Astralpool ALASKA Series Скачать руководство пользователя страница 8

 

ALASKA / SIBERIA / BERING SERIES · Cooler EF

 

AIR/WATER 

 WATER/WATER 

 

© FLUIDRA 2019 ALL RIGHTS RESERVED. PROPRIETARY DOCUMENT. 

Pag: 8

 

ENGLISH 

 

2.4

 

HAZARDS 

This section identifies the residual risks identified through a risk assessment. 

To  reduce  health  hazards  and  avoid  dangerous  situations,  pay  attention  to  the  safety 
instructions listed below: 

 

DANGER OF INJURY BY LIQUID ACCUMULATIONS: 

Danger of slippage by liquid accumulation. 

 

Collect liquids accumulation with the proper means. 

 

Wear non-slip safety footwear. 
Place warning and signaling signs in the area where liquid 
accumulation may occur. 

 

DANGER OF INJURY OR DEATH BY ELECTRICAL SHOCK: 

In the event of direct contact with live parts, there is a risk of death from 
electric shock. Damage to the insulation or damage to various components 
can lead to death. 

 

Only qualified people may work on the electrical installation. 

 

If you notice any damage to the insulation, disconnect power 
supply and proceed to repair any damage. 

 

Before starting any work on the electrical installation, follow the 
following rules:  

 

Remove power supply. 

 

Safeguard against reconnection. 

 

Check coltage absence. 

 

Grounding and short-circuiting 
Protect the work area. 

 

DANGER OF INJURY BY MOVING PARTS: FANS 

Rotating parts of the fans can cause serious injuries. 

 

Do not put your hands into the fan rotor or maintenance it 
during operation. 

 

Do not open the machine’s panels during operation.

 

 

Make sure that the fan rotor is not accessible during 
operation. 

 

Pay attention to the fan stop interval before opening the 

machine’s panels.

 

 

Before opening the fan, check that it is stationary. 

 

DANGER OF INJURY BY SHARP EDEGES AND SHARP CORNERS: 

Danger of injury with sharp edges and sharp corners. 
Sharp edges and sharp corners on components housing parts can cause 
cuts on the skin. 

 

When working in the vicinity of sharp edges or sharp corners, 
proceed with coution. 

 

Wear protective gloves. 

Содержание ALASKA Series

Страница 1: ...BERING Modbus 66306 66307 66308 66309 66311 66312 ALASKA SIBERIA BERING SERIES HEAT PUMP TECHNICAL MANUAL START UP AND OPERATION MANUAL TÉCNICO ARRANQUE Y FUNCIONAMENTO MANUEL TECHNIQUE MISE EN ROUTE ET FONCTIONNEMENT TECHNISCHES HANDBUCH INBETRIEBNAHME UND BETRIEBSWEISE MANUALE TECNICO AVVIAMENTO E FUNZIONAMENTO MANUAL TÉCNICO ARRANQUE E FUNCIONAMENTO EDITION 2 15 05 2019 ALASKA SIBERIA BERING ...

Страница 2: ... FLUIDRA 2019 ALL RIGHTS RESERVED PROPRIETARY DOCUMENT Pag 2 ...

Страница 3: ...SAFETY INSTRUCTIONS 13 1 2 REQUIREMENTS AND PREVIOUS OPERATIONS 13 1 3 OPERATING CONDITIONS 14 5 4 CONDENSATION DRAIN 17 6 REGULATOR 18 6 1 MAIN FUNCTIONS 18 6 2 MAIN TECHNICAL CHARACTERISTICS 19 6 3 PARAMETER SETTINGS 19 6 4 STARTING BASIC OPERATION 23 6 4 1 OPERATING MODE 23 6 4 2 HEAT MODE 23 6 4 3 COOL MODE CHILLER MODELS 24 6 4 4 AUTO MODE CHILLER MODELS 25 6 4 5 PROCESO DE DESESCARCHE 25 6 4...

Страница 4: ...ON 28 6 5 9 LOW TEMPERATURE LIMITS THE COMPRESSOR RUNNING 29 6 5 10 ANTIFREEZE PROTECTION IN WINTER 29 6 5 11 SENSOR FAULT PROTECTION 29 6 6 TROUBLESHOOTING GUIDE SYSTEM FAULTS AND LIST OF ERROR CODES 30 6 7 CONTROL LCD 32 6 8 DISPLAY functions 36 7 GENERAL PRECAUTIONS 38 8 HECKING THE PACKAGING 39 9 ELECTRICAL CONNECTIONS 39 10 HYDRAULIC CONNECTIONS 41 11 START UP PROCEDURE 41 12 PREVENTIVE MAINT...

Страница 5: ...or correct installation and proper performance The warning symbol indicates important information to bear in mind to prevent risk of injuries and or damage for the user and or the equipment The forbidden symbol indicates an operation procedure that is forbidden and will cancel the warranty WE RECOMMEND THAT YOU MAKE A NOTE OF THE FOLLOWING INSTALLER DATE TELEPHONE MODEL SERIAL NO DISTRIBUTOR S STA...

Страница 6: ...s Además el titular debe capacitar e informar sobre peligros al personal a intervalos regulares El titular debe poner a disposición del personal el equipo de protección adecuado El titular también es responsable de que el equipo esté en un perfecto estado técnico Por ello será de aplicación lo siguiente El titular debe garantizar que se cumplan los intervalos de mantenimiento descritos en este man...

Страница 7: ...They are tight work clothes of low tear resistance with narrow sleeves and without protruding elements It is intended for not being trapped by moving parts of the machine Do not wear rings necklaces or other adornment objects SAFETY SHOES Safety shoes protect against heavy falling parts and avoid sliding on slippery surfaces GLASSES AND EARPLUGS They serve to protect the eyes from projections of s...

Страница 8: ...ectrical installation If you notice any damage to the insulation disconnect power supply and proceed to repair any damage Before starting any work on the electrical installation follow the following rules Remove power supply Safeguard against reconnection Check coltage absence Grounding and short circuiting Protect the work area DANGER OF INJURY BY MOVING PARTS FANS Rotating parts of the fans can ...

Страница 9: ...eeze burns When working in the vicinity of cold surfaces wear protection gear clothing and safety gloves DANGER OF INJURY BY PRESSURIZED GASES Pressurized components of the equipment can leak fluids under high pressure if they are handled incorrectly or in case of defect and cause serious injuries Before working with the pressurized elements remove the pressure DANGER OF INJURY BY FIRE If the fire...

Страница 10: ...cooling the pool cup cold water basins etc If the unit package is damaged upon delivery or the delivery itself is incomplete make a note on the carrier s bill and immediately place a claim to the carrier company IS VERY IMPORTANT TO KEEP THE PACKAGED EQUIPMENT UPRIGHT THE PACKAGING HAS BEEN SPECIFICALLY DESIGNED FOR THIS ALWAYS MAINTAIN IT IN A VERTICAL POSITION IF THE UNIT IS DAMAGED OR THE DELIV...

Страница 11: ... with lacquered aluminium fins that are specially designed for corrosive and coastline environments Fan s Axial ALASKA Centrífugal SIBERIA Scroll Compressor G2 titanium water condensers Guaranteed corrosion resistance Coolant gas R 407 C High and Low pressure switches HP LP Expansion by thermostatic mixing valve with external balancer By flow dehydrator filter Hydraulic circuit with waterflow swit...

Страница 12: ...l data of the machine series TABLE 4 MAXIMAL ELECTRICAL DATA ALASKA pág 49 TABLE 5 MAXIMAL ELECTRICAL DATA SIBERIA pág 49 TABLE 6 MAXIMAL ELECTRICAL DATA BERING pág 49 4 4 ELECTRICAL DIAGRAMS To look up electrical diagrams of the different equipment consult IMAGE 1 ELECTRICAL SCHEME ALASKA SIBERIA BERING pág 50 IMAGE 2 BORNES ALASKA SIBERIA BERING pág 51 IMAGE 3 POWER ALASKA SIBERIA BERING pág 52 ...

Страница 13: ...a safe way and understanding the hazards involved Refer to paragraph Error No se encuentra el origen de la referencia pág Error Marcador no definido 1 2 REQUIREMENTS AND PREVIOUS OPERATIONS Todos los modelos Check the place where the equipment is to be located is strong enough to support the weight of this To improve the distribution of weights the unit will be placed on a bench according to the d...

Страница 14: ...ke duct to be able to check its condition and proceed to clean any dirt that may be trapped in the air inlet of the unit Leave at least 1 meter of unused space around the equipment to facilitate personnel access and maintenance operations 1 3 OPERATING CONDITIONS Water physical and chemical parameters must be in between PH 7 2 a 7 8 Residual chlorine 1 a 2 ppm Alkalinity 80 125 ppm Total dissolved...

Страница 15: ...ata provided in the data sheet may vary if these placement recommendations do not occur It is extremely important that the minimum water flow indicated in the technical sheet is guaranteed If this flow is reduced the compressor dew point is higher and the energy consumption is higher Example of installation of ALASKA with Axial fan for outdoor installation only V1 V2 V3 By pass valves Required for...

Страница 16: ...etwork so that the air collected by the machine to operate the refrigeration circuit never return to the machine and must be expelled to the street The machine must be located exclusively inside In this example of installation it can be seen that the technical room is perfectly ventilated through a grid of sufficient size to guarantee the correct flow of air through the evaporator And that the dri...

Страница 17: ... Pa and if this value is not respected the heat pump can be damaged For greater load losses available consult Fluidra Comercial 5 4 CONDENSATION DRAIN The machine will naturally generate condensation water This water will be gathered inside the machine and will come out through a condensation drain located on the frame of the equipment The installation must have a drain to evacuate such condensati...

Страница 18: ...ts limits A11 A12 A13 or A14 DIFFERENT PERIOD OF OPERATION The regulator has two operating modes Heating and Schedule programming In the Cooling mode the machine will operate until the water temperature reaches the setpoint temperature set by the user In the Schedule programming mode as many as three machine operating periods can be scheduled See STARTING BASIC OPERATION PHASE MISSING PROTECTION A...

Страница 19: ...470K 6 3 PARAMETER SETTINGS Press S for 3 seconds to enter the parameter settings menu You can change the following parameters F11 F50 F54 F58 F61 F62 F85 press to select the parameter you want to change Use to select the code press S to show the parameter setting and use to change it Press S again to save the changes and return to the parameter settings menu Press S you can see the value of the p...

Страница 20: ...temperature of Low speed operation 10 30 10 C 1 Temperature differential 1 C 2 Always working at low speed 10ºC F28 OPERATING MODES ENABLED 35 100 44 C Temperature differential 1 C F29 Defrost start temperature 0 1 2 3 2 0 Automatic mode C H 1 Heat mode Heat 2 Cool mode Cool 3 Choose the mode M Desescarche Remote control F31 Defrost end temperature 10 0 3 C F32 Defrost start time 5 35 15 C F33 Max...

Страница 21: ...ctrical heater 10 20 12 C If electrical heater is available F60 Over high temperature difference between water inlet and water outlet failure 0 20 3 C Alarm and probe calibration F61 Water inlet Temp sensor adjustment 20 20 0 C Adjust the temperature sensor calíbrate F62 Water outlet Temp sensor adjustment 20 20 0 C Adjust the temperature sensor calíbrate F63 1 Calibration temperature defrost prob...

Страница 22: ...me and show the alarm code A99 OFF means no probation time F87 Reset tiempo en marcha acumulado no yes no System settings F88 Reset factory parameters no yes no Reset of all parameters Reset if the card software is updated F90 Show the card model F91 Show the card software version F92 Show the model of the display Test F93 Display the main board software version number F96 Time setting F97 Reserve...

Страница 23: ...mperature Differential temperature In the Heat mode the machine starts heating the water when the probe temperature is lower than the Temperature setpoint Temperature differential and it stops heating when the temperature is higher than the Setpoint temperature Differential temperature In the Auto mode the machine starts cooling when the probe temperature is higher than the Temperature setpoint Au...

Страница 24: ...ff 5S COMP2 off 20s FAN off F42 water pump off HEATING OFF F37 0 10S water pump on 15S FAN on COMP1 on COMP2 on HEATING ON F37 1 0S 4 way valve on 0S COMP1 off 5S COMP2 off 20s FAN off water pump off HEATING OFF F37 1 50s 4 way valve off F21 1 3min F21 30s F42 10S water pump on 15S FAN on COMP1 on COMP2 on COOLING ON F37 1 0S COMP1 off 5S COMP2 off 20s FAN off water pump off COOLING OFF F37 1 10S ...

Страница 25: ...In other words the defrosting calculagraph begins to count when the machine evaporator temperature is lower than defrost start temperature and turns on the defrosting when the value of time reaches defrost start time The calculagraph will be cleared if the evaporator temperature is higher than defrost start temperature when counting and it begins to count again when the evaporator temperature is l...

Страница 26: ...ime they will have a delay between them Remark when pipe1 sensor faults pipe2 temperature sensor will be used when pipe1 and pipe2 sensor fault The system will check external air temperature if external air temperature F35 and the machine run time Defrost start time the machine will defrost if defrost time Max defrost time then defrost will stop 6 4 6 WATER PUMP CONTROL The controller can choose w...

Страница 27: ...ay OFF If the unit is stopped The unit stops 6 5 PROTECTION SYSTEMS 6 5 1 COMPRESSOR DELAY PROTECTION The compressor delay time is adjustable F21 and set to 5 minutes by default The regulator uses this time setting to prevent continuous ON OFF cycles When the compressor has been running and then stops the next time it is started up the regulator will check that the period of time has passed before...

Страница 28: ...ck the low pressure signal The controller checks during 5 seconds the status of the low pressure switch and it will take another 5 seconds to act If it is open the machine will stop If at any time the status of the low pressure switch is closed the machine will run automatically But if within an hour we have 3 alarms of this protection the system will be blocked in alarm status and display error c...

Страница 29: ...s below 4ºC and the air temperature is below 3ºC and the machine is OFF or in stand by mode the machine will activate the water pump to avoid having the water in the pipes iced piping broken 6 5 11 SENSOR FAULT PROTECTION Pipe 1 Exhaust 1 Pipe 2 Exhaust 2 Sensors work independently in each circuit and display different error codes to distinguish between different systems Water inlet temperature se...

Страница 30: ...r short circuit Check or change the sensor Exhaust sensor 1 failure A24 The sensor is open or short circuit Check or change the sensor Exhaust sensor 2 failure A25 The sensor is open or short circuit Check or change the sensor Fault probe aspiration circuit 1 A26 The sensor is open or short circuit Check or change the sensor Fault probe aspiration circuit 2 A27 The sensor is open or short circuit ...

Страница 31: ... or lack of connection Check connections of power input wire Phase loss A92 Some phase has no voltage Check electrical connections Compressor 1 overcurrent protection A93 Compressor overcurrent Check the system Compressor 2 overcurrent protection A94 Compressor overcurrent Check the system The time limit running failure A99 Running time exceed Check the time limit Signal failure The cable between ...

Страница 32: ...S RESERVED PROPRIETARY DOCUMENT Pag 32 ENGLISH 6 7 CONTROL LCD Note The error codes flash when displayed on the LCD screen Icono Descripción Observación The machine is off The machine is setting and standby The machine is running The machine is doing defrost Frost protection HEAT MODE ...

Страница 33: ... TIME Compressor 1 Compressor 2 4 way valve activated High Fan Speed Normal Fan Speed Electric resistance Optional Clean Fan Water pump communication is abnormally RS485 Alarm Locked keyboard Phase protection 1 Compressor current too high 2 Compressor current too high No water litter water in water system System 1 high pressure protection System 1 low pressure protection ...

Страница 34: ...ough Water pressure is too low Limit of the operation time Fault in the water inlet probe Water inlet temp sensor failure Water outlet temp sensor failure Cool1 sensor1 failure Cool2 sensor1 failure 1 Compressor exhaust probe failure 1 2 Compressor exhaust probe failure 2 Failure in the outdoor air temperature probe 1 Compressor exhaust too high 2 Compressor exhaust too high Time setting Temperatu...

Страница 35: ...ES Cooler EF AIR WATER WATER WATER FLUIDRA 2019 ALL RIGHTS RESERVED PROPRIETARY DOCUMENT Pag 35 ENGLISH 1 WATER IN TEMPERATURE 2 WATER OUT TEMPERATURE 3 SYSTEM MODE 4 MACHINE OUTPUT STATUS 5 ERROR CODES 6 MACHINE OUTLETS STATUS ...

Страница 36: ...ain to save the change To exit the setpoint setting press 3 Time setting Press to set the time Change the time using or Press to adjust the minutes using or After setting the time press again to exit the time setting menu 4 Timer setting ECONOMIC MODE Press for at least 2 seconds to activate the SCHEDULE PROGRAMMING mode Press for at least 5 seconds this will display the start and end times of the...

Страница 37: ...emperature probe settings and compressor consumption 3 settings for each phase of the compressor Use or to display the various settings The values shown refer to the following nomenclature T1 T2 T3 T4 T5 T6 Water inlet temperature Cool sensor 1 Defrost Probe Compressor 1 discharge temperature Sonda de Aspiración 1 Cool sensor 2 Defrost Probe Discharge probe 2 T7 T8 T9 T10 T11 T12 Aspiration Probe ...

Страница 38: ...UTIONS The installation start up and maintenance operations must be performed by qualified personnel This equipment should not be installed in inflammable or explosive environments The electrical power supply at the main circuit breaker must be switched off before any maintenance work is performed inside the machine It is mandatory to use personnel protection equipment such as goggles gloves etc d...

Страница 39: ...tomatic or circuit breakers Before connecting the equipment you must check that the electrical installation is disconnected and that there is no voltage between the power supply phases Connect the lead in wires to the machine s input terminal Connect the ground wire to the relevant terminal The provision of any legislation in force with respect to any electric lines against direct or indirect faul...

Страница 40: ... para realizar esta conexión vienen instaladas de fábrica La conexión tiene que ser hecha a medida que se ensamblan los módulos La conexión de tierra de protección se puede identificar mediante este símbolo never be operated without the water treatment pump running Do not interconnect timers or programmers that may leave the unit running after the water treatment pump has been switched off Do not ...

Страница 41: ...s or breakage in the hydraulic connections Do not force the PVC pipes when connecting the equipment to the hydraulic network This will prevent them from breaking or cracking 11 START UP PROCEDURE When setting up the electrical connections as well as the general power supply and voltage should be verified Check that the hydraulics are connected properly Give power to the equipment by connecting the...

Страница 42: ...uids made specifically for that purpose COMPRESSOR Compressor oil must be checked in those unit models provided with an oil viewer Make sure the crankcase heater works properly Verify that the compressor refrigerates adequately with the circulating gas verify the refrigerant charge Verify that the power consumption has not increased Verify that the compressor discharge pressure is not too high and...

Страница 43: ...performed by removing the drain plug on the side of the condenser FAN Verify the flows of the fan each year Clean the louvers of the fan as well as the protection grill regularly ELECTRICAL PANEL Check all electrical connections Verify that there is no over heating of the electrical terminals Check that the safety systems are working correctly Verify that the thermostat or main control operates co...

Страница 44: ... one Or you may take it to your local authority s disposal facilities The equipment is tagged with a symbol that has been cross over rubbish bin and this symbol means that it must be separated from other urban waste and collected separately Potential effects on the environment or human health of the hazardous elements it may contain PVC The most widely used plasticizing agent in applications of PV...

Страница 45: ... buyer notifies the seller during the Warranty Period the seller must repair or replace the Product bearing this cost wherever it may be deemed appropriate unless it may not be possible or disproportionate Whenever the Product is not repairable or may not be replaceable the buyer may request a proportional reduction in price or if the non compliance is significant the termination of the sale agree...

Страница 46: ... normal wear and tear of the Product With regard to parts components and or perishable or consumables such as batteries bulbs etc the documentation accompanying the Product will be followed where necessary The warranty does not cover those events where the Product I has been subject to abuse II repaired maintained or handled by unauthorised persons or III repaired or maintained with non original p...

Страница 47: ...6 57 OUTLET POWER kW 4 43 5 72 8 88 10 73 16 60 22 71 ERR 3 32 2 85 3 13 3 02 3 35 3 46 SOUND PRESSURE dbA d 70 70 70 70 70 70 dbA 5 m 65 65 65 65 65 65 GROSS WEIGHT kg 115 115 185 190 205 240 SIBERIA EF 4 EF 6 EF 8 EF 10 EF 15 EF 17 CODES 33301 33302 33303 33304 33306 33307 POWER SUPPLY 230 V 50 Hz I N 400 V 50 Hz III N CONDENSER TITANIUM COMPRESSOR SCROLL FANS UNITS Uds 1 1 1 1 2 2 TYPE CENTRIFU...

Страница 48: ... V 50 Hz I N 400 V 50 Hz III N CONDENSER TITANIUM COMPRESSOR SCROLL WATER FLOW m3 h 6 10 6 10 7 12 7 12 10 15 10 15 CONNECTION DIAMETER mm 50 50 50 50 63 63 Hot Water Pool 27 C Cool Water Pool 12 C Cool Water Pool 6 C SPECIAL INLET POWER kW 1 59 2 41 2 73 3 64 4 09 5 71 OUTLET POWER kW 5 72 8 88 10 73 13 46 16 60 22 71 ERR 3 57 3 60 3 68 3 70 4 06 3 98 SOUND PRESSURE dbA d 70 70 70 70 70 70 dbA 5 ...

Страница 49: ...14 64 EF 17 4 16 70 2x1 17 19 04 TABLE 5 MAXIMAL ELECTRICAL DATA SIBERIA CODES VOLTAGE WIRE MINIMUN SECTION POWER SUPPLY COMPRESSOR FAN TOTAL ALASKA V mm2 A A A EF 4 230 4 I N PE 11 40 4 60 16 00 EF 6 6 14 80 7 60 22 40 EF 8 400 2 5 III N PE 7 70 4 10 11 80 EF 10 2 5 7 70 3 50 11 20 EF 15 4 12 30 3 98 16 28 EF 17 4 16 70 3 98 20 68 TABLE 6 MAXIMAL ELECTRICAL DATA BERING CODES VOLTAGE WIRE MINIMUN ...

Страница 50: ...GRO BLACK ROJO RED VERDE GREEN AMARILLO YELLOW 5 0 8 7 PRESOSTATO ALTA 1 HIGH PRESSURE SWITCH 1 10 9 16 15 FLUJOSTATO FLOWSWITCH TERMICO VENTILADOR FAN THERMAL SWITCH T1 T2 95 96 REMOTO REMOTE ON OFF REMOTO REMOTE HEAT COOL MODO REMOTO ACTIV DESACT REMOTE MODE ON OFF R3 R2 R5 R4 R1 R0 HIGH PRESSURE COMP 1 TEMP SALIDA AGUA WATER OUTLET TEMP TEMP AMBIENTE AMBIENT TEMP TEMP ASPIRACION COMP 1 SUCTION ...

Страница 51: ...W PRESSURE SWITCH 1 FLUJOSTATO FLOWSWITCH REMOTO REMOTE ON OFF TERMICO VENTILADOR FAN THERMAL SWITCH REMOTO REMOTE HEAT COOL MODO REMOTO ACTIV DESACT REMOTE MODE ON OFF BOMBA FILTRACION FILTRATION PUMP VALVULA 4 VIAS 4 WAY VALVE RES CARTER CRANKCASE HEATER PRESOSTATO ALTA 1 HIGH PRESSURE SWITCH 1 PRESOSTATO BAJA 1 LOW PRESSURE SWITCH 1 FLUJOSTATO FLOWSWITCH REMOTO REMOTE ON OFF TERMICO VENTILADOR ...

Страница 52: ...C T S R RELE TÉRMICO THERMAL RELAY 96 NC RESISTENCIA DE CARTER CRANKCASE HEATER MAGNETOTERMICO CIRCUIT BREAKER CONTACTOR 2 1 6 COMPRESOR 1 COMPRESSOR 1 VENTILADOR 1 FAN 1 T1 95 N T 5 S R 3 1 6 T 4 2 S R 0 U1 V1 W1 T1 R1 S1 U3 V3 W3 4 3 2 1 380V 380V R S T N TARJETETA PCB MEDIDOR DE CONSUMO 1 CONSUMPTION METER 1 A B C CONTACTOR R T S N T2 RELE TERMICO THERMAL RELAY NC T S R RELE TÉRMICO THERMAL REL...

Страница 53: ...A 2019 ALL RIGHTS RESERVED PROPRIETARY DOCUMENT Pag 53 ENGLISH IMAGE 5 ALASKA DIMENSIONS CODES X Y Z ALASKA mm mm mm ALASKA 4 1460 80 512 746 ALASKA 6 1460 80 540 746 ALASKA 8 1610 80 540 846 ALASKA 10 1452 80 655 890 ALASKA 15 1807 80 708 866 ALASKA 17 1807 80 708 866 ...

Страница 54: ...4 1460 80 550 50 746 SIBERIA 6 1460 80 706 50 746 SIBERIA 8 1610 80 706 50 846 SIBERIA 10 1455 80 800 50 1434 SIBERIA 15 1857 80 900 50 1434 SIBERIA 17 1857 80 900 50 1434 IMAGE 7 BERING DIMENSIONS CODES X Y Z BERING mm mm mm BERING 4 1460 80 550 50 746 BERING 6 1460 80 550 50 746 BERING 8 1610 80 700 50 846 BERING 10 1610 80 700 50 890 BERING 15 1807 80 800 50 866 BERING 17 1807 80 800 50 866 ...

Страница 55: ...ectiva 2005 88 UE Directiva sobre restricciones a la utilización de determinadas sustancias peligrosas en aparatos eléctricos y electrónicos 2011 65 UE RoHS Directiva sobre residuos de aparatos eléctricos y electrónicos 2012 19 UE RAEE Real Decreto 208 2005 y 219 2013 sobre aparatos eléctricos y electrónicos y la gestión de sus residuos Reglamento relativo al registro la evaluación la autorización...

Страница 56: ...all aperto e la sua correzione con la direttiva 2005 88 UE Direttiva 2011 65 UE sulla restrizione dell uso di determinate sostanze pericolose nelle apparecchiature elettriche ed elettroniche RoHS Direttiva 2012 19 UE sui rifiuti di apparecchiature elettriche ed elettroniche RAEE Spagnolo Regio Decreto 208 2005 ed 219 2013 sulle apparecchiature elettriche ed elettroniche e la gestione dei loro rifi...

Страница 57: ...NU DE CE DOCUMENT SANS AVIS DE WIR BEHALTEN UNS DAS RECHT VOR DIE CHARAKTERISTIKA UNSERER PRODUKTE ODER DEN INHALT DIESES DOKUMENTS OHNE VORHERIGE ANKÜNDIGUNG VOLLSTÄNDIG ODER TEILWEISE ZU ÄNDERN CI RISERVIAMO IL DIRITTO DI MODIFICARE IN TUTTO O IN PARTE LE CARATTERISTICHE DEI NOSTRI ARTICOLI O CONTENUTO DI QUESTO DOCUMENTO SENZA PREAVVISO WIJ BEHOUDEN ONS HET RECHT VOOR OM DE KENMERKEN VAN DE ART...

Отзывы: