Warning statement above 2 Control valve or gas control...

Страница 26: ...Astria US com 126875 01_G 26 PARTS MODELS PARISLIGHTS43ZEN PARISLIGHTS43ZEP 11 7 4 3 8 8 8 8 14 15 16 17 18 19 20 24 21 5 22 23 6 2 1 13 10 9 12...

Страница 27: ...e 32 1 J6989 Orifice 49 1 7 J6819 Brass Elbow 1 8 J6757 Light Bulb G9 120V 20W 4 9 J5207 Flat Washer 7 10 J4775 Bulkhead Fitting 1 11 J6834 Brass Elbow 2 12 J4714 Flextube Dormont 1 13 J6694 Burner Ga...

Страница 28: ...Astria US com 126875 01_G 28 PARTS MODELS PARISLIGHTS43ZEN PARISLIGHTS43ZEP 1 4 6 2 8 9 7 5 3 5 11 12 13 14 10 7 8...

Страница 29: ...e of non approved parts can result in poor performance and safety hazards KEY NO CATALOG NO DESCRIPTION ParisLights43ZEN F1219 ParisLights43ZEP F1220 QTY 1 J6630 Top Spacer 4 2 J6566 Top Nailing Flang...

Страница 30: ...P 1508 Elm Hill Pike Suite 108 Nashville TN 37210 Visit us at Astria US com SERVICE HINTS When Gas Pressure Is Too Low pilot will not stay lit burners will have delayed ignition fireplace will not pro...

Страница 31: ...ccident riot fire flood or acts of God b damages caused by abuse negligence misuse or unauthorized alteration or repair of the Product affecting its stability or performance The Product must be subjec...

Страница 32: ...name P126875 01 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Co...

Отзывы: