background image

 

 

 

USE THIS SECTION FOR BATTERY 
TESTING IF YOUR 12/24 VOLT SYSTEM 
LOOKS SIMILAR TO THIS:

 

 

One six volt battery by itself cannot be tested with this unit.  It 
will not provide enough voltage under load to allow the digital 
circuitry to work. 

 

Please note: When two six volt batteries are connected in 
series, the voltage of the array is 12.  The CCA rating of the 
series does not double.  It is the same CCA as either of the 
individual batteries.  (If you have two, 500 CCA, 6 volt batteries 
in series, it is equivalent to a 500 CCA, 12 volt battery and 
should be tested with a 250 amp load.) 

 

Both the heavy duty and light gauge leads will be used in this 
test (see figure 5). 
1) 

Attach the positive heavy duty lead to the positive terminal 
of Battery 1 and the negative heavy duty lead to the 
negative terminal of Battery 2.  Connect the external 
voltage leads; red lead to positive terminal of Battery 2 and 
the black lead to the negative terminal of Battery 2. 

2) 

Proceed with the battery test.  After the test evaluate the 
results.  If the battery group as a whole does not pass then 
press the down arrow button to read the minimum voltage 
on Battery 2.  See the table below for the minimum 
voltages of a 6 volt battery. 

3) 

To determine the battery voltage of Battery 1 just subtract 
the external voltage reading from the minimum overall 
voltage.  

4) 

If the battery voltage on Battery 2 looks good but the 
overall battery voltage is too low, check the jumper 
voltage.  This is done by repeating step 1 but connect the 
external voltage leads across the jumper, positive lead to 
negative terminal of Battery 1 and negative lead to the 
positive terminal of Battery 2.  After testing read the 
external voltage it should be less than 0.2V. 

 

 

BATTERY TEMPERATURE COMPENSATION 15 SECOND LOAD 

TEST 

 

°C 

 

21

 

 

10 

 

 

-4 

 

-9 

 

-15 

 

°F 

 

70

 

 

50 

 

35 

 

25 

 

15 

 

 

MIN. 

VOLT 

 

4.8 

 

4.7 

 

4.6 

 

4.5 

 

4.4 

 

4.3

 

 

 

Please note that the test described above is not the easiest way 
to run a test on two batteries in series, but it is the most 
accurate.  If you were to test the batteries and take only one 
voltage reading from the positive terminal of Battery 1 to the 
negative terminal of Battery 2, there are problems that could 
remain hidden or cause excessive replacement costs. 

 

BLACK
LEAD

BATTERY 4

BATTERY 1

BATTERY 3

6V

6V

+     -

6V

FIGURE 5

+     -

+     -

BATTERY 2

RED

LEAD

6V

+     -

+

-

 

 

The voltage reading under load from the positive terminal of 
Battery 1 to the negative terminal of Battery 2 is the sum of the 
voltage drops across Batteries 1, 2, and the cable jumper. 

 

Total voltage = B1 v B2 v jumper voltage drop 
(see figure 6). 

 

If you had two good batteries and a bad jumper connection, the 
total voltage may be less than acceptable.  If the batteries were 
replaced, the new ones may test bad due to the bad 
connection.  Replacing or cleaning a bad jumper cable is 
cheaper and easier than replacing batteries if that is all that is 
needed. 
In another situation, you may have one good battery, a good 
jumper connection, and one bad battery.  If the good battery 
voltage is high enough to offset the bad battery voltage, you will 
have no indication of the potential problem.  If the good battery 
voltage is not high enough to offset the bad battery voltage, the 
group may test bad and both batteries replaced when only one 
of the needs to be. 
 

 
 

 

TESTING 24 VOLT SYSTEMS:

 

 

 

24 volt batteries may 

not

 be load tested with this unit.  Most 24 volt 

systems are made up of 2 12V batteries.  See above for testing. 

 

The unit is capable of testing 24 volt alternator and the starting 
systems. 

 

JUMPER

FIGURE 6

B1 VOLTAGE

6V

6V

BATTERY 2

+     -

BATTERY 1

+     -

B2 VOLTAGE

FIGURE 7

LO

AD

  T

ES

T

NO

+     -

24 VOLT

Содержание BEST 6044

Страница 1: ... actuated and serves as a reminder to not disconnect leads while load is on AMPS meter reads both and amps for easy diagnosis of leakage current problems Unit monitors the voltage ripple letting you know when alternator output diodes have failed The electronic circuits are protected against reverse voltages caused by connecting leads incorrectly The electronic circuit board has a protective coatin...

Страница 2: ...rking with a lead acid battery A lead acid battery can produce a short circuit current high enough to instantly weld a ring or the like to metal and cause severe burn 5 Spilled acid Neutralize with a solution of baking soda 1 pound per gallon of cold water or household ammonia 1 pint per gallon of cold water VEHICLE SAFETY 1 Keep your body clothing and test leads away from all moving parts of the ...

Страница 3: ...esent open circuit battery voltage If the minimum voltage was below 9 6V then it will also flash Bd The minimum acceptable voltage for a battery at the different temperatures is as follows BATTERY TEMPERATURE COMPENSATION 15 SECOND LOAD TEST C 21 16 10 4 1 7 12 18 F 70 60 50 40 30 20 10 0 MIN VLT 9 6 9 5 9 4 9 3 9 1 8 9 8 7 8 5 If the CCA of the battery is not known check vehicle manufacturer s re...

Страница 4: ...it should be less than 0 2V BATTERY TEMPERATURE COMPENSATION 15 SECOND LOAD TEST C 21 10 2 4 9 15 F 70 50 35 25 15 5 MIN VOLT 4 8 4 7 4 6 4 5 4 4 4 3 Please note that the test described above is not the easiest way to run a test on two batteries in series but it is the most accurate If you were to test the batteries and take only one voltage reading from the positive terminal of Battery 1 to the n...

Страница 5: ...re the lead from the battery terminates 2 3 Start the vehicle press the up arrow this will display the maximum differential external voltage reading during the starter test 4 Repeat the same procedure checking the voltage drop across the solenoid negative lead to starter side of solenoid 2 to 3 5 Repeat again checking the voltage drop between the solenoid and the starter Positive lead at solenoid ...

Страница 6: ...wing steps 1 Make sure the differential voltage leads and the amp probe are not connected The 6044 zero s these two items on power up so any voltage reading on them now will be considered zero 2 Connect the unit to the battery see figure 10 3 Connect install Differential Voltage leads and Amp Probe into there respective jacks Amp probe should not be around any cables at this time this would cause ...

Страница 7: ...wer up if a voltage or current is present at this time then those values are considered zero and can cause errors in further readings by those devices items The zero value can be checked by installing the amp probe and pressing the zero button and connecting the differential leads and then shorting them together then placing the unit in the display mode This is done by pressing Select Test 2 until...