Astr
a Ope
ration Manu
al: E
spre
sso Mach
ine
s & Ste
ame
rs
p.
39
When boiler pressure on the gauge is between 15 and 20 PSI, you are ready to put the machine
into program mode. This procedure is used to program the desired temperature for automatic
steam wands. Your machine comes pre-programmed with the factory-suggested setting, 165
degrees Fahrenheit. Ensure that the machine is ON and LED displays the current temperature.
Each steam wand can be programmed and operated INDEPENDENTLY, however, it is
recommended that settings 2-6 be left on factory default for standard machine operation.
1
. Setting the Desired Steaming Temperature at Probe
(the desired temperature for the beverage)
• Press the “Set” button on the display.
• Display will read “Set.”
• Press “Set” button again.
• Display will read “165°F”.
• If you would like to change this pre-set temperature, press the up arrow to raise the
temperature. Press the down arrow to lower the temperature.
• Once you have selected the desired temperature, press the “Set” button.
• The display will show the sensor’s current temperature.
2
. Setting the Accuracy Tolerances
(Not Recommended)
(the level of acceptable variance on the programmed temperature)
• Press and hold the “Set” button.
• Display will read “Cor”.
• Press “Set” button again.
• Adjust the temperature between 0-20 degrees Fahrenheit using the up or down arrows
(default is set at 0 degrees Fahrenheit).
• Once you have selected the desired temperature, press the “Set” button.
* Example: variance of ±3°F for pre-set temperature of 165 degrees Fahrenheit =
162-168 degrees Fahrenheit.