www.astontechusa.com
15
Aston Magnetic Levitation Wheel Balancer AWB-139ML User’s Manual
The wheel balancer sets
standard dynamic
balancing as default mode. As shown in the picture,
the balancing mode indicator is in standard dynamic balancing mode, which shows clip on type
weights are to be fitted on both sides of the rim flange.
Operation steps
A
Set wheel data
A, W
and
D
.
B
Spin the wheel
PERATE
Lower the protection hood, the wheel spins automatically, as the wheel spins, all indicators and
display windows on the display panel are turned off until the wheel stops, the balancing results
are indicated on both weight display windows as illustrated in the picture followed.
Attention!
*
Do not apply any undue stress to the machine during wheel spin to obtain most
accurate result.
* Do not operate the machine without protection hood. Never raise the protection hood
before the wheel stopped. Keep hair, loose clothing, fingers and all parts of body
away from moving parts.
*
To terminate a spin process, press
STOP
key.
C
Raise the protection hood.
D
Weight position search. Two methods are available in this machine: Manual search
and Automatic search
(SPL)
, the user can choose one of them during operation.
MANUAL POSITION SEARCH
STEP 1
. To search first weight position (i.e. INNER (left) side), rotate the wheel with hand,
as indicates on the weight position indication bar, turn the wheel backward (reverse spin
direction) or forward (spin direction) until all lights of the indication bar are illuminated, hold
the wheel for about 1 second, the locking device activated to restrain the wheel in the position.