10 

ii. 

INSTALL

 allows the unit to be set up for your pool or spa.  This should only be selected in the initial start 

up of your Chlorinator.    Select INSTALL and the following will occur: 

a. 

TIMER ENABLED

 

– this function will turn your timer on or off.  If the chlorinator is not connected to an 

external timer clock or Genus Remote Control system Press 

ACCEPT

.   If an external timeclock is used to 

operate the chlorinator and filter pump then change to disabled. 

b. 

FAST COMMS 

– set standard to YES, this option will only need to be changed if using a older version 

Hurlcon controller (no touchscreen) 

c. 

VARIABLE SPEED PUMP

 

– select YES if you have an AstralPool 3 speed pump. This will allow you to 

program the speed of the pump as part of the timer setting in the chlorinator. 

d. 

FLUSH AFTER TIMER 

– select YES and your pump will come on momentarily after the timers have 

finished to flush any residual chemicals from the mixing cell. 

e. 

PUMP FLOW CHECK 

– If active this function will monitor the flow sensor inside the chlorinator cell. If the 

presence of water flow is not detected for over 5 minutes, power to the pump outlet will be shut down to 
prevent your pump running dry. 

f. 

ENABLE LIGHT

 

– Your SM series chlorinator has an output to operate a single AstralPool ARC LED light.  

g. 

CELL REVERSAL PERIOD

 

– Standard setting is 4 hours. This should not be changed without consulting 

with your local AstralPool dealer or service department. 

h. 

REVERSE CELL? 

– This feature can be used to perform a manual reverse of your chlorinator cell – 

designed for use by your pool technician only. 

i. 

SET POOL WATER VOLUME

, select 

YES

 and then use up or down arrows to change the volume of your 

pool.  Press 

ACCEPT

 

j. 

SET SPA WATER VOLUME

, select 

YES 

if your have a SPA attached to your pool and then set volume.  

Press 

ACCEPT

 

k.  RESET SYSTEM?

 

– 

SELECT NO 

(This option will revert your chlorinator back to factory settings. It 

should only be used if your SM series chlorinator enters an error that cannot be cleared)

 

 

Cycle through 

POOL MODE

 button to select

 Auto

Manually ON

 or 

Manually OFF

AUTO

 will allow the unit to operate your filter pump, chlorine production and pH adjustment on the timer 

periods you have selected.  If you have not changed the timer periods, the default timer turns the filter pump 
and unit on at 08:00 hours for a period of 4 hours and then again at 16:00 hours for a further period of 4 hours.  
This is the default setting from the factory. 

 

Содержание Viron eQuilibrium Salt Chlorinator

Страница 1: ...2600 Perth 08 9350 2600 Sydney 02 9853 2100 Townsville 07 4750 3100 sales astralpool com au Brisbane 07 3308 5400 Adelaide 08 8152 7600 www astralpool com au Bolero ND Cleaner INSTALLATION AND OPERATI...

Страница 2: ...for use on Indoor swimming pools UNLESS the pH and Chlorine sensors have been purchased and installed The Viron e Quilibrium can only be purchased through a professional pool business and MUST be inst...

Страница 3: ...utput 12 6 2 Adjusting pH Set Point 13 6 3 Installation of the pH sensor 13 6 4 Installation of the Chlorine Sensor 15 7 0 General Operation Pool Chemistry 16 7 1 Setting the Right Chlorine Output and...

Страница 4: ...me of the chlorine The purpose of the Viron eQuilibrium series chlorinators is to significantly reduce the level of daily and weekly maintenance required to keep you pool and spa sparkling clean and h...

Страница 5: ...ed on a vertical surface wall If mounted on a post a flat sheet 20mm larger than the controller housing must be used a Mount the wall bracket using the screws provided on a secure wall b Glue mixing c...

Страница 6: ...Inst315 Viron e Quilibirum Series Chlorinator Instructions V07_14 6...

Страница 7: ...hose to the outlet of the acid pump on the underside of the controller The remaining end of the PVC hose should be pushed through the cable gland iin the 50mm PVC T fitting so that it passes through t...

Страница 8: ...which your filtration pump pH control and chlorine production will operate Timers are set by entering a start time and a RUN time for how long you want to operate To set timers do the following a Pre...

Страница 9: ...kwash valve on your filter As a guide sand filters should be backwashed for 2 to 3 minutes and then rinsed for 1 minute Press MAINT i Dose will allow you to override the time clock and allow the follo...

Страница 10: ...5 minutes power to the pump outlet will be shut down to prevent your pump running dry f ENABLE LIGHT Your SM series chlorinator has an output to operate a single AstralPool ARC LED light g CELL REVER...

Страница 11: ...utes before adjusting calibrating The most accurate way to calibrate is to put the probe in a calibration solution Calibration solution is available via AstralPool as a spare part When the controller...

Страница 12: ...rine output should only be used when there is no salt in the water In summer the chlorine should be set between 6 and 8 and you should regularly check your chlorine level in your swimming pool to dete...

Страница 13: ...chlorinator cell on return to the pool Once the pH value is set your LCD screen will return to the operating information screen which will cycle through the current status of the chlorinator and the...

Страница 14: ...Inst315 Viron e Quilibirum Series Chlorinator Instructions V07_14 14...

Страница 15: ...e Chlorine Sensor uses Oxidisation Reduction Potential readings to determine the chlorine level in your pool or spa water ORP is the most reliable and safest way to determine the level of the sanitise...

Страница 16: ...lorine ORP should be turned down Refer to Section 10 1 of this operating manual 7 4 pH Level You should keep you pH level between 7 0 and 7 4 for fibreglass pools and 7 2 to 7 8 for other pools 7 5 To...

Страница 17: ...is made of glass please take care for even a hair line crack can cause the sensor to read incorrectly causing malfunction After cleaning the sensors wash with water allow 5 10min to settle and check...

Страница 18: ...peration in Ai Mode When Ai Mode is selected the Viron e Quilibrium will operate in the following manner The pump and electrode cell will start at the first time period After the initial 5 minute prim...

Страница 19: ...iveness of chlorine and NOT the level of chlorine in the water Relying on ppm can provide a false sense of security and may even lead to use of a pool that is dangerous to swim in When chlorine is add...

Страница 20: ...tor will produce more chlorine to reach the set point ORP level than it would otherwise need CyA adds to the TA reading If CyA levels of in excess of 50 ppm are present it is good practice to divide t...

Страница 21: ...th the Chlorine Sensor Ongoing use of Trichlor or Dichlor will continue to raise the level of CyA causing a reduction in the activity of the chlorine and may cause your eQ Chlorinator to continue to r...

Страница 22: ...timer period Increase chlorine output Backwash filter Get Stabiliser between 30 and 60 ppm Increase salt to 4000ppm Increase water temperature or salt level Chlorinator cuts out on overload reduce sal...

Страница 23: ...arts of the Product Parts Warranty Period Control box including PCB s 5 years pro rata 0 payable of invoice total year 1 20 payable of invoice total year 2 40 payable of invoice total year 3 60 payabl...

Страница 24: ...ct was used for a purpose other than one it was intended for c the Product was repaired modified or altered by any person other than AstralPool d the Product has not been installed maintained and or o...

Страница 25: ...Inst315 Viron e Quilibirum Series Chlorinator Instructions V07_14 25...

Страница 26: ...Inst315 Viron e Quilibirum Series Chlorinator Instructions V07_14 26...

Страница 27: ...Inst315 Viron e Quilibirum Series Chlorinator Instructions V07_14 27...

Страница 28: ...Inst315 Viron e Quilibirum Series Chlorinator Instructions V07_14 28...

Отзывы: