High and low pressure switches should be installed in the cooling circuit and verify the refrigerant
charge (Refrigerant Charge section).
To stop the equipment, disconnect switch on / off.
16.
PREVENTIVE MAINTENANCE
A record should be kept of each element repaired or substituted as well as of all maintenance
and repairs.
DISCONNECT THE EQUIPMENT FROM THE POWER SUPPLY before performing any
maintenance procedures.
The surface of the exterior panels may be cleaned with a soft cloth and non-abrasive cleaner.
The machine has been designed to work outdoors or indoors.
It is important to place the equipment on a stable and protected from flooding location.
WARNING:
in the case that the equipment will be shutdown for a long period of time, we
recommend you remove the equipment or periodically ventilate the area where the equipment is
located. This is because the humid and often corrosive (chlorinated) areas where the equipment is
located may lead to premature deterioration of the electrical components. The warranty does not
cover damage due to prolonged exposure to humid and corrosive atmospheres.
Aspects to consider:
CONDENSER BATTERY:
The units should be kept clean and free of obstacles which may hinder the circulation of air
through them. In order to clean them, use water (no pressure) and non-abrasive detergents or
cleaning liquids made specifically for them (consult the manufacturer).
COMPRESSOR:
Oil level must be checked on compressor models that include oil viewer.
Ensure that the Compressor casing resistance does work properly.
EVAPORATION UNIT:
Install the chemical doser at the exit of the equipment, as far as possible and under the exit level.
Never on the inlet of the equipment pump, thus would damage the evaporator unit.
Do not set concentrated chemical products in the skimmers that could attack the Titanium include
in the condenser.
In cold weathers where froze is usual, it is necessary to purge all the cleaning and heating
elements. In order to do that, the condenser includes a plug to purge it.
FAN:
Verify the flows of the fan each year.