background image

Inst315 

– Viron e-Quilibirum Series Chlorinator Instructions V07_14 

19 

 
For further information on the set up and operation of the 

Viron e-Quilibrium go to Youtube on the following 

links: 
 
Sensor/Probe and RJ12 Connections-    

http://youtu.be/Og89iyocWFw

  

Install Menu Part 1 -  

http://youtu.be/FPWZnp45WyI

  

Setting pH & Chlorine Levels -  

http://youtu.be/jQLrMCDZ9FI

  

Setting the Clock -  

http://youtu.be/LxYU1cZqFIg

  

Setting Timers for Ai Mode - 

 

http://youtu.be/ro1PA1a6zfA

  

Install Menu Part 2 -  

http://youtu.be/AqRg2-cvrfI

  

Statistics Feature -  

http://youtu.be/c0DfntoFTOo

  

Mixing Cell & Dosing Point Installation -  

http://youtu.be/3eIrkH89uBE

 

 

10.0   Important Information about Chlorine Sensing by the eQuilibrium 

 

The Viron eQilibrium uses a ORP sensor to measure and control the chlorine levels in your swimming pool or spa. 
 

  Before installing probes, balance pool water.  Total Alkalinity (TA) must be 80 to 120 ppm, Calcium Hardness 

should be 180 to 250 ppm, and pH must be between 7.2 and 7.6. 

  Dose pool with a small amount of chlorine before starting the eQ.   If no chlorine is sensed the eQ may go to 

fail safe mode and not start up.  Some Chlorine should be present before starting the unit. 

  The Chlorine sensor will take 45 minutes or more to accurately sense the chlorine level in the pool.  Allow 

Pool pump to run for 45 minutes before attempting to calibrate the sensor to the pool water. 
 
Confusion often exists about the difference and relationship between oxidization reduction potential (ORP) and 
chlorine levels measured in parts per million (ppm). 
 
Most pool shops and pool service technicians will focus on chlorine readings in ppm and not the ORP. 
 
ORP is actually a more accurate and important reading than ppm because  it measures the effectiveness of 
chlorine and NOT the level of chlorine in the water.   Relying on ppm can provide a false sense of security and 
may even lead to use of a pool that is dangerous to swim in. 
 
When chlorine is added to the water it reacts to form two separate chemicals, one is hypochlorus acid  (HOCl) and 
the other is hypochloric acid (HCl).   The important chemical to form is HOCl as it is the active or effective form of 
chlorine which oxides and disinfects the contaminants in the water. 
 
The amount of HOCl and HCl formed depends on the pH of the water.   The higher the pH, the less effective HOCl 
is formed and the more ineffective HCl is formed.   Ideally, a pH range of 7.2 to 7.6 forms the most HOCl while 
maintaining soothing water to swim in. 
 
At a pH of say 7.8, only 30% effective HOCI will be formed which means the chlorine is not being effective as 
disinfecting the pool or spa water even though the ppm is 2 or 3 ppm. 
 
However, at a pH of 7.2, a massive 80% effective HOCl will be formed meaning the chlorine is highly effective as 
disinfecting the water even at levels of 1ppm. 
 
ORP remains the best method of measure the sanitiser’s (chlorine’s) effectiveness in the water.   At a reading of 
750mv a virus kill time is as low as one second! 
 
Various other chemicals added to the water can affect the ORP.  For example, most pools will have cyanuric acid 
added to the water which effectively slows down the reaction of the chlorine to make it last longer.   However, the 
slower reaction time of the chlorine lowers the ORP, hence the eQuilibrium will add more chlorine to maintain the 
ORP and keep your pool healthy an safe to swim in. 
 
The important point here is that provided your chlorine sensor (ORP sensor) is checked, cleaned and calibrated 
every 6 months, your Viron eQilibrium will maintain the pH and sanitizer levels for the more comfortable and 
healthiest swimming conditions. 

10.1  Chlorine Reading and Cyanuric Acid 

Содержание Viron eQuilibrium Salt Chlorinator

Страница 1: ...2600 Perth 08 9350 2600 Sydney 02 9853 2100 Townsville 07 4750 3100 sales astralpool com au Brisbane 07 3308 5400 Adelaide 08 8152 7600 www astralpool com au Bolero ND Cleaner INSTALLATION AND OPERATI...

Страница 2: ...for use on Indoor swimming pools UNLESS the pH and Chlorine sensors have been purchased and installed The Viron e Quilibrium can only be purchased through a professional pool business and MUST be inst...

Страница 3: ...utput 12 6 2 Adjusting pH Set Point 13 6 3 Installation of the pH sensor 13 6 4 Installation of the Chlorine Sensor 15 7 0 General Operation Pool Chemistry 16 7 1 Setting the Right Chlorine Output and...

Страница 4: ...me of the chlorine The purpose of the Viron eQuilibrium series chlorinators is to significantly reduce the level of daily and weekly maintenance required to keep you pool and spa sparkling clean and h...

Страница 5: ...ed on a vertical surface wall If mounted on a post a flat sheet 20mm larger than the controller housing must be used a Mount the wall bracket using the screws provided on a secure wall b Glue mixing c...

Страница 6: ...Inst315 Viron e Quilibirum Series Chlorinator Instructions V07_14 6...

Страница 7: ...hose to the outlet of the acid pump on the underside of the controller The remaining end of the PVC hose should be pushed through the cable gland iin the 50mm PVC T fitting so that it passes through t...

Страница 8: ...which your filtration pump pH control and chlorine production will operate Timers are set by entering a start time and a RUN time for how long you want to operate To set timers do the following a Pre...

Страница 9: ...kwash valve on your filter As a guide sand filters should be backwashed for 2 to 3 minutes and then rinsed for 1 minute Press MAINT i Dose will allow you to override the time clock and allow the follo...

Страница 10: ...5 minutes power to the pump outlet will be shut down to prevent your pump running dry f ENABLE LIGHT Your SM series chlorinator has an output to operate a single AstralPool ARC LED light g CELL REVER...

Страница 11: ...utes before adjusting calibrating The most accurate way to calibrate is to put the probe in a calibration solution Calibration solution is available via AstralPool as a spare part When the controller...

Страница 12: ...rine output should only be used when there is no salt in the water In summer the chlorine should be set between 6 and 8 and you should regularly check your chlorine level in your swimming pool to dete...

Страница 13: ...chlorinator cell on return to the pool Once the pH value is set your LCD screen will return to the operating information screen which will cycle through the current status of the chlorinator and the...

Страница 14: ...Inst315 Viron e Quilibirum Series Chlorinator Instructions V07_14 14...

Страница 15: ...e Chlorine Sensor uses Oxidisation Reduction Potential readings to determine the chlorine level in your pool or spa water ORP is the most reliable and safest way to determine the level of the sanitise...

Страница 16: ...lorine ORP should be turned down Refer to Section 10 1 of this operating manual 7 4 pH Level You should keep you pH level between 7 0 and 7 4 for fibreglass pools and 7 2 to 7 8 for other pools 7 5 To...

Страница 17: ...is made of glass please take care for even a hair line crack can cause the sensor to read incorrectly causing malfunction After cleaning the sensors wash with water allow 5 10min to settle and check...

Страница 18: ...peration in Ai Mode When Ai Mode is selected the Viron e Quilibrium will operate in the following manner The pump and electrode cell will start at the first time period After the initial 5 minute prim...

Страница 19: ...iveness of chlorine and NOT the level of chlorine in the water Relying on ppm can provide a false sense of security and may even lead to use of a pool that is dangerous to swim in When chlorine is add...

Страница 20: ...tor will produce more chlorine to reach the set point ORP level than it would otherwise need CyA adds to the TA reading If CyA levels of in excess of 50 ppm are present it is good practice to divide t...

Страница 21: ...th the Chlorine Sensor Ongoing use of Trichlor or Dichlor will continue to raise the level of CyA causing a reduction in the activity of the chlorine and may cause your eQ Chlorinator to continue to r...

Страница 22: ...timer period Increase chlorine output Backwash filter Get Stabiliser between 30 and 60 ppm Increase salt to 4000ppm Increase water temperature or salt level Chlorinator cuts out on overload reduce sal...

Страница 23: ...arts of the Product Parts Warranty Period Control box including PCB s 5 years pro rata 0 payable of invoice total year 1 20 payable of invoice total year 2 40 payable of invoice total year 3 60 payabl...

Страница 24: ...ct was used for a purpose other than one it was intended for c the Product was repaired modified or altered by any person other than AstralPool d the Product has not been installed maintained and or o...

Страница 25: ...Inst315 Viron e Quilibirum Series Chlorinator Instructions V07_14 25...

Страница 26: ...Inst315 Viron e Quilibirum Series Chlorinator Instructions V07_14 26...

Страница 27: ...Inst315 Viron e Quilibirum Series Chlorinator Instructions V07_14 27...

Страница 28: ...Inst315 Viron e Quilibirum Series Chlorinator Instructions V07_14 28...

Отзывы: