AS64 series AC servo drive Control modes
-56-
DC12
–
24V
external power
BRK- 26
BRK+ 9
Motor
Brake
winding
Surge
absorber
Fuse (5A)
Emergency-stop
button
RY
DC24V
power
special for
brake
winding
Note: The brake winding must use independent 24V
power and cannot share the control power or relay
coil power.
+
-
+
-
Drive side
RY
RY
⚫
You must provide independent 24V power for the electromagnetic brake, which cannot use the
signal-control power.
⚫
In the figure,
RY
indicates relay coil. Pay attention to the diode direction.
⚫
The electromagnetic brake is used for holding but not for common stop.
⚫
Though the electromagnetic brake can prevent the falling of heavy objects or keep the falling
speed, you must install an external brake device.
4.6 Wiring description for CN5
Wiring for the second-encoder terminal circuit
Second encoder
Differential command
pulse input
EXA+ 3
EXA- 4
EXB+ 10
EXB- 9
EXZ+ 14
EXZ- 13
FG
5 EX5V
12 EX0V
EX0V
EX5V
CN5
Note: ( ) is shielded twisted pair.
EXU+ 6
EXU- 11
EXV+ 1
EXV- 7
EXW+ 2
EXW- 8