23
Astra P-8 USER MANUAL
stove must be removed. Before removing the top cover of the
stove, the display has to be taken out and disconnected. Work in
the following order:
1. Remove the frame of the display. Using thin vertical
screwdriver, locate two gaps in the left and the right side of the
plastic frame of the display. Turn the screwdriver inside those
gaps, gently separate the frame from the display (Fig. 17a).
2. Take out the display. Use a PH1 size cross screwdriver to
unscrew four screws fastening the case of the display. Lift the
display (Fig. 17a).
The display is connected to the controller
board by RJ11 type data cable. Do not forget to
disconnect the cable before taking out the display.
3. Remove the rooftop cover. Unscrew six M5 bolts in the top
rear side of the stove: three on the left and three on the right
side (Fig. 17b). Push the cover towards the rear panel of the stove
until its holders get loose (Fig. 17). Then lift the cover and remove
it.
4. Remove the lateral panels of the stove. Unscrew bolts
fastening the panels near the front grates at the top part of the
stove (Fig. 18a) and in the front and the rear sides of the base
plate of the stove. Raise the panels and remove them (Fig. 18).
5. Open all four the inspection hatches. Unscrew pairs of M5
bolts, remove gaskets and inspection lids (Fig. 18b). Clean the
flue channels in both sides of the stove.
• PELLET HOPPER PROTECTION AGAINST BURNING
The pellet hopper has a protection from overheating and burning: the temperature sensor 6 and the thermostat 12 (Fig.1). They
operate independently from the controller. If for any reason the hopper starts overheating the thermostat stops the stove by
interrupting the electrical supply.
To restart operation of the stove, remove the thermostat
cover 2 (Fig. 19) and depress the button behind it.
• PROTECTIVE HANDLE
Use this handle as a tool, when pulling the scraper’s
handle out of the front grate and removing the hot ashes
drawer. To pull out the drawer, hook the handle on a
ledge near the special notch (Fig. 20).
10. TROUBLESHOOTING
The stove display provides warnings for alerts and errors which can occur during the operation of the controller. The alarm icons
in the indicator line of the display signal a problem. An alert notification is indicated by blinking icons, errors are indicated with
continuously lit icons. In case of an alert, the combustion system remains operational. In case of an error, the combustion system has
malfunctioned seriously and is disabled. To solve the problem, a service technician should be contacted.
Each alert and error has a code which can be used to identify the problem. To display the code, press and hold the Cancellation button
for 3 seconds. If there is no information on the alert/error code, the screen shows ----.
Fig. 19
1. Protective handle; 2. Safety thermostat; 3. Electrical
supply switch.
1
2
3
Fig. 20.
Removing the hot ashes drawer.
Содержание P-8
Страница 2: ......