5.
EQUIPMENT INSTALLATION
These units are supplied fully assembled, with complete electrical wiring and its definitive charge
of refrigerant gas R407-C. Furthermore, every assembled machine has been put to the test inside
a test laboratory inside the manufacturing factory before shipping to clients.
The hydraulic circuit of the unit has been carefully drained to avoid residual water in the casing
of the evaporator and prevent any risk of corrosion in case of prolonged storage of the machine.
1.1.
SAFETY INSTRUCTIONS
Always ensure that Personal protective equipment is usd to protect personnel against hazards
that have an adverse effect on occupational health safety. Refer to paragraph
¡Error! No se
encuentra el origen de la referencia.
, pág
¡Error! Marcador no definido.
.
All the people in charge of the installation of the unit must have been instructed concerning the
unit security measures, thus interacting with the machine in a safe way and understanding the
hazards involved. Refer to paragraph
¡Error! No se encuentra el origen de la referencia.
pág.
¡Error! Marcador no definido.
1.2.
REQUIREMENTS AND PREVIOUS OPERATIONS
Todos los modelos:
•
Check the place where the equipment is to be located is strong enough to support the
weight of this.
•
To improve the distribution of weights, the unit will be placed on a bench according to
the designer's criteria.
•
Always place the machine in a vertical and level position
•
The equipment is designed to work:
o
ALASKA / BERING models: Outdoor installation.
o
SIBERIA / BERING models: Indoor installation.
•
A space must be provided around the equipment for its maintenance and operation, in
addition to checking that the air inlet and outlet are not obstructed.
•
It is not advisable to place the machine 1.5 meters above the sheet of water, or 3 meters
below.
•
During operation, condensation water produced by the evaporator may appear, for
which the machine has an evacuation outlet identified on one side.
This appliance must be installed and serviced by certified professionals, approved in
electrical, hydraulic and air conditioning domains.
For any questions regarding unit installation, please, take note of the machine model,
serial number, manufacture year, and contact us.