background image

Inst315 

– Viron e-Quilibirum Series Chlorinator Instructions V07_14 

 

 The appliance is not intended for use by young children or infirm persons without supervision.   Please ensure 

that young children are supervised to ensure that they do not play with the appliance. 
 

  Controller must be installed according to AS 3000 wiring rules. 

 

  If the supply cord is damaged it must be replaced by AstralPool or its service agent or a similar qualified 

person in order to avoid a hazard. 
 

  This product is NOT suitable for use on Spa Pools UNLESS the OPTIONAL pH sensor has been purchased 

and installed. 
 

  When used on Spa Pool applications, AstralPool strongly recommend the purchase and installation of a 

chlorine sensor in addition to the pH sensor. 
 

  This product is NOT suitable for use on Indoor swimming pools UNLESS the pH and Chlorine sensors have 

been purchased and installed. 
 

  The Viron e-Quilibrium can only be purchased through a professional pool business and MUST be installed 

by that dealer. 
 

  Dose pool with a small amount of chlorine before starting the eQ.   If no chlorine is sensed the eQ may go to 

fail safe mode and not start up.  Some Chlorine should be present before starting the unit. 
 

  Take extreme care when handling the pH adjuster which is either sulphuric acid or hydrochloric acid.  Wear 

gloves, eye protection and breathing protection. 
 

  Before installing probes, balance pool water.  Total Alkalinity (TA) must be 80 to 120 ppm, Calcium Hardness 

should be 180 to 250 ppm, and pH must be between 7.2 and 7.6.  
 

  Cyanic Acid, sometimes referred to as stabiliser or sunscreen will suppress the Chlorine (ORP) reading when 

the Chlorine sensor is connected.   Refer to section on setting chlorine levels if Cyanuric Acid is present in your 
pool. 

 

 

 

 

 

 

 

 

 

 

Содержание Viron eQuilibrium Salt Chlorinator

Страница 1: ...2600 Perth 08 9350 2600 Sydney 02 9853 2100 Townsville 07 4750 3100 sales astralpool com au Brisbane 07 3308 5400 Adelaide 08 8152 7600 www astralpool com au Bolero ND Cleaner INSTALLATION AND OPERATI...

Страница 2: ...for use on Indoor swimming pools UNLESS the pH and Chlorine sensors have been purchased and installed The Viron e Quilibrium can only be purchased through a professional pool business and MUST be inst...

Страница 3: ...utput 12 6 2 Adjusting pH Set Point 13 6 3 Installation of the pH sensor 13 6 4 Installation of the Chlorine Sensor 15 7 0 General Operation Pool Chemistry 16 7 1 Setting the Right Chlorine Output and...

Страница 4: ...me of the chlorine The purpose of the Viron eQuilibrium series chlorinators is to significantly reduce the level of daily and weekly maintenance required to keep you pool and spa sparkling clean and h...

Страница 5: ...ed on a vertical surface wall If mounted on a post a flat sheet 20mm larger than the controller housing must be used a Mount the wall bracket using the screws provided on a secure wall b Glue mixing c...

Страница 6: ...Inst315 Viron e Quilibirum Series Chlorinator Instructions V07_14 6...

Страница 7: ...hose to the outlet of the acid pump on the underside of the controller The remaining end of the PVC hose should be pushed through the cable gland iin the 50mm PVC T fitting so that it passes through t...

Страница 8: ...which your filtration pump pH control and chlorine production will operate Timers are set by entering a start time and a RUN time for how long you want to operate To set timers do the following a Pre...

Страница 9: ...kwash valve on your filter As a guide sand filters should be backwashed for 2 to 3 minutes and then rinsed for 1 minute Press MAINT i Dose will allow you to override the time clock and allow the follo...

Страница 10: ...5 minutes power to the pump outlet will be shut down to prevent your pump running dry f ENABLE LIGHT Your SM series chlorinator has an output to operate a single AstralPool ARC LED light g CELL REVER...

Страница 11: ...utes before adjusting calibrating The most accurate way to calibrate is to put the probe in a calibration solution Calibration solution is available via AstralPool as a spare part When the controller...

Страница 12: ...rine output should only be used when there is no salt in the water In summer the chlorine should be set between 6 and 8 and you should regularly check your chlorine level in your swimming pool to dete...

Страница 13: ...chlorinator cell on return to the pool Once the pH value is set your LCD screen will return to the operating information screen which will cycle through the current status of the chlorinator and the...

Страница 14: ...Inst315 Viron e Quilibirum Series Chlorinator Instructions V07_14 14...

Страница 15: ...e Chlorine Sensor uses Oxidisation Reduction Potential readings to determine the chlorine level in your pool or spa water ORP is the most reliable and safest way to determine the level of the sanitise...

Страница 16: ...lorine ORP should be turned down Refer to Section 10 1 of this operating manual 7 4 pH Level You should keep you pH level between 7 0 and 7 4 for fibreglass pools and 7 2 to 7 8 for other pools 7 5 To...

Страница 17: ...is made of glass please take care for even a hair line crack can cause the sensor to read incorrectly causing malfunction After cleaning the sensors wash with water allow 5 10min to settle and check...

Страница 18: ...peration in Ai Mode When Ai Mode is selected the Viron e Quilibrium will operate in the following manner The pump and electrode cell will start at the first time period After the initial 5 minute prim...

Страница 19: ...iveness of chlorine and NOT the level of chlorine in the water Relying on ppm can provide a false sense of security and may even lead to use of a pool that is dangerous to swim in When chlorine is add...

Страница 20: ...tor will produce more chlorine to reach the set point ORP level than it would otherwise need CyA adds to the TA reading If CyA levels of in excess of 50 ppm are present it is good practice to divide t...

Страница 21: ...th the Chlorine Sensor Ongoing use of Trichlor or Dichlor will continue to raise the level of CyA causing a reduction in the activity of the chlorine and may cause your eQ Chlorinator to continue to r...

Страница 22: ...timer period Increase chlorine output Backwash filter Get Stabiliser between 30 and 60 ppm Increase salt to 4000ppm Increase water temperature or salt level Chlorinator cuts out on overload reduce sal...

Страница 23: ...arts of the Product Parts Warranty Period Control box including PCB s 5 years pro rata 0 payable of invoice total year 1 20 payable of invoice total year 2 40 payable of invoice total year 3 60 payabl...

Страница 24: ...ct was used for a purpose other than one it was intended for c the Product was repaired modified or altered by any person other than AstralPool d the Product has not been installed maintained and or o...

Страница 25: ...Inst315 Viron e Quilibirum Series Chlorinator Instructions V07_14 25...

Страница 26: ...Inst315 Viron e Quilibirum Series Chlorinator Instructions V07_14 26...

Страница 27: ...Inst315 Viron e Quilibirum Series Chlorinator Instructions V07_14 27...

Страница 28: ...Inst315 Viron e Quilibirum Series Chlorinator Instructions V07_14 28...

Отзывы: