6.1___LIST OF VARIABLES
6.1.1___ PRG1 menu
Enter the programming menu (
See Page 16
) and go to the
PRG1
function.
The variables viewed are the following:
VARIABLES
PERMISSIBLE LIMITS
DEFAULT VALUES
COMMENTS
PH SETTINGS
SET
0 to 14,00
pH 7.20
SET POINT pH
ALL
0 to SET
pH 6.50
pH minimum alarm
ALH
SET to 14.00
pH 7.90
pH maximum alarm
REL
ACID/ALKALINE
ACID
Type of control
HIS
0,00…1,40
0,00 pH
PH hysteresis
CHLORINE SETTINGS
SET
0…5,00
0.60 ppm
Chlorine SET POINT
ALL
0…SET
0.30 ppm
Chlorine minimum alarm
ALH
SET…5,00
1.50 ppm
Chlorine maximum alarm
REL
LO
LO
Type of control
HIS
0,00…0,50
0.00 ppm
Chlorine hysteresis
CPH
ON / OFF
OFF
Enabling of correction of
chlorine measurement in
relation to pH.
ENABLING
EN
S-/-C/SC/--
SC
Enables the Cal and Set
keys
By setting these variables it is possible to achieve ON / OFF control of the metering pumps.
Example:
The graphs illustrate adjustment of the measurement Set Point with a hysteresis value other than
nought.
SET POINT pH = 7,20 pH (SET)
Hysteresis = 0,10 pH (HIS)
SET POINT CL = 0.90 ppm (SET)
Hysteresis = 0.10 ppm (HIS)
17
Содержание PC95
Страница 1: ...Manual de Instrucciones PC95 pH cloro temperatura Cod 136317 Manual 0000136317 Versi n r 2 0...
Страница 22: ...Set Point 1 00 ppm HIS 0 10 ppm la regulaci n es la l nea punteada Ton 10 Seg Tof 10 Seg BND 0 30 ppm 22...
Страница 30: ...Instruction Manual PC95 pH chlorine temperature Cod 0000136317 Manual 0000136317 Version r 2 0...
Страница 59: ...Manuale Istruzioni PC95 cod 136317 pH cloro temperatura Manuale 0000136317 Versione r 2 0...