background image

For technical support contact Yale

®

 at 800.438.1951 or [email protected]

An ASSA ABLOY Group brand

9

80-9470-0162-000 10/18

Delayed Egress

Exit Device

Installation Instructions

Copyright © 2018, ASSA ABLOY Access and Egress Hardware Group, Inc.  

All rights reserved. Reproduction in whole or in part without the express written 

permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.

7

Non-ElectroLynx Door Prep

Figure 8 

NOTE:
1.  Do not scale drawing.
2.  Dimensions are in inches (mm).
3.  LHR H.M. opening shown. Details are 

typical for all opening materials (both 

hands).

4.  This preparation is an addition to 

preparation shown on device template.

5.  See device template to locate 

centerline of device template.

6.  Shields for wring access 

recommended for insulated and 

composite doors.

7.  Locate and prepare wiring access 

holes when installing device.

Exit Device

7100 Series

7200 Series

Dim. A

2-5/16 (59)

1-11/16 (43)

Содержание Yale Delayed Egress

Страница 1: ...le codes and ratings Installation Instructions For technical support contact Yale at 800 438 1951 or support yalelocks com 80 9470 0162 000 10 18 An ASSA ABLOY Group brand Available on the following devices Rim Mortise SquareBolt Concealed Vertical Rod Surface Vertical Rod Rod Guards Required made by other manufacturers Copyright 2018 ASSA ABLOY Access and Egress Hardware Group Inc All rights rese...

Страница 2: ... written permission of ASSA ABLOY Access and Egress Hardware Group Inc is prohibited 1 3 2 4 TOC Table of Contents Panic and Fire Rated Devices 3 End Cover and P C Board Assembly 4 Installation of End Cover Assembly to Device 5 ElectroLynx Connector System for All Electrical Installation 6 Device Mounting 7 Wiring Layout and Jumper Settings 8 Non ElectroLynx Door Prep 9 Wiring Diagram Single Door ...

Страница 3: ...rs in Figure 1 1 Delayed Egress Exit Device 2 24VDC UL Listed Regulated and filtered Power Supply with Fire Alarm Interface Recommend Securitron BPS 24 1 or 24 2 UL294 Listed depending on your requirements Power supply is NOT to be used in UL603 Burglar Alarm System 3 Power transfer UL or Ulc listed 2 10 wire depending on system Securitron EPT or equivalent 4 Sign MUST BE INSTALLED ON DOOR ABOVE D...

Страница 4: ...e of cylinder nut into arming switch activator to allow rotation of activator 6 Tighten cylinder nut on mortise cylinder and to secure circuit board assembly 7 Verify assembly by rotating key counter clockwise and clockwise Key should move freely and arming switch should trip for both rotation directions If key does not rotate freely verify cylinder nut was placed in correct orientation If arming ...

Страница 5: ... J8 Reset Delay Figure 3 Jumper on 10 seconds Default Jumper off 20 seconds 3 Slide end cover assembly into exit device Figure 3 Do NOT pinch or crimp wires Figure 3 4 Connect device lock assembly to Connector J1 Figure 4 5 Place wire connectors and excess wire between end cover and circuit board Figure 4 Check all connections before proceeding J5 J8 Connector J2 To Power Transfer Hinge Connector ...

Страница 6: ...ss on hinge as required by using connectors allowed by local code Plug pigtail harness connector into electric hinge connector Feed harness through frame prep and mount electric hinge B If wiring later plug pigtail harness connector into electric hinge connector Feed harness through frame prep and mount electric hinge NOTE 1 Wiring to pigtail harness is per facility wiring requirement 2 For an Ele...

Страница 7: ...E Switch contact rating 5A 28VDC Wire must be protected from abrasion For use with Class II circuits only LHR Installation with O Monitor Shown End Clamp Power Transfer Hinge Wire Access 3 4 Dia hole on same centerline as device Inside face only End Cover Installed 4 TAN NC 3 PNK NO 2 C GRY O Monitor Connections Pigtail harness with 4 pin connector Pigtail harness with 8 pin connector 1 7 5 6 4 3 ...

Страница 8: ...cked state for normal device operation Device must be rearmed by resetting from remote reset on device 8 5 Output Orange Secure Relay Output Normally closed NC contact that changes to normally open NO when device has released 5 6 Output Blue Secure Relay Output Normally open NO contact that changes to normally closed NC when device has released 6 7 Output Green Alarm Relay Output Normally open NO ...

Страница 9: ... and Egress Hardware Group Inc is prohibited 7 Non ElectroLynx Door Prep Figure 8 NOTE 1 Do not scale drawing 2 Dimensions are in inches mm 3 LHR H M opening shown Details are typical for all opening materials both hands 4 This preparation is an addition to preparation shown on device template 5 See device template to locate centerline of device template 6 Shields for wring access recommended for ...

Страница 10: ...is prohibited 8 Wiring Diagram Single Door Exit Only Operation Monitoring Red LED indicates device is armed and secure Activating device will sound horn Green LED will illuminate after 15 seconds Device will release for exit unsecure Figure 9 C NC FIRE ALARM Delayed Egress Device GND 24V ALR N C WHT ALR N O GRN SEC N O BLU SEC N C ORN BYPASS YEL RESET BRN 24V RED GND BLK Connector 2 GND BLK DPS BL...

Страница 11: ...SECURITY PACKAGE MECHANICAL TRIM ENTRY WITH EXTERNAL DOOR POSITION SWITCH SINGLE DOOR WITH REMOTE INPUTS AND MONITORING OUTPUTS For added security cut the YELLOW wire on CONNECTOR J1 and attach it ALR N C WHT ALR N O GRN SEC N O BLU SEC N C ORN BYPASS YEL RESET BRN 24V RED GND BLK Connector 2 GND BLK DPS BLU POWER RED NC NC LOCK WHT RED LOCK WHT TRIGGER SW YEL WHT TRIGGER SW YEL Connector 1 GND Co...

Страница 12: ...s mode Bypass Maintained Egress Mode Figure 16 1 Rotate key clockwise return key to center position and remove 2 Red LED will flash slowly 3 Device is disarmed acting as a standard exit device which allows free egress Resetting device from Bypass Mode to Delayed Egress Mode Figure 16 1 Rotate key counter clockwise return to center position and remove 2 Solid red LED will illuminate 3 Device will b...

Страница 13: ...l open door without affecting device in an armed condition refer to wiring diagrams for wiring Outside Trim Monitor Switch O Suffix This option is used when outside trim is desired to be used with security package or an external Door Position Switch made by other manufacturers This switch will allow bypass disarm device when trim is used for ingress Device will need to be reset upon entry by means...

Страница 14: ...with Security Package CVR or Mortise Units with Door Position Switch Check trigger mechanism wire harness on circuit board and all other connections Check pushpad activating switch in device Make sure strike magnet is installed and aligned Check by removing device latchcase cover close door and align magnet until unit arms Make sure DPS is wired normally closed with doors closed into trigger wire ...

Страница 15: ...15 80 9470 0162 000 10 18 Delayed Egress Exit Device Installation Instructions Copyright 2018 ASSA ABLOY Access and Egress Hardware Group Inc All rights reserved Reproduction in whole or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group Inc is prohibited NOTES ...

Страница 16: ...rdware Group Inc All rights reserved Reproduction in whole or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group Inc is prohibited For technical support contact Yale at 800 438 1951 or support yalelocks com 80 9470 0162 000 10 18 An ASSA ABLOY Group brand Yale Locks Hardware Product Support Tel 800 438 1951 www yalelocks com ...

Отзывы: