Delayed Egress
Installation Instructions
Exit Device
Copyright © 2018, ASSA ABLOY Access and Egress Hardware Group, Inc.
All rights reserved. Reproduction in whole or in part without the express written
permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
8
Wiring Diagram - Single Door Exit Only
Operation Monitoring
Red LED indicates device is armed and secure.
Activating device will sound horn. Green LED will
illuminate after 15 seconds. Device will release for
exit (unsecure).
Figure 9
C
NC
FIRE ALARM
Delayed
Egress
Device
GND (-)
24V (+)
ALR N/C
WHT
ALR N/O
GRN
SEC N/O
BLU
SEC N/C
ORN
BYPASS
YEL
RESET
BRN
24V (+)
RED
GND (-)
BLK
Connector 2
GND (-)
BLK
DPS
BLU
POWER (+)
RED
NC
NC
LOCK
WHT RED
/
LOCK
WHT
TRIGGER SW
YEL WHT
/
TRIGGER SW
YEL
Connector 1
Connector J1
Wire Transfer
Hinge
SECURITRON BPS
POWER SUPPLY
24V (+)
GND (-)
NEUTRAL
EARTH
ALARM
ALARM
120 VAC