background image

5

Exiting Learn mode:

• 

Press the Siren Learn button to exit the learn mode

 

  

The PIR and Door Contact may trigger the Siren at this 
point.

 (Do not turn the siren power off.)

Disarming Siren:

  

Press disarm followed by 0000.

 

  (The siren will beep and flash twice.)

Adjusting Alarm ringing duration:

• Dip switch 3 determines the alarm ringing duration 

length. Switch left for 4 minutes or right for 10 
minutes (default) siren duration.

Enable/disable interference detection:

• Set Dip switch 2 for interference detection. Switch 

left to enable and right to disable (default).

Programming is now finished and the system is
ready to be installed.

Entering Learn mode:

• Press and hold  

Siren learn button

   for 1 second.

  (A short beep will follow with the outside LEDs flashing once.)

 

Adding devices:

  Keypad 

(All keys should be pressed in quick succession.)

 

1

 Press 

Panic button A

 and enter 

pincode

 (please 

note that the default pincode is 0000).

 

(The LED will now be flashing. System is now in setting mode) 

 

   2

 Press  

Panic button A

  and enter 

8

 

(The keypad will confirm with two fast flashes that it is in “Siren 
as master” mode.) 

   3

 Press  

Panic button A

  then 

1

 to send learn-in 

signal.

 

4

 Press Panic button A then 2. The press disarm 

twice to quit. 

(The siren will beep in acknowledgment).

 

(The keypad LED will now stop flashing. If not, press “disarm” 
twice again) 

Programming the Siren-based system 
(without control panel)

3

The siren is the heart of the system. All components must be recognised by the siren.

2

 

1

 

System is now in learning mode for 3 minutes. 
Proceed to the following steps to add in 
additional devices (20 devices maximum) within 
this time period.

If device learning takes more than 3 minutes and 
the learn mode expires, the siren learn button will 
need to be pressed again to add more devices.

i

When any device is learnt-in, the siren will beep 
once and the outside LEDs will flash once in 
acknowledgement.

Remember to press any buttons and keys firmly 
for 1 second to send a learn-in radio signal.

i

3a

4

 

5

This unit is equipped with the latest type of 
radio receiver using AM radio technology. If the 
system is armed any criminal attempt to interfere 
detector transmissions will trigger an alarm. 
If the alarm is frequently triggered by interference 
there may be high levels of unusual radio signals 
in your area. Some kinds of electronic equipment 
can generate this kind of radio interference. 
In the unlikely event of you experiencing problems 
with interference, it is recommended that you 
switch interference detection off. 

i

 

 

ale

Y

R

1

2

3

6

5

4
7

8

9

0

Battery

cover

Coin

slot

Locked

Unlocked

Yale

PRESS

PRESS

PRESS

PRESS

PRESS

3b

Содержание Yale HSA6060

Страница 1: ...y change is required Entry Exit feature for System with remote keypad The system has a 20 second entry exit time This feature allows you time to leave the home when arming the system Upon entering the feature allows time to disarm the system without causing an alarm Take care of your safety Display extreme caution when using ladders or steps please follow manufacturer instructions Be careful when ...

Страница 2: ...ble from the outside of the premises Mount at chest height for ease of use Designed for indoor use only Help button accessory The help button provides extra protection for you and your family When help is needed the button can activate your alarm immediately even when the system is disarmed Mount on bedroom wall or by the front door Not clearly visible to an intruder Easily accessible Out of reach...

Страница 3: ... lid 2 Square siren only remove the left hand cover not battery compartment 3 Move the programming switches to Master On switch 4 and Clear On switch 1 4 Switch the power switch to on The 3 strobe LEDs will now flash side to side with one short beep 5 Move the Clear switch to the Off position PIR movement detectors 1 Pull out the plastic pull tab on the back of the PIR This will activate the batte...

Страница 4: ...rn Test button Learn Test button On Off switch Help button accessory 1 Remove the cover by loosening the fixing screw and insert the 12V battery supplied as shown Please ensure you observe battery polarity Door window contacts 1 Remove the cover of each door window contact by loosening the fixing screw 2 Insert two AAA batteries into each detector as shown The indicator LED will flash briefly 7 Ke...

Страница 5: ...it The siren will beep in acknowledgment The keypad LED will now stop flashing If not press disarm twice again Programming the Siren based system without control panel 3 The siren is the heart of the system All components must be recognised by the siren 2 1 System is now in learning mode for 3 minutes Proceed to the following steps to add in additional devices 20 devices maximum within this time p...

Страница 6: ...a location where the device is to be mounted see section Location Planning for suggestions Mounting the Keypad 1 Drill holes into the wall using the fixing slots as a template Before mounting it is important to disable the system tamper to avoid the siren sounding an alarm i The tamper function is now disabled for one hour If more time is required simply repeat the above step i Before you make the...

Страница 7: ... be placed on the frame Windows can be protected in a similar way to doors Make sure the tamper switch spring is fully depressed Mounting using adhesive pads 1 Clean the mounting surface with a suitable degreaser agent 2 Remove the protective film from one side of the adhesive pad and apply to the back of the sensor and magnet 3 Remove the remaining protective film and firmly press into place 4 Te...

Страница 8: ...Help button 1 Break through the knockouts where the plastic is thinner 2 Using the holes as a template drill holes in the surface and insert wall plugs if fixing into plaster or brick Screw the rear case to the wall 3 Replace the cover and tighten the screw Mounting the Smoke Detector 1 The base has two mounting slots Using the slots as a template drill holes and insert the wall plugs if fixing to...

Страница 9: ...system and opening protected doors windows and walking past PIRs Now s the time to set your pin code and show the rest of the family how simple it is to use 5 Keypad will arm the system with a 20 seconds exit period All detectors will be ignored except for the tamper switches The system can be armed when inside the protected area of your premises Keyfob will arm the system instantly without a 20 s...

Страница 10: ...then change the batteries Recalibration The smoke detector might need recalibrating after time to ensure it is working at its optimum This is done by pressing and holding in the test button until the LED flashes and it beeps after 10 seconds The detector will then start its self calibration routine Keypad Modes Table 1 KeyFob Modes Table 2 Please note that silencing the alarm with the help button ...

Страница 11: ...been learnt in press and hold the Disarm button to quit learn mode 5 Press the Arm and Emergency buttons together and continuously for 5 seconds until the LED stops flashing to rearm tamper protection Adding devices to an already installed system The installed system will be controlled by either a keyfob s or a keypad s Keypad 1 Enter Setting mode Press Panic button A followed by the pincode Indic...

Страница 12: ...rotection as described in section 4 2 Loosen the case screw and remove door window sensor from base to reveal battery 3 Using a screwdriver gently lever out the old battery 4 Insert new CR2032 coin cell with the side uppermost 5 Press battery into holder firmly with finger and thumb until a click is heard 6 Refit sensor on base and tighten bottom case screw Switch tamper protection back on Door wi...

Страница 13: ...050 HSA6060 HSA6080 HSA6090 HSA6091 HSA3045 HSA3070 Date 16 11 06 On behalf of ASSA ABLOY Ltd ASSA ABLOY Ltd School Street Willenhall West Midlands England WV13 3PW John Ward Director 17 Model HSA3400 HSA3020 HSA3060 HSA3010 HSA3050 HSA3045 HSA3080 HSA3030 HSA3070 EN 300 220 1 V2 1 1 2006 04 EN 301 489 1 V1 6 1 2004 12 EN 301 489 3 V 1 4 1 2002 08 EN 60 950 2001 A11 corrigendum 2004 ...

Страница 14: ...ower supply 4 5V 3 x AAA alkaline cells 2 years typical domestic service life 1 minute sleep timer Movement detection range 15m 110 Door window contact Radio Microprocessor controlled 433 92MHz AM transmitter Power supply 3V CR2032 lithium coin cell 2 years typical domestic service life Smoke detector Radio Microprocessor controlled 433 92MHz AM transmitter Power supply 6V 4 x AAA alkaline cells 3...

Страница 15: ...will now have to be re learnt into the Siren see either Programming the siren based system or Adding accessories sections PIR PIR does not respond to movement Previous movement has triggered the PIR sleep timer see page 7 is preventing subsequent movement detection Arm system and vacate protected room for at least 1 5 minutes before testing PIR is slow to respond This is normal the PIR has sophist...

Страница 16: ...ion Can vary depending on building construction and RF environment Radio Microprocessor controlled 433 92MHz AM transmitter Power supply 12V 23A MN21 alkaline miniature lighter battery 3 years typical domestic service life 0560 18 All devices EMC Tested to ETS 300 683 Radio Components tested to EN 300 220 1 Environmental conditions 10 C to 40 C relative humidity 70 non condensing for all units exc...

Отзывы: