Parameterization
VLM60 User Manual
ASTECH GmbH
page 17
Examples
so1format v ' m/s'
velocity and String
“
m/s
”
, CR LF
2.52 m/s
so1format v:x,' ',r
x-velocity, SPACE, measurement rate, CR LF
1.27 94
so1format v 20 r
velocity, SPACE, measurement rate, CR LF
2.52 94
so1format v*60,' m/min;',l,' m'
velocity, m/min, length, m, CR LF
151.2 m/min;6.7 m
so1format l*10+12.345
length in dm + offset (input in dm)
79.456
so1format s t l:h 10
special format
s
, length hexadecimal and LF
00013b 05e 0000029f
so11format 72 97 108 108 111
for string in ASCII-input
Hallo
so1format v 13 10
velocity and additional CR LF
2.52
SO1Interface
Serves for the configuration of the programming interface S1. The baud rate, protocol type, parity and flow
control are set. The setting can be made for each switch individually or for all switches simultaneously. The
order of the switches does not matter. Switches that are not specified will not be changed. The format is fixed
with eight data bits and one stop bit. When parity is enabled, the eighth data bit is replaced by the parity bit.
so1i
nterface
[n] [c] [c] [c]
(n = baud rate, c = protocol, parity, ...)
default: 115200 N D
Switch
Meaning
9600
baud rate 9600 (or 19200; 38400; 57600; 115200)
'-'
no protocol
'N'
no parity
'O'
odd parity
'E'
even parity
'D'
full duplex
SO1On
Serves to switch on and off the data output on the programming interface S1.
so1on
[n]
n = 0 (off), 1 (on)
default: 0
During command input and processing the output of the data is interrupted!
SO1Sync
Serves for setting the output update on the programming interface S1. It can be set whether the output should
be synchronous to a selectable time interval (command
SO1Time
) or at an event at the switching input
(TRIGGER).
so1sy
nc
[n]
n = 0, 1
default: 0
0
Time-synchronous. The update is synchronous to the time interval SO1Time.
1
Trigger synchronous. Updating is synchronous to the clocking at the switching input (TRIGGER).