Connector Utilization
J3
Drives 1-4
J4
Drives 5-8
J5
Host connector
J6
Drives 9-12
J7
Drives 13-16
J8
Drives 17-20
J9
Drives 21-24
Enclosure Services Header
The Enclosure Services Header provides connectivity for GPIO-type enclosure
services on J34. Additional information on SCSI Enclosure Services is located in
the Other Connectors
Other connectors not listed above are reserved for Astek use or for future use.
SCSI Enclosure Services (SES) Section.
Pin
Signal Name
Pin
Signal Name
1
GND
2
GND
3
GPIO1
4
Switch (Crypto Erase)
5
3.3V
6
3.3V
7
GND
8
LED Sink (Crypto Erase)
9
GND
10
GPIO4
11
GND
12
HDD Fault LED
2
13
GND
14
No Connect
15
GND
16
Power Fail
1
1
5V tolerant input.
2
A 220
current limiting resistor is included on the A33606-PCI-60-6A. Therefore, an external current
limiting resistor is NOT required.
Power Fail Input
The Power Fail Input is a 5V tolerant input dedicated to indicate that a Power Failure has occurred. Many
times, this indicates that one of the redundant supplies has reported a failure or has stopped functioning.
When this signal is asserted high, the following events occur:
The enclosure fault LED is asserted on the front panel of the A33606-PCI-60-6A.
The Power Fail LED signal is turned on.
The FAIL bit in the power supply SES element is asserted.
The status of the power supply SES element is changed to CRITICAL.
The status of the enclosure SES element is changed to CRITICAL.