VLM60 User Manual
Parameterization
page 24
ASTECH GmbH
Store
The command permanently saves the currently set parameters in the device. The command is protected by a
password (command
Password
).
store
Only if this command is executed, the current parameter settings are retained even after the device is
switched off.
TComp
The command outputs the value for the temperature compensation in PPM/K. The compensation value is
used for a temperature-independent determination of the velocity.
tco
mp
The setting is made at the factory and cannot be changed.
Testmeasure
The command starts a test output of the measured values. This output has a fixed structure and is composed
of the values x-speed, y-speed, x-length, y-length, measuring rate, illuminance, overexposure and
underexposure. The output ends automatically after 60s.
testm
easure [c]
c = c (no abort after 60 s)
Sending ESC to the device aborts the test output. Unlike other commands, the line termination here is only a
"CR" (carriage return).
When using the VLMTool, the output values are shown in a window display.
Type
The command outputs the type of the connected VLM60.
type
The setting is made at the factory and cannot be changed.