background image

Astria.US.com

126875-01_G

11

INSTALLATION 

Continued

Figure 10 - External Regulator on Propane/LP Supply Tank with 

Vent Pointing Down 

External 

Regulator 

Vent 

Pointing 

Down 

Propane/LP 

Supply Tank 

Installation must include an equipment shutoff valve, union and 

plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge 

hook up. NPT tap must be upstream from fireplace (see Figure 10).

IMPORTANT:

 Install equipment shutoff valve in an accessible loca-

tion. The equipment shutoff valve is for turning on or shutting off 

the gas to the appliance.
Check your building codes for any special requirements for locating 

equipment shutoff valve to fireplaces.
Apply pipe joint sealant lightly to male NPT threads. This will prevent 

excess sealant from going into pipe. Excess sealant in pipe could 

result in clogged fireplace valves. Never use sealant on flare threads.

 WARNING: Use pipe joint sealant that is resistant 

to liquid petroleum (LP) gas. 

We recommend that you install a sediment trap in supply line as 

shown in Figure 11. Locate sediment trap where it is within reach for 

cleaning. Install in piping system between fuel supply and fireplace. 

Locate sediment trap where trapped matter is not likely to freeze. A 

sediment trap traps moisture and contaminants. This keeps them 

from going into fireplace gas controls. If sediment trap is not installed 

or is installed wrong, fireplace may not run properly.

Figure 11 - Gas Connection

* Purchase the optional equipment shutoff valve from your dealer.
** Minimum inlet pressure for purpose of input adjustment.

Sediment Trap

3" Minimum

Cap Pipe Tee

 

 Nipple   Joint

Equipment Shutoff Valve 

With 1/8" NPT Tap*

Natural Gas

From Gas Meter 

(5" W.C.** to 10.5" 

W.C. Pressure)

Propane/LP 

From External 

Regulator 

(11" W.C.** to 14" 

W.C. Pressure)

CONNECTING FIREPLACE TO GAS SUPPLY
Installation Items Needed

•  5/16" hex socket wrench or nut-driver
•  sealant (resistant to propane/LP gas, not provided)
1.  Route flexible gas line (provided by installer) from equipment 

shutoff valve to fireplace. Route flexible gas supply line through 

one of the access holes on side of fireplace.

2.  Attach flexible gas line from gas supply to control valve (see 

Figure 12).

3.  Check all gas connections for leaks. See Checking Gas Connec-

tions, page 12.

Figure 12 - Connecting Incoming Gas Line to Flex Gas Line

Note:

1) Wire connections not shown for clarity

2) * 1/8" NPT Plugged Tapping

MAIN

IN

OUT

PILOT

ADJ

PILOT

Inlet Pressure Tap

Outlet Pressure Tap

Gas Shutoff 

Valve

Flexible Gas Line Do 

NOT Kink

1/2" NPT Incoming 

Gas Line

Set Screw

Содержание F1219

Страница 1: ...r adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ventilation section on page 5 of this manual WARNING If the information in these instructions is not followed...

Страница 2: ...ore trying to assemble operate or service this heater Improper use of this heater can cause serious injury or death from burns fire explo sion electricalshockandcarbonmonoxidepoisoning DANGER Carbon m...

Страница 3: ...replace is designed to be smokeless If logs ever appear to smoke turn off fireplace and call a qualified service person Note During initial operation slight smoking could occur due to log curing and f...

Страница 4: ...ASSACHUSETTS REQUIRE MENTS These appliances are approved for installation in the US state of Mas sachusetts if the following additional requirements are met Un vented Room Heaters shall be installed i...

Страница 5: ...gs exposed to the outside atmosphere have a continuous water vapor retarder with a rating of one perm 6 x 10 11 kg per pa sec m2 or less with openings gasketed or sealed and b weather stripping has be...

Страница 6: ...ortoadjoining room or add ventilation grills between rooms See Ventilation Air From Inside Building B Vent room directly to the outdoors See Ventilation Air From Outdoors C Install a lower Btu Hr fire...

Страница 7: ...moisture See Air for Combustion and Ventilation page 5 CHECK GAS TYPE Use the correct gas type natural or propane LP for your fire place If your gas supply is not correct do not install fireplace Cal...

Страница 8: ...ning 1 12 A 24 2 9 B 21 3 6 C 18 4 4 D 16 5 2 E 14 A B C D E 1 2 3 4 5 Wall Supplied firebox hood must be used at all times Note All vertical measurements are from top of fireplace hood opening to bot...

Страница 9: ...75 01_G 9 17 1 2 29 5 8 29 5 8 16 3 8 7 1 8 1 7 8 8 1 4 44 1 8 1 1 55 1 8 52 47 16 1 2 11 3 4 8 1 4 5 8 INSTALLATION Continued Figure 8 ParisLights43 Series Dimensions Gas Line Access Gas Line Access...

Страница 10: ...e LP supply This fireplace requires anexternalregulator notsupplied Installtheexternal regulatorbetweenthefireplaceandpropane LPsupply WARNING Never connect natural gas fireplace to private non utilit...

Страница 11: ...trap where trapped matter is not likely to freeze A sediment trap traps moisture and contaminants This keeps them from going into fireplace gas controls If sediment trap is not installed or is instal...

Страница 12: ...o gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Figure 13 2 Pressurize supply piping system by either openin...

Страница 13: ...uide screw the rear panel to the fireplace as shown in Figure 16 INSTALLING HOOD 1 Loosen screws at top of face opening and slide hood through screws as shown in Figure 17 2 Tighten screws securing ho...

Страница 14: ...place unscrew 4 corner brackets from the firebox top See Figure 21 2 Remove 2 side walls and then the rear wall Discard rear wall 3 Replace 2 side walls and reinstall the corner brackets Installing Ac...

Страница 15: ...l stay ON when the main burner shuts OFF Figure 26 Gas Module Right Side Figure 27 Gas Module Left Side Remote Control Feature The module has a built in remote control receiver that allows the user to...

Страница 16: ...lied with the unit into the battery compart ment It is recommended that ALKALINE batteries always be used for this product Be sure the batteries are installed with the and ends facing the correct dire...

Страница 17: ...default or degrees C Press the UP and DOWN Buttons simultaneously to change between degrees F and C SET TEMP While in THERMOSTAT mode press the UP or DOWN Button to change the SET TEMP 45 90 deg F 7 3...

Страница 18: ...e A icon and Flame A setting number will flash in the FLAME Zone LIGHT ADJUSTMENT Transmits a light setting command to the control module to adjust the light output level Available settings are 0 off...

Страница 19: ...liance requires 120V electricity for normal operation Control module should be plugged into electrical outlet located underneath firebox bottom Back up battery supply is available for power outages 1...

Страница 20: ...end using compressed air no greater than 30 PSI Your local computer store hardware store or home center may carry compressed air in a can If using compressed air in a can please follow the directions...

Страница 21: ...e running Some burner flame holes may become blocked by debris or rust with no flame present If so turn off fireplace and let cool Remove blockage Blocked burner flame holes will create soot BURNER FL...

Страница 22: ...V MAX 15 AMPS 110V POWER IPI I S MAX 15 AMPS To Rocker Switch To J Box To J Box Pilot Main HI LO DC Motor Drive Light Module Black Black Brown Red Orange Orange To Ground Igniter Sensor PILOT BATTERY...

Страница 23: ...t local propane LP gas company 3 Clean ODS pilot see Cleaning and Main tenance page 20 or replace ODS pilot assembly 4 Replace gas regulator 1 Contact local natural or propane LP gas company 2 Clean b...

Страница 24: ...ng while cooling 1 Burner orifice is clogged or damaged 2 Damaged burner REMEDY 1 Check burner for dirt and debris If found clean burner see Cleaning and Mainte nance page 20 1 Refer to Air for Combus...

Страница 25: ...y 3 Gas leak See Warning statement above 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak See Warning statement above 2 Control valve or gas control...

Страница 26: ...Astria US com 126875 01_G 26 PARTS MODELS PARISLIGHTS43ZEN PARISLIGHTS43ZEP 11 7 4 3 8 8 8 8 14 15 16 17 18 19 20 24 21 5 22 23 6 2 1 13 10 9 12...

Страница 27: ...e 32 1 J6989 Orifice 49 1 7 J6819 Brass Elbow 1 8 J6757 Light Bulb G9 120V 20W 4 9 J5207 Flat Washer 7 10 J4775 Bulkhead Fitting 1 11 J6834 Brass Elbow 2 12 J4714 Flextube Dormont 1 13 J6694 Burner Ga...

Страница 28: ...Astria US com 126875 01_G 28 PARTS MODELS PARISLIGHTS43ZEN PARISLIGHTS43ZEP 1 4 6 2 8 9 7 5 3 5 11 12 13 14 10 7 8...

Страница 29: ...e of non approved parts can result in poor performance and safety hazards KEY NO CATALOG NO DESCRIPTION ParisLights43ZEN F1219 ParisLights43ZEP F1220 QTY 1 J6630 Top Spacer 4 2 J6566 Top Nailing Flang...

Страница 30: ...P 1508 Elm Hill Pike Suite 108 Nashville TN 37210 Visit us at Astria US com SERVICE HINTS When Gas Pressure Is Too Low pilot will not stay lit burners will have delayed ignition fireplace will not pro...

Страница 31: ...ccident riot fire flood or acts of God b damages caused by abuse negligence misuse or unauthorized alteration or repair of the Product affecting its stability or performance The Product must be subjec...

Страница 32: ...name P126875 01 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Co...

Отзывы: